Perancangan active fault tplerant control pada separate line calciner (SLC) preheater pabrik Tuban II di PT. Semen Indonesia (Persero) Tbk dengan kesalahan pada sensor temperatur

Kurniawati, Shilvia (2015) Perancangan active fault tplerant control pada separate line calciner (SLC) preheater pabrik Tuban II di PT. Semen Indonesia (Persero) Tbk dengan kesalahan pada sensor temperatur. Undergraduate thesis, Institut Teknologi Sepuluh Nopember.

[img] Text
2411100041-Undergraduate_Theses-ok.pdf
Restricted to Repository staff only

Download (3MB) | Request a copy

Abstract

Sensor temperatur dari separate line calciner (SLC) preheater Pabrik Tuban II di PT. Semen Indonesia (Persero) Tbk sering mengalami perbaikan akibat kesalahan pembacaan. Pada Tugas Akhir ini dilakukan perancangan sistem kontrol yaitu active fault tolerant control (AFTC) yang mampu bekerja ketika terdapat suatu kesalahan yang terjadi pada sensor dan dapat mempertahankan performansinya. Langkah awal yang dilakukan adalah pemodelan dari proses yang terjadi pada SLC preheater. Langkah kedua adalah merancang observer dengan pendekatan modified PD descriptor observer. Langkah terakhir adalah merekonfigurasi sistem kontrol. Hasil simulasi menunjukkan bahwa dari uji kesalahan bias, sensitivitas, dan noise diperoleh kestabilan temperatur pada setpoint 890 oC dengan maximum overshoot sebesar 5,6%, error steady state sebesar 0%, dan settling time 50 detik. ============================================================================================ Temperature sensor of the separate line calciner (SLC) preheater Tuban II Cement Plant in PT. Semen Indonesia (Persero) Tbk often have repaired because of an error reading. On this final project, designing control systems namely active fault tolerant control (AFTC) who are able to work when there is a fault that occurs in the sensor and can maintain the performance. The first step undertaken was the modeling of processes that occur at the SLC preheater. The second step is to design observer with a modified PD descriptor observer approach. The final step is the reconfiguration control system. Simulation results show that the test of bias, noise, and sensitivity, temperature stability obtained at set point 890 °C with maximum overshoot of 5,6%, steady state error of 0%, and settling time of 50 seconds.

Item Type: Thesis (Undergraduate)
Additional Information: RSF 629.831 2 Kur p
Uncontrolled Keywords: active fault tolerant controll modified PD descriptor observerl; SLC preheater; Control theory; Automatic control; design process control
Subjects: T Technology > TJ Mechanical engineering and machinery > TJ213 Automatic control.
T Technology > TN Mining engineering. Metallurgy
Divisions: Faculty of Industrial Technology > Physics Engineering > (S1) Undergraduate Theses
Depositing User: - Taufiq Rahmanu
Date Deposited: 16 Oct 2018 02:50
Last Modified: 16 Oct 2018 02:50
URI: http://repository.its.ac.id/id/eprint/59869