Optimasi rekonfigurasi jaring menggunakan load curtailment untuk mengisolasi gangguan dalam distribution automation system pada sistem microgrid

Asri, Andarini (2015) Optimasi rekonfigurasi jaring menggunakan load curtailment untuk mengisolasi gangguan dalam distribution automation system pada sistem microgrid. Masters thesis, Institut Teknologi Sepuluh Nopember.

[img] Text
2213201006-master.pdf

Download (2MB)

Abstract

Microgrid merupakan jaring listrik dengan injeksi sumber renewable energy yang menggunakan teknologi informasi dan komunikasi untuk bertindak berdasarkan informasi, seperti informasi mengenai supply dan konsumen. Microgrid memberikan tantangan baru, berupa otomatisasi peralatan pada sistem distribusi yang disebut Distribution Automation System untuk jaring listrik konvensional. Semakin meningkatnya pemakaian energi listrik maka semakin berpotensi terjadinya gangguan hubung singkat. Setelah mengetahui lokasi dan jenis gangguan hubung singkat, selanjutnya informasi ini akan diolah ke pusat kendali untuk dilakukan proses penanganan gangguan. Dalam penelitian ini, jenis penanganan gangguan yang akan digunakan adalah dengan melakukan rekonfigurasi jaring. Teknik rekonfigurasi jaring yang dilakukan adalah Load Curtailment. Dari hasil analisis yang dilakukan, Load Curtailment dapat meminimalkan kerugian daya total pada jaring distribusi. Yaitu kerugian daya total terbesar pada sistem IEEE 33 Bus menurun dari 8,941362 KW menjadi 7,162925 KW dan untuk sistem Karangasem menurun dari 0,063284 KW menjadi 0,036021 KW. =================================================================================================== Microgrid is an electricital network with the injection of renewable energy sources that use information and communication technologies, such as information on the supply and consumers. Microgrid provide new challenges, such as automation equipment in the distribution system called the Distribution Automation System for conventional electricity network. The increasing consumption of electrical energy, the more potential occurrence of short circuit. After knowing the location and type of short circuit, this information will be processed to the control center to do the process of handling disturbances. In this study, the type of treatment interruption that will be used is to do a network reconfiguration. Reconfiguration techniques are Load Curtailment. From the results of the analysis carried out, Load Curtailment can minimize the total power losses in the distribution system. The largest total power losses in the IEEE 33 bus system decreased from 7.162925 KW to 8.941362 KW and for Karangasem system be decreased from 0.063284 KW to 0.036021 KW.

Item Type: Thesis (Masters)
Additional Information: RTE 621.319 Asr o
Uncontrolled Keywords: distribution automation system, load curtailment, microgrid, rekonfigurasi ===================================================================================================== distribution automation system, load curtailment, microgrid, reconfiguration
Subjects: T Technology > TK Electrical engineering. Electronics Nuclear engineering > TK201 Electric Power Transmission
T Technology > TK Electrical engineering. Electronics Nuclear engineering > TK1322.6 Electric power-plants
Divisions: Faculty of Electrical Technology > Electrical Engineering > (S2) Master Theses