Perekam Citra Ultrasound pada Logic Scan CEXT-1Z

Priambodo, Joko (2015) Perekam Citra Ultrasound pada Logic Scan CEXT-1Z. Undergraduate thesis, Institut Technology Sepuluh Nopember.

[thumbnail of 2211100054-Undergraduate Thesis.pdf]
Preview
Text
2211100054-Undergraduate Thesis.pdf - Published Version

Download (2MB) | Preview

Abstract

Penanganan untuk penyumbatan pembuluh darah dilakukan
dengan metode kateterisasi. Namun metode ini tidak aman dikarenakan
metode ini masih menggunakan xray untuk menemukan kepala kateter.
X-ray dapat mengakibatkan kanker apabila dilakukan secara terus
menerus. Alternatif yang dapat dilakukan adalah menggunakan
ultrasonography 2D yang terkait erat dengan posisi dan orientasi probe
USG pada saat pengambilan citra. Dengan berbasis sinyal ultrasonik,
peralatan ini dapat menghasilkan citra bagian dalam tubuh.Untuk tujuan
rekonstruksi volume/membangun objek 3D dari potongan citra 2D, tugas
akhir ini menangkap potongan citra ultrasonography dan melakukan
konfigurasi pada mesin ultrasonography agar dapat menangkap dengan
tipikel yang sesuai dengan karakteristik obyek penelitian. Konfigurasi dan
citra yang ditangkap oleh ultrasonography, dapat digunakan pada
penelitian terkait pemodelan objek 3D berbasis probe ultrasonography
sebagai citra acuan 2D objek. Dari hasil penelitian didapat bahwa
parameter yang paling berpengaruh untuk menangkap citra ultrasound
adalah frekuensi dan gain.Untuk frekuensi minimum yang dapat
digunakan untuk menangkap citra phantom adalah 8 MHz. Sedangkan
rekomendasi konfigurasi untuk mendapatkan obyek yang diinginkan
adalah 8-10MHZ dengan Gain 20-40%. Dikarenakan hanya obyek
penelitian saja yang tertangkap dengan kualitas noise paling sedikit.
Dengan metode ini dapat disimpulkan untuk menangkap obyek yang lain
diperlukan konfigurasi yang tepat untuk menghilangkan noise.
====================================================================================================
Handling for blocked of blood vessel it can done with
catheterization method. But this method is not safe because this method
is still used xray to find the head of the catheter. X-rays can lead to cancer
if done continuously. Alternatives that can be done by use 2D
ultrasonography, are closely associated with the position and orientation
of the ultrasound probe at the time of image acquisition. With ultrasonic
signal based, this equipment can produce images inside body.For
destination volume reconstruction / building 3D objects from 2D image
slice, this final project captures the image pieces ultrasonography and
configured the ultrasonography machine in order to capture the
characteristic which are in accordance with the characteristics
.Configuration of objects and images captured by ultrasonography can
be used in research related to modeling 3D objects, based probe 2D
ultrasonography as the reference image objects. The result is that the
most influential parameters to capture the ultrasound image is gain and
frequency.For minimum frequency and minimum gain that can be used to
capture the image of the phantom is 8MHz. And configuration
recommendations to get the desired object is 8-10MHz frequency and
gain 20-40% . Because only objects of research are caught with the least
noise quality. With this method it can be concluded to capture another
object required the right configuration to eliminate noise.

Item Type: Thesis (Undergraduate)
Additional Information: RSE 616.075 43 Jok
Uncontrolled Keywords: 3D Ultrasound, USG, Konfigurasi, Citra
Subjects: T Technology > TA Engineering (General). Civil engineering (General) > TA1637 Image processing--Digital techniques
Divisions: Faculty of Industrial Technology > Electrical Engineering > 20201-(S1) Undergraduate Thesis
Depositing User: Mr. Tondo Indra Nyata
Date Deposited: 02 Jan 2019 02:54
Last Modified: 02 Jan 2019 02:54
URI: http://repository.its.ac.id/id/eprint/60124

Actions (login required)

View Item View Item