Deteksi Lokasi Gangguan Pada Jaringan Distribusi Dengan Percabagangan Menggunakan Metode Gelombang Berjalan

Amania, Radhyana Alamah (2015) Deteksi Lokasi Gangguan Pada Jaringan Distribusi Dengan Percabagangan Menggunakan Metode Gelombang Berjalan. Undergraduate thesis, Institut Technology Sepuluh Nopember.

[img]
Preview
Text
2212106082-Undergraduate Thesis.pdf - Published Version

Download (2MB) | Preview

Abstract

Pada beberapa kasus di sistem distribusi, gangguan sering kali terjadi dan lokasi gangguan sulit untuk dideteksi. Dibutuhkan waktu yang cukup lama untuk menemukan lokasi titik gangguan tersebut. Pada tugas akhir ini, dilakukan perhitungan lokasi titik gangguan menggunakan gelombang berjalan untuk mempercepat proses perbaikan setelah gangguan. Pada saluran distribusi, besarnya arus gangguan dapat mengindikasikan lokasi terjadinya gangguan, hal ini dapat dianalisa melalui perambatan sinyal arus balik saat terjadi gangguan. Gelombang akan merambat menyebar ke kedua arah ujung saluran dengan kecepatan mendekati kecepatan cahaya. Ketika terjadi gangguan inilah tegangan dan arus titik gangguan tiba-tiba menurun sampai ke nilai rendah. Perubahan secara tiba-tiba ini yang menghasilkan dorongan energi elektromagnetik frekuensi tinggi. Perhitungan estimasi lokasi gangguan secara umum dilakukan dengan menghitung selisih waktu tunda antara gelombang arus datang (maju) yaitu puncak pertama saat terjadi gangguan dan gelombang arus refleksinya yaitu puncak gelombang berikutnya yang di deteksi sebagai arus mundur nya. Dari penelitian ini diperoleh eror terbesar 8.75 %. ====================================================================================================== In some cases in the distribution system, disturbances often occur and fault location is difficult to detect. It takes a long time to find the location of the fault point. In this thesis, the location calculation using the interruption point wave to accelerate the repair process after disturbance. By using traveling wave method, used analysis of high frequency voltages and currents in the distribution system. Waves will propagate spread to both ends of the channel direction at speeds approaching the speed of light. When this interference voltage and current interruption point suddenly falls to a low value. Sudden change is that generate high-frequency electromagnetic energy boost. Calculation of fault location estimation is generally done by calculating the difference in time delay between the current wave coming (forward) ie when the first peak current wave interference and reflection are the next wave crest in detection as its backward flow.

Item Type: Thesis (Undergraduate)
Additional Information: RSE 621.319 Ama d
Uncontrolled Keywords: Gangguan Hubung singkat, Gelombang Berjalan, Sistem Distribusi
Subjects: T Technology > TK Electrical engineering. Electronics Nuclear engineering > TK201 Electric Power Transmission
Divisions: Faculty of Electrical Technology > Electrical Engineering > (S1) Undergraduate Theses
Depositing User: Mr. Tondo Indra Nyata
Date Deposited: 16 Aug 2018 03:33
Last Modified: 16 Aug 2018 03:33
URI: http://repository.its.ac.id/id/eprint/59387