Studi Perbandingan Perhitungan Volume Menggunakan Data Total Station Dengan Dan Tanpa Prisma

Rahayu, Leny Puji (2015) Studi Perbandingan Perhitungan Volume Menggunakan Data Total Station Dengan Dan Tanpa Prisma. Undergraduate thesis, Institut Technology Sepuluh Nopember.

[thumbnail of 3510100021-Undergraduate Thesis.pdf]
Preview
Text
3510100021-Undergraduate Thesis.pdf - Published Version

Download (3MB) | Preview

Abstract

Pengukuran topografi adalah suatu pekerjaan penentuan tempat kedudukan baik secara horisontal maupun vertikal pada segala sesuatu yang terdapat pada permukaan areal tanah yang diukur. Pengukuran topografi dilakukan di bidang pekerjaan penggalian dan penimbunan tanah yang erat kaitannya dengan perhitungan volume. Volume yang dimaksud disini adalah apabila ingin menggali atau menimbun tanah pada suatu tempat (cut and fill) atau untuk menghitung material (bahan) galian yang sifatnya padat. Perkembangan teknologi membuat pekerjaan pengukuran topografi menjadi lebih mudah, karena ditunjang dengan alat-alat yang semakin canggih. Alat Takheometer Elektronik (ATE) atau yang dikenal dengan sebutan total station adalah alat hasil kom-binasi teodolit elektronik dengan alat Pengukur Jarak Elektronik (PJE) dan kolektor elektronik. Berdasarkan spesifikasi beberapa merk total station dapat membidik tanpa prisma dengan jarak se-jauh 300 meter. Apabila hasil yang didapat antara pengukuran menggunakan total station dan prisma dengan total station tanpa prisma tidak memiliki selisih yang signifikan, tentu adanya total station tipe ini sangat efisien dan memudahkan dalam proses pen-gukuran.
vi
Dalam menunjukkan ada tidaknya selisih yang signifikan dari hasil pengukuran yang diperoleh dari pengukuran menggunakan total station dan prisma dengan total station tanpa menggunakan prisma, penelitian ini mencoba melakukan per-bandingan standar deviasi dari selisih elevasi hasil pengukuran Total Station Foif prisma dan nonprisma–Waterpass dan Total Station Sokkia prisma dan nonprisma–Waterpass (pada area yang relatif datar dan bergelombang) serta perbandingan volume cut and fill yang diukur menggunakan total station prismadan total station nonprisma dengan referensi elevasi yang diukur menggunakan Waterpass.
Hasil penelitian ini menunjukkan bahwa pengukuran Standar deviasi selisih elevasi di area pakuwon yang memiliki nilai tertinggi adalah alat Total Station Foif prisma- Waterpass sebesar 0,029 m, dan untuk yang terendah adalah Total Station Sokkia nonprisma-Waterpass sebesar 0,023 m. Standar deviasi selisih elevasi di area penelitian gunung anyar untuk yang tertinggi adalah Total Station Foif nonprisma- Waterpass sebsar 0,367 m, dan yang terendah Total Station Sokkia nonprisma- Wa-terpass sebesar 0,264 m. Setelah dilakukan uji normalitas, nilai standar deviasi untuk pakuwon tetap, karena point yang dielimi-nasi haya dua. Untuk area gunung anyar, semua data pengukuran diterima. Selisih perhitungan volume cut and fill di area pakuwon yang tertinggi adalah adalah Total Station Sokkia prisma yaitu sebesar 204,131 m3 , sedangkan selisih terkecil diperoleh dari hasil pengukuran menggunakan Total Station Sokkia nonprisma yaitu sebesar 64,056 m3. Untuk lokasi gununganyar selisih vol-ume paling besar adalah dengan alat Total Station Foif prisma- Waterpass adalah sebesar -223,444 m3, dan yang paling kecil adalah alat Total Station Sokkia prisma- Waterpass adalah sebe-sar 4,453 m3.
=======================================================================================================
Topography measurement is a work of determining the horizontal position or the verical position on everything con-tained in the surface of the land area measured. Topography measurements made in the field of excavation and landfill which is closely related to the volume calculation. The volume which meant here is if you want to dig or hoard land at a place (cut and fill) or to calculate the material (material) that are excavated sol-id. The development of technology made the job of topography measurement is easier, because it is supported by means of in-creasingly sophisticated. Electronic Takheometer tool (ATE) or known as total station is the result of a combination of electronic theodolite tool with Electronic Distance Measuring tool (pje) and electronic collector. Based on the specifications of several brands,there is total station can taking aim without prism with a distance of 300 meters. If the measurement results obtained using the total station with a prism and a total station without prism does not have significant differences, their typesof total station are very efficient and simplify the measurement process. In show-ing whether there is a significant difference from the measure-ment results obtained from measurements using a total station
viii
and a prism with a total station without using a prism, this re-search tries to do a comparison of the standard deviation of the difference in elevation measurement results Foif reflector and reflectorless TS-WP and TS Sokkia reflector and reflectorless-WP (the area is relatively flat and corrugated) and the ratio of cut and fill volumes were measured using a Total Station reflector and reflectorless Total Station with reference elevation measured using the water pass.
The results of this study indicate that the measurement standard deviation difference in elevation in the area Pakuwon which has the highest value is a tool-Prism Total Station Foif WP at 0,029 m, and the lowest was for Total Station Sokkia Nonprisma-WP of 0,023 m. The standard deviation of the differ-ence in elevation on gununganyar research area for the highest is the Total Station Foif Nonprisma-WP is 0,367 m, and the lowest Total Station Sokkia Nonprisma-WP is 0,264 m. After the normal-ity test, the standard deviation value for Pakuwon is fixed, be-cause points are eliminated haya two. For gununganyar area, all measurement data is received. Difference calculation of cut and fill volumes in the area is the highest pakuwon is Sokkia reflector of Total Station is equal to 204,131 m3, while the smallest differ-ence is obtained from the measurement results using Sokkia reflectorless of Total Station is equal to 64,056 m3. For the loca-tion of gununganyar greatest volume difference is the tool Foif Prisma Total Station-Waterpass is at -223,444 m3, and the small-est is the tool Sokkia Prisma Total Station-Waterpass is equal to 4,453 m3.

Item Type: Thesis (Undergraduate)
Additional Information: RSG 624.151 36 Rah s
Uncontrolled Keywords: Pengukuran Topografi, Cut and Fill, Total Sta-tion
Subjects: T Technology > TA Engineering (General). Civil engineering (General)
Divisions: Faculty of Civil Engineering and Planning > Geomatics Engineering > 29202-(S1) Undergraduate Thesis
Depositing User: Mr. Tondo Indra Nyata
Date Deposited: 10 Sep 2018 02:27
Last Modified: 10 Sep 2018 02:27
URI: http://repository.its.ac.id/id/eprint/59605

Actions (login required)