Analisa Pengaruh Tekanan Vakum Terhadap Laju Perpindahan Panas dan Efektivitas Kondensor pada PLTU Blok III PT.PJB UP Gresik

Oktaviasari, Friska Putri (2018) Analisa Pengaruh Tekanan Vakum Terhadap Laju Perpindahan Panas dan Efektivitas Kondensor pada PLTU Blok III PT.PJB UP Gresik. Diploma thesis, Institut Teknologi Sepuluh Nopember.

[thumbnail of 10211500000043-Non_Degree.pdf]
Preview
Text
10211500000043-Non_Degree.pdf - Accepted Version

Download (5MB) | Preview

Abstract

Kondensor merupakan salah satu jenis heat exchanger yang berfungsi mengkondensasikan fluida gas menjadi cair. Kondensor adalah komponen utama pada siklus PLTU yang menjadi penyebab terbesar terjadinya losses pada siklus dan dapat mempengaruhi efisiensi suatu pembangkit. Jika laju perpindahan panas rendah, mengakibatkan kerja netto akan semakin meningkat. Mengetahui peran kondensor sangat penting dalam suatu siklus, maka perlu dilakukan analisa pengaruh tekanan vakum terhadap laju perpindahan panas dan efektivitas kondensor Unit 3 PT. PLTU UP Gresik. Dengan melihat variasi tekanan vakum yang ada.
Data yang diambil dari tugas akhir ini adalah data rata-rata aktual per bulan selama 1 tahun. Metode perhitungan untuk analisa pengaruh tekanan vakum terhadap laju perpindahan panas dan efektivitas adalah Log Mean Temperature Different (LMTD) dan Effectiveness – Number of Transfer Unit (NTU).
Dari hasil perhitungan, didapatkan nilai efektivitas tertinggi terjadi pada tekanan vakum yaitu 0,06854 bar dengan efektivitas sebesar 0,9945. Sedangkan nilai effektivitas terendah terjadi pada tekanan vakum 0,08090 bar dengan efektivitas 0,9905. Didapatkan semakin kecil tekanan vakum di dalam kondensor, menghasilkan efektivitas kondensor yang lebih baik. Hal tersebut sebanding dengan laju perpindahan panasnya.
================================================================= Condenser is one type of heat exchanger that serves to condenser gas fluid into liquid. The condenser is the main component of the power plant cycle which is the biggest cause of losses in the cycle and can affect the efficiency of a plant. If the heat transfer rate is low, the net work will increase. Knowing the role of condenser is very important in a cycle, it is necessary to analyze the effect of vacuum pressure on the rate of heat transfer and condenser effectiveness Unit 3 PT. PLTU UP Gresik. By looking at the variations in available vacuum pressure.
In this final project, data taken the average of actual condition condenser per month for 1 year . Whereas, the method
calculation of analysis of the effect of vacuum pressure on heat transfer rate and effectiveness are Log Mean Temperature Different (LMTD) and Effectiveness - Number of Transfer Unit (NTU).
From the calculation results, obtained the highest effectivity value occurs at a vacuum pressure of 0.06854 bar with the effectiveness of 0.9945. While the lowest effectivity value occurred at 0.08090 bar vacuum pressure with effectiveness 0.9905. The smaller the vacuum pressure inside the condenser, resulting in better condenser effectiveness. This is proportional to the rate of heat transfer.

Item Type: Thesis (Diploma)
Additional Information: RSMI 621.402 5 Okt a
Uncontrolled Keywords: Condensor, Vacum Pressure, Heat Transfer Rate , Effectiveness
Subjects: T Technology > TJ Mechanical engineering and machinery > TJ263 Heat exchangers
Divisions: Faculty of Vocational > Mechanical Industrial Engineering
Depositing User: Friska Putri Oktaviasari
Date Deposited: 17 Dec 2020 02:43
Last Modified: 17 Dec 2020 02:43
URI: http://repository.its.ac.id/id/eprint/57605

Actions (login required)

View Item View Item