Abstract

Heat Recovery Steam Generator (HRSG) adalah salah satu komponen dari pembangkit listrik dengan prinsip kerja combined cycle yang digunakan pada Pusat Listrik Tenaga Gas dan Uap (PLTGU). HRSG menggunakan dua turbin yaitu turbin gas dan turbin uap. Permasalahan yang sering terjadi adalah adanya kegagalan pada tubetube HRSG. Hal ini dapat menyebabkan pada penurunan efisiensi dari HRSG. Untuk mengetahui kegagalan yang terjadi, maka dilakukan analisis dengan mendeskripsikan model kegagalan pada HRSG menggunakan metode Fuzzy Fault Tree Analysis (FFTA). FFTA merupakan salah satu metode analisis keandalan yang digunakan untuk memodelkan kegagalan dari suatu peralatan. Hasil dari analisis FFTA ini berupa nilai keandalan dan interval keandalan dari masing-masing peralatan yang mampu menangani ketidakpastian yang sebelumnya sulit diselesaikan dengan teori probabilistik konvensional. Berdasarkan analisis FFTA yang telah dilakukan terdapat 3 peralatan yang mempunyai nilai keandalan sangat rendah yaitu, LP Economizer 1.2 mempunyai nilai keandalan 0,45974 dengan interval keandalan 0,405718 dan 0,51377. HP Economizer 1.2 mempunyai nilai keandalan 0,45974 dengan interval keandalan 0,405718 dan 0,51377. Dan LP Boiler Feed Pump 3A mempunyai nilai keandalan 0,517013 dengan interval keandalan 0,468714 dan 0,521843. ==================================================================================== Heat Recovery Steam Generator (HRSG) is one component of the power plant with the principle on the combined cycle used in steam and gas power plants. HRSG use two turbines they are gas turbines and steam turbine. The problem that often occurs is that there is a failure in the HRSG tubes. This can lead to a decrease in the efficiency of the HRSG. To know that failure occurs, then analyzed the failure of a model describing the HRSG using Fuzzy Fault Tree Analysis (FFTA). FFTA is one of the methods of analysis used to model the reliability of an equipment failure. The results of the analysis is value FFTA interval reliability of each piece of equipment that is capable of dealing with imprecision and uncertainty which is difficult to be characterized by the traditional probabilistic theory. Based on FFTA analysis has been done, there are 3 equipments that has a very low value reliability. The reliability LP economizer 1.2 is 0.45974 it has interval between 0.405718 and 0.51377, The reliability HP economizer 1.2 is 0.45974 it has interval between 0.405718 and 0.51377, And The reliability Boiler Feed Pump 3A LP is of 0.517013 it has interval between 0.468714 and 0.521843.

Item Type: Thesis (Undergraduate)
Additional Information: RSE 621.402 Ant a
Uncontrolled Keywords: FTA; FFTA; HRSG; Keandalan; Pemrograman PHP; MySQL
Subjects: T Technology > TK Electrical engineering. Electronics Nuclear engineering > TK1001 Production of electric energy or power
Divisions: Faculty of Industrial Technology > Electrical Engineering > (S1) Undergraduate Theses
Depositing User: - Taufiq Rahmanu
Date Deposited: 09 Oct 2018 03:01
Last Modified: 09 Oct 2018 03:01
URI: http://repository.its.ac.id/id/eprint/59798

Actions (login required)

View Item View Item