Pengaruh Sistem Proteksi Gas Accumulator terhadap Sistem Perpipaan (Studi Kasus di Unit Instalasi Pengolahan Air Minum (IPAM) Karang Pilang 1 PT PDAM Surya Sembada Surabaya

Jourdy Putri, Alda Vionetta (2018) Pengaruh Sistem Proteksi Gas Accumulator terhadap Sistem Perpipaan (Studi Kasus di Unit Instalasi Pengolahan Air Minum (IPAM) Karang Pilang 1 PT PDAM Surya Sembada Surabaya. Diploma thesis, Institut Teknologi Sepuluh Nopember.

[thumbnail of 10211500000072-Non_degree.pdf]
Preview
Text
10211500000072-Non_degree.pdf - Accepted Version

Download (5MB) | Preview

Abstract

Water hammer adalah fenomena terjadinya fluktuasi tekanan yang timbul akibat peningkatan dan penurunan kecepatan aliran dalam pipa secara tiba-tiba di daerah discharge pompa. Hal ini memiliki dampak negatif untuk sistem perpipaan. Penanganan yang cepat menjadi alasan utama untuk mengatasi water hammer, yaitu menggunakan proteksi water hammer. Penelitian ini mendiskusikan pengaruh salah satu sistem proteksi, yaitu gas accumulator pada sistem perpipaan di unit IPAM Karang Pilang 1 PT PDAM Surya Sembada Surabaya. Pada penelitian ini, pemodelan sistem perpipaan dilakukan dengan menggunakan perangkat lunak AFT Impulse 4.0. Sistem perpipaan yang disimulasikan merupakan sistem perpipaan dengan ada tidaknya pemasangan gas accumulator sebagai sistem proteksi. Hal ini untuk mengetahui dampak dari pemasangan gas accumulator. Hasil yang didapatkan pada simulasi berupa plot grafik dari fluktuasi tekanan yang terjadi pada sistem perpipaan. Dari adanya sistem proteksi, gas accumulator mampu meredam terjadinya lonjakan tekanan akibat water hammer dan mampu menstabilkan pipa lebih cepat supaya pipa terhindar dari kerusakan yang parah.
=================================================================================================
Water hammer phenomenon is a phenomenon of the occurrence of pressure fluctuations arising from increasing and decreasing the flow velocity in the piping that occur suddenly at discharge pump area. It has negative impact for piping system. Fast handling being main reason to overcoming water hammer phenomenon, which uses water hammer protection. This research is for discuss about the effect of one of protection system, is gas accumulator on piping system at unit IPAM Karang Pilang 1 PT PDAM Surya Sembada Surabaya. In this research, modeling piping system use software named AFT Impulse 4.0. Piping system which simulated is piping system with and without gas accumulalor as protection system. This research is for know the impact of gas accumulator. The results obtained in the simulation in the form of a plot graph of pressure fluctuations which occur in piping systems. From the existence of protection system, gas accumulator can reduce a bump pressure due to water hammer and can stabilize pipe faster, so the pipe can avoid the damage.

Item Type: Thesis (Diploma)
Uncontrolled Keywords: water hammer, AFT Impulse, gas accumulator
Subjects: T Technology > TJ Mechanical engineering and machinery > TJ935 Pipe--Fluid dynamics. Tubes--Fluid dynamics