Material akustik sering dipakai untuk memperbaiki suatu ruangan dari cacat akustik. Cacat akustik yang susah untuk diperbaiki pada frekuensi rendah. Salah satu material yang dapat digunakan untuk memperbaiki cacat akustik ini adalah panel resonator. Namun resonator biasa hanya memperbaiki pada frekuensi rendah saja. Sedangkan Sonic Crystal yang dapat memperbaiki bunyi pada frekuensi yang diinginkan. Pada umumnya Sonic Crystal yang digunakan terbuat dari besi atau aluminium. Pada penelitian ini digunakan pipa resonator yang terbuat dari pipa PVC dengan bentuk setengah silinder. Adapun variasi panel yang digunakan adalah, ukuran 1,5”, 2”, dan 2,5” dengan panjang pipa 60 cm. Pengukuran dilakukan pada ruang semianechoic laboratorium Fisika Akustik, departemen Fisika FIA ITS. Metode yang digunakan dalam pengujian berdasarkan metode yang ditulis oleh C. Lagarrigue. Hasil pengukuran yang diperoleh frekuensi resonansi untuk pipa 1,5” adalah 24 titik frekuensi dan bandgap utama antara 817,5 Hz – 819,5 Hz dengan atenuasi maksimum -11,70 dB. Ukuran 2” adalah 27 titik frekuensi dan bandgap utama antara 800 Hz – 841,5 Hz dengan atenuasi maksimum -8,25 dB. Ukuran pipa 2,5” adalah 41 titik frekuensi dan bandgap utama antara 546,5 Hz – 630 Hz dengan atenuasi maksimum -14,41 dB. Dari hasil pengukuran tersebut terlihat bahwa perubahan ukuran pipa berakibat pada bertambahnya jumlah titik yang beresonansi dan bandgap utama terjadi pada frekuensi menengah yaitu antara 500 Hz – 800 Hz.=================================================================================================
Acoustic material is often used to repair a room from acoustic defects. Acoustic defects are difficult to repair at low frequencies. One of the materials that can be used to correct this acoustic defect is the resonator panel. However the ordinary resonator only fixes at low frequencies. while Sonic Crystal is made which can fix the sound at the frequency is wanted. In general, Sonic Crystal used is made of iron or aluminum. In this research used a resonator pipe made of PVC pipe with half-cylinder shape. The panel variations used are 1.5 ", 2", and 2.5" with pipe length 60 cm. Measurements were made at the semianechoic room of the Acoustic Physics laboratory, the FIA ITS Physics department. The method used in the test is based on the method written by C. Lagarrigue. From the measurements obtained the resonance frequency for 1.5 "pipe is 24 frequency point and the main bandgap is between 817,5 Hz - 819,5 Hz with maximum attenuation of -11,70 dB. Size 2 "is a 27 point frequency and the main bandgap between 800 Hz - 841.5 Hz with a maximum attenuation of -8.25 dB. The pipe size of 2.5 "is 41 frequency point and the main bandgap is between 546,5 Hz - 630 Hz with maximum attenuation -14,41 dB. From the measurement results it can be seen that the pipe size change resulted in the increasing number of resonating points and the main bandgap occurs at intermediate frequency between 500 Hz - 800 Hz.

Item Type: Thesis (Undergraduate)
Uncontrolled Keywords: akustik, frekuensi, panel, pipa, resonansi, resonator
Subjects: Q Science > QC Physics > QC221 Acoustics. Sound
Divisions: Faculty of Natural Science > Physics > 45201-(S1) Undergraduate Thesis
Depositing User: Andi Wardana
Date Deposited: 22 Jul 2021 23:20
Last Modified: 22 Jul 2021 23:20
URI: http://repository.its.ac.id/id/eprint/57817

Actions (login required)

View Item View Item