Pengurangan Insiden Energi Arc Flash Dengan Menggunakan Metode Zone Selective Interlocking Pada PT. Petrochina

Erlangga, Muhammad Shahrizal (2015) Pengurangan Insiden Energi Arc Flash Dengan Menggunakan Metode Zone Selective Interlocking Pada PT. Petrochina. Undergraduate thesis, Institut Technology Sepuluh Nopember.

[img]
Preview
Text
2212106011-Undergraduate Thesis.pdf - Published Version

Download (1MB) | Preview

Abstract

Arc Flash yang terjadi pada sistem kelistrikan menimbulkan kerugian yang sangat besar. Insiden energi yang dilepaskan dapat merusak peralatan dan terutama dapat membahayakan pekerja yang bekerja di lingkungan tersebut. Perlu sistem pengaman yang mampu mengatasi gangguan tersebut. Koordinasi pengaman yang selektif tentu akan mempertimbangkan jarak waktu antar pengaman untuk menjaga kontinuitas serta stabilitas aliran daya ke lokasi yang tidak mengalami gangguan. Permasalahan yang timbul adalah hal tersebut mengakibatkan pengamanan dari Arc Flash belum efektif dalam mengurangi bahaya Arc Flash. Sesuai dengan standar koordinasi proteksi, pengaman yang semakin jauh dari beban setting waktunya akan diset relatif lebih lama untuk menjaga selektifitas. Hal tersebut mengakibatkan insiden energi Arc Flash akan besar. Zone Selective Interlocking sebagai sebuah metode yang bekerja berdasarkan komunikasi antar pengaman menjadi solusi yang sesuai dengan permasalahan tersebut. ZSI dapat mengurangi insiden energi Arc Flash tanpa mengorbankan selektifitas dari koordinasi pengaman sehingga kontinuitas daya tetap terjaga. Penerapan teknik ZSI ini akan coba diterapkan pada sistem tegangan rendah 0.48 kV CPA Petrochina mengingat pentingnya perusahaan tersebut mengamankan peralatan serta pekerjanya dari insiden energi Arc Flash yang besar. ==================================================================================================== Arc flash that occurs on the electrical system causing huge losses. Incident energy released can damage equipment and endanger workers employed in these environments. We need a protection system that is able to cope with the disorder. Selective coordination of protection which will consider the intervals between the protective device to maintain the continuity and stability of the power flow is not susceptible to interference. The problem that arises is that system is not effective in reducing the impact of arc flash hazards. In accordance with the standards, the low voltage protective device away from the load will set a relatively long disruptions to maintain selectivity, but its impact is arc flash incident energy will be higher. Zone Selective Interlocking as a method based on the communication between protective device give solutions that fit the problem. ZSI can reduce Arc Flash incident energy without sacrificing selectivity of protection coordination so that the continuity of power is still safe. So we try apply this ZSI to the low voltage system 0,48 kV CPA Petrochina to give secure for workers and the equipment from high Arc Flash incident energy.

Item Type: Thesis (Undergraduate)
Additional Information: RSE 621.319 1 Erl p
Uncontrolled Keywords: Arc Flash, Busur Api, Gangguan, Zone Selective Interlocking,
Subjects: T Technology > T Technology (General) > T174.5 Technology--Risk assessment.
Divisions: Faculty of Industrial Technology > Electrical Engineering > (S1) Undergraduate Theses
Depositing User: Mr. Tondo Indra Nyata
Date Deposited: 10 Aug 2018 07:21
Last Modified: 10 Aug 2018 07:21
URI: http://repository.its.ac.id/id/eprint/59278

Actions (login required)

View Item View Item