Alat pemanas air adalah alat yang berfungsi untuk mengubah temperature suatu jenis fluida. Proses tersebut terjadi dengan memanfaatkan proses perpindahan kalor dari fluida temperature rendah menuju fluida temperature tinggi. Yang mana akan memberikan supply air panas untuk heat exchanger. Pada penelitian ini, difokuskan pada usaha untuk memaksimalkan pengendalian Heater agar air panas yang dihasilkan untuk supply air untuk heat exchanger. Secara umum prinsip kerjanya ialah ketika air yang ada pada tangki dengan suhu kamar atau 25°C maka heater akan menyala sehingga air pada tangki sesuai dengan set point yaitu 70°C, lalu tekanan pada tangki akan memberikan dorongan pada air untuk menuju ke heat exchanger. Cara yang digunakan untuk memanipulasi temperature adalah dengan mengatur arus yang diberikan pada heater agar sesuai dengan set pointnya. Metode control yang digunakan pada sistem ini adalah kontrol Proporsional (P) dimana diberikan nilai Kp sebesar 31. Hasil Pengujian didapatkan waktu untuk perubahan temperature hingga set point ialah 18 menit.
==========================================================================================================
Water heater is a tool that serves to change the temperature of a type of fluid. The process occurs by utilizing the process of heat transfer from low temperature fluid to high temperature fluid. Which one will provide hot water supply for heat exchanger. In this study, it focused on efforts to maximize Heater control for hot water generated for the supply of water for heat exchangers. Generally the working principle is when the water is in the tank with room temperature or 25 ° C then the heater will light so that the water in the tank according to the set point is 70 ° C, then the pressure on the tank will give a boost on the water to get to the heat exchanger. The way used to manipulate the temperature is to adjust the current given on the heater to fit the set point. Control method used in this system is Proportional control (P) where given the value of Kp of 31. Testing results obtained time for temperature changes to set point is 18 minutes.

Item Type: Thesis (Diploma)
Additional Information: RSIn 681.753 Rau r-1 3100018076693
Uncontrolled Keywords: Heater, Temperature, Arus, Heater, Temperature, current