Analisis Perpindahan Panas Pada Kondensor Unit IV PLTU Di PT. PJB UP Gresik

Fauziyyah, Atika Marlida (2015) Analisis Perpindahan Panas Pada Kondensor Unit IV PLTU Di PT. PJB UP Gresik. Diploma thesis, Institut Technology Sepuluh Nopember.

[img]
Preview
Text
2112030079-Non Degree.pdf - Published Version

Download (3MB) | Preview

Abstract

PT. PJB UP Gresik adalah salah satu perusahaan jasa dibidang produksi tenaga listrik yang berada di kawasan industri Gresik, untuk kemudian disalurkan ke sistem interkoneksi Jawa- Bali. Jumlah Daya listrik yang dihasilkan oleh perusahaan ini sebesar 2.260 Mega Watt (MW) yang terdiri dari dua unit pembangkit listrik tenaga gas, empat unit pembangkit listrik tenaga uap, dan tiga blok unit pembangkit listrik tenaga gas dan uap. PT. PJB UP Gresik sendiri mempunyai peralatan-peralatan pendukung beroperasinya turbin uap yang berputar dan berhubungan dengan generator. Diantara pendukungnya adalah kondensor. Kondensor adalah salah satu jenis pesawat penukar kalor yang berfungsi mengkondensasikan uap bekas dari turbin, yaitu air laut. Jenis kondensor yang digunakan pada PLTU Unit IV PT. PJB UP Gresik adalah surface condenser. PLTU Unit IV PT. PJB UP Gresik memiliki kapasitas 200 MW dengan tekanan vakum pada kondensor sebesar 695 mmHg. Pada tugas akhir ini, mencakup proses perhitungan dilakukan dengan menggunakan analisa perpindahan panas dengan metode Log Mean Temperature Different (LMTD) dan NTU-Effectiveness di kondensor Unit IV PLTU . Dalam perhitungan, memvariasikan beberapa hal yang berpengaruh pada efektifitas kondensor ini. Analisa perpindahan panas dan effectiveness digunakan untuk mengetahui kerja kondensor unit IV pada tanggal 9 Juni 2014 sampai tanggal 11 Juni 2014. Diambil sampling data pada saat performance test kondensor pada beberapa hari yang disebutkan dan dengan data aktual v beban, kevakuman kondensor, suhu (temperatur) masuk dan keluar steam, suhu (temperatur) masuk dan keluar air laut yang saling mendekati; kemudian direrata. Hasil yang didapat dari tugas akhir ini adalah nilai laju perpindahan panas dan effectiveness (ε) kondensor unit IV dari tanggal 9 Juni 2014 sampai 11 Juni 2014. Pada kondensor unit IV, ditanggal 9 Juni 2014 sampai tanggal 10 Juni 2014 diperoleh laju perpindahan panas sebesar 153.6001264 MW. Ditanggal 10 Juni 2014 sampai tanggal 11 Juni 2014 diperoleh laju perpindahan panas sebesar 131.9188202 MW. Sedangkan effectiveness (ε), ditanggal 9 Juni 2014 sampai 10 Juni 2014 diperoleh 0.99571 % dan ditanggal 10 Juni 2014 sampai 11 Juni 2014 didapat 0.99661 %. Hal ini menunjukkan bahwa keadaan kondensor cukup baik, dikarenakan steam dapat menuju kondensor, sehingga laju perpindahan panas dan effektifitas kondensor mampu mengkondensasi steam menjadi cair. ======================================================================================================= PT. PJB UP Gresik is one service company in the production of electric power at industrial area of Gresik, for distributed to the Java-Bali with interconnection system. Electrical power amount generated by these companies amounted to 2.260 Mega Watt (MW) consisting of two gas-fired power generation units, four units of the steam power plant, and three blocks of power plants and steam gas. PT. PJB UP Gresik alone has the equipment supporting the operation of the steam turbine that rotates and is associated with the generator. Among its supporter are condensers. The condenser is one of the best types of heat exchanger that functions of the former steam condensing turbine, is seawater. Condenser type used in the power plant Unit IV PT. PJB UP Gresik is a surface condenser. Power Plant Unit IV PT. PJB UP Gresik has a capacity of 200 MW with the condenser vacuum pressure of 695 mmHg. In this thesis, includes the calculation process is done by using a heat transfer analysis method Different Log Mean Temperature (LMTD) and NTU-Effectiveness in Unit IV power plant condenser. In the calculation, varying some of the things that influence the effectiveness of this condenser and heat transfer analysis used to determine the effectiveness of work condenser unit IV on June 9, 2014 until June 11, 2014. Taken sampling data during the performance test condenser on some days indicated and the actual data load, the vacuum condenser, the temperature of incoming and outgoing temperature steam, the temperature of incoming and outgoing temperature of the sea water approach each other; then average it. The results of this thesis is the value of heat transfer rate and effectiveness (ε) condenser unit IV of the date of June 9, 2014 until June 11, 2014. At condenser unit IV, the date of June 9, 2014 until the date of June 10, 2014 obtained the heat transfer rate of 153.6001264 MW. The date of June 10, 2014 until the date of June 11, 2014 obtained the heat transfer rate of 131.9188202 MW. While the effectiveness (ε), the date June 9, 2014 until June 10, 2014 was obtained 0.99571% and the date of June 10, 2014 until June 11, 2014 0.99661% obtained. This shows that the state of the condenser is good enough, because the steam can head condenser, so the heat transfer rate and effectiveness steam condenser capable of condensing into liquid.

Item Type: Thesis (Diploma)
Additional Information: RSM 621.402 2 Fau a
Uncontrolled Keywords: Kondensor, Laju Perpindahan Panas, Effektifitas
Subjects: T Technology > TJ Mechanical engineering and machinery > TJ263 Heat exchangers
Divisions: Faculty of Industrial Technology > Mechanical Engineering > (D3) Diploma
Depositing User: Mr. Tondo Indra Nyata
Date Deposited: 19 Dec 2018 03:23
Last Modified: 19 Dec 2018 03:23
URI: http://repository.its.ac.id/id/eprint/60100