Proteksi Adaptif Untuk Koordinasi Optimal Digital Rele Arus Lebih Menggunakan Modified Firefly Algorithm Pada Sistem Distribusi Radial Dengan Pembangkit Tersebar

Faizin, Alfa Kusnal (2015) Proteksi Adaptif Untuk Koordinasi Optimal Digital Rele Arus Lebih Menggunakan Modified Firefly Algorithm Pada Sistem Distribusi Radial Dengan Pembangkit Tersebar. Undergraduate thesis, Institut Technology Sepuluh Nopember.

[img] Text
2211100133-Undergraduate Thesis.pdf - Published Version

Download (3MB)

Abstract

Rele arus lebih adalah peralatan proteksi yang penting dalam sistem tenaga. Adanya pembangkit tersebar menimbulkan beberapa tantangan untuk melindungi sistem distribusi. Untuk mengurangi kerugian akibat arus beban lebih maupun arus gangguan hubung singkat dan menghindari kesalahan opearasi rele backup, karena itu koordinasi rele arus lebih dalam sistem proteksi menjadi perhatian utama para insinyur proteksi dan peneliti. Tugas akhir ini menyajikan koordinasi optimal OCR pada sistem distribusi radial dengan DG. Koordinasi optimal OCR didasarkan pada pemilihan nilai time dial setting (TDS) dan arus pickup (Ipickup) untuk mendapatkan waktu operasi rele minimal. Modified firefly algorithm (MFA) diusulkan untuk mencari koordinasi optimal OCR. Metode MFA digunakan pada sistem dengan tiga pembangkit yang berbeda dengan berbagai kondisi sistem. Metode MFA dibandingkan dengan metode firefly algorithm (FA) asli. Hasil penelitian menunjukkan bahwa metode yang diusulkan secara signifikan dapat meningkatkan hasil dari FA asli dan dapat mengurangi waktu operasi dari koordinasi OCR. =================================================================================================== Overcurrent relays (OCRs) is an important devices in the power system. In the presence of distribution generation (DG), cause several challenges to protection of distribution system. To reduce effect of overload and overcurrent and avoid mal-operation of the backup relays, therefor OCR coordination in protection system get a major concern of the protection engineer and researcher. This paper presents an optimal OCR coordination in power distribution system under the presence of DG. An optimal OCR coordination is based on the selection of time dial setting (TDS) and pickup current inorder to obtain minimum operating time for the relays. A modified firefly algorithm (MFA) is proposed to finds the optimal OCR coordination. The proposed method is applied to three different case studies with DG in several of system condition. The proposed method is compared with the original firefly algorithm. The results show that the proposed method can significantly improve the result of the original firefly algorithm and reduce operating time of the OCR coordination.

Item Type: Thesis (Undergraduate)
Additional Information: RSE 621.317 Fai p
Uncontrolled Keywords: hubung singkat, modified firefly algorithm, time dial setting (TDS), arus pickup
Subjects: T Technology > TK Electrical engineering. Electronics Nuclear engineering > TK2861 Electric relays
Divisions: Faculty of Industrial Technology > Electrical Engineering > (S1) Undergraduate Theses
Depositing User: Mr. Tondo Indra Nyata
Date Deposited: 22 Jan 2019 02:18
Last Modified: 22 Jan 2019 02:18
URI: http://repository.its.ac.id/id/eprint/60252