Studi Perbandingan Sistem HVAC antara Sistem Central dan Sistem Split pada Cold Storage Terapung Menggunakan Gorlov Helical Turbine

Bimantoro, Bagas (2019) Studi Perbandingan Sistem HVAC antara Sistem Central dan Sistem Split pada Cold Storage Terapung Menggunakan Gorlov Helical Turbine. Undergraduate thesis, Institut Teknologi Sepuluh Nopember.

[thumbnail of 04211541000012-Bagas Bimantoro_Thesis.pdf] Text
04211541000012-Bagas Bimantoro_Thesis.pdf - Published Version
Restricted to Repository staff only

Download (10MB) | Request a copy

Abstract

Potensi sumber daya ikan laut Indonesia mencapai 65 juta ton per tahun yang tersebar di perairan Zona Terirorial dan Zona Ekonomi Eksklusif Indonesia. Indonesia memiliki sumber daya perikanan paling banyak di Laut Arafura dengan total 855 ribu ton (KEPMEN No.24 tahun 2014). Berdasarkan penelitian yang telah dilakukan, nelayan di Indonesia membutuhkan setidaknya 1125 unit cold storage, tetapi hanya 201 unit yang tersedia saat ini. Penyebaran cold storage juga tidak merata. Dari 201 unit yang tersedia, 60% berada di Pulau Jawa dan hanya 0,5% tersedia di Papua dan sekitarnya yang sebenarnya memiliki potensi perikanan terbesar di Indonesia (Kementerian Kelautan dan Perikanan, 2016). Inilah penyebab hasil perikanan yang kurang maksimal. Dari permasalahan yang ada, penulis berinovasi untuk memodifikasi KM Mina Jaya Niaga 11 yang telah diteliti sebelumnya menjadi Alternative Powered Floating Cold Storage yang memanfaatkan potensi energi arus laut menggunakan Gorlov Helical Turbine sebagai sumber daya cold storage di Laut Arafura. Dalam penelitian ini, penulis akan membandingkan sistem terbaik antara Central Cold Storage System dan Split Cold Storage System. Hasil dari penelitian ini adalah Central System lebih baik untuk diaplikasikan pada KM Mina Jaya Niaga 11 dibandingkan dengan Split System. Central System membutuhkan daya 480 kW untuk beroperasi dimana Split System membutuhkan daya 540 kW. Central System juga memiliki keuntungan secara ekonomis dengan selisish investasi untuk pembangunan system sebesar Rp. 293.953.000 jika dibandingkan dengan Split System. Keuntungan lainnya adalah maintenance yang mudah dan sistemperpipaan yang lebih pendek dengan selisih panjang pipa 354.1 m dibandingkan Split System. Desain terbaik untuk Gorlov Helical Turbine yang digunakan pada KM Mina Jaya Niaga 11 menggunakan material ABS Molded dengan tinggi 3 m dan diameter 3,5 m. Turbin ini dapat bekerja optimal dengan kecepatan arus laut mulai dari 2,5 m/s dimana arus minimum di laut Arafura adalah 4 m/s.
=============== Indonesia's sea fish resources potential reaches 65 million tons per year spread over the waters of the Terirorial Zone and the Exclusive Economic Zone of Indonesia. Indonesia has the most fishery resources in the Arafura Sea with a total of 855 thousand tons (Decree of Ministry of Marine Affairs and Fisheries No.24 of 2014). Based on research that has been done, fishermen in Indonesia need at least 1125 units of cold storage, but only 201 units are available to date. The spread of cold storage is also uneven. Of the 201 units available, 60% are on the island of Java and only 0.5% are available in Papua and surrounding areas that in fact have the greatest fishery potential in Indonesia (Ministry of Marine Affairs and Fisheries, 2016). This is the cause of fishery results that are less than the maximum. From the existing problems, author are innovating to modify KM Mina Jaya Niaga 11 that has beed researched before into Alternative Powered Floating Cold Storage that utilizes the potential of ocean current energy using Gorlov Helical Turbine as a source of cold storage power in Arafura Sea. In this study, authors will compare the best system between Central Cold Storage System and Split Cold Storage System. The result of this study are Central System is better to be installed in KM Mina Jaya Niaga 11 comparing with Split System.. Central System need power 480 kW to operate while Split System need power 540 kW. Central System also has an economic advantages with investment cost difference Rp. 293,953,000 comparing with Split System. Another advantage is easy to maintenance and the piping system is shorter with 354.1 m of difference comparing with Split System. The best design of Gorlov Helical Turbine for KM Mina Jaya Niaga 11 using ABS Molded material with a 3 meter high and 3.5 meter diameter. This turbine is able to work optimally with flows starting at 2.5 m / s where the lowest current on the Arafuru Sea is 4 m / s.

Item Type: Thesis (Undergraduate)
Uncontrolled Keywords: Cold Storage, Gorlov Helical Turbine, Renewable Energy, Refrigeration System.
Subjects: V Naval Science > V Naval Science (General)
V Naval Science > VM431 Fishing boats
Divisions: Faculty of Marine Technology (MARTECH) > Marine Engineering > 36202-(S1) Undergraduate Thesis
Depositing User: Bagas Bimantoro
Date Deposited: 04 Feb 2019 01:47
Last Modified: 04 Feb 2019 01:47
URI: http://repository.its.ac.id/id/eprint/61799