Azmi, Gema Fajri (2015) Studi Perilaku Balok Cfts Menggunakan U-Link Dengan Balok Cfts Tanpa U-Link. Undergraduate thesis, Institut Teknologi Sepuluh Nopember.
Preview |
Text
3112106024-presentation.pdf - Presentation Download (1MB) | Preview |
Preview |
Text
3112106024-paper.pdf - Published Version Download (1MB) | Preview |
Preview |
Text
3112106024-Undergraduate_Theses.pdf - Published Version Download (3MB) | Preview |
Abstract
Menggunakan sistem baru Shear Connector berbentuk
U-link pada balok Concrete Filled Steel Tube atau biasa
disebut CFTs, untuk menggabungkan tabung baja dengan inti
beton dari sisi tekanan balok mengakibatkan pengekangan
besar pada inti beton. Hal ini dapat dibenarkan dengan
mempertimbangkan bahwa tabung baja memberikan
pengekangan pada beton, dan stabilitas yang diberikan oleh
beton pada tekuk baja.
Secara umum Tugas Akhir ini akan melakukan validasi
hasil eksperimen dari Madiha, Moayyad, dan Abdelqader,
2013 tentang perbandingan 2 jenis penampang CFTs balok
dengan bentuk persegi panjang, yang satu menggunakan shear
connector berbentuk U-link dan satunya lagi tanpa shear
connector terhadap kapasitas CFTs dalam menerima beban
lentur. Akan tetapi dalam tugas akhir ada sedikit modifikasi
penampang.
Pada hasil analisa menggunakan program bantu berbasis
Computer Aided Engineering (CAE) didapat nilai tegangan
(S33) untuk penampang CFTs tanpa U-Link bentang 8 meter
sebesar 263,546 MPa, bentang 10 meter sebesar 272,892 MPa,
dan bentang 12 meter sebesar 276,862 MPa. Besarnya
tegangan (S33) untuk penampang CFTs dengan U-Link
bentang 8 meter sebesar 221,146 MPa, bentang 10 meter
iv
sebesar 237,528 MPa, dan bentang 12 meter sebesar 250,759
MPa. Besarnya regangan (ε33) untuk penampang CFTs tanpa
U-Link bentang 8 meter sebesar 0,007394, bentang 10 meter
sebesar 0,031376, dan bentang 12 meter sebesar 0,035374.
Sedangkan besarnya nilai regangan (ε33) untuk penampang
CFTs dengan U-Link bentang 8 meter sebesar 0,004101,
bentang 10 meter sebesar 0,021862, dan bentang 12 meter
sebesar 0,031435.
Berdasarkan nilai tegangan dan regangan yang terjadi,
penampang CFTs tanpa U-Link lebih bagus dari pada
penampang CFTs dengan U-Link. Jika dilihat dari nilai
regangan maka semakin panjang bentang balok maka semakin
daktail balok tersebut. ========== Using the new system Shear Connector shaped U-link
on beam Concrete Filled Steel Tube or so-called CFTs, to
incorporate the steel tube with concrete core by the pressure
side of the beam resulting of great restraints on the concrete
core. This can be justified by considering that the steel tube
provides restraint concrete curbs, and stability provided by the
concrete on steel buckling.
In general, this final project will validate the
experimental results of Madiha, Moayyad, and Abdelqader,
2013 about comparison of two types of beam CFTs crosssectional
with a rectangular shape, which one uses U-link
shaped shear connector and the other without shear connector
on the capacity of CFTs in receiving a bending load. But in
this final project there is a slight cross-section modification.
From the analysis result of using the assist program
based Computer Aided Engineering (CAE) are obtained values
of the tension (S33) for CFTs cross-section without U-Link 8
meter length equal to 263,546 Mpa, 10 meter length equal to
272,892 Mpa, and 12 meter length equal to 276,862 MPa. The
values of the tension (S33) for CFTs cross-section with U-Link
are 8 meter length equal to 221,146 MPa, 10 meter length
equal to 237,528 MPa, and 12 meter length equal to 250,759
ii
MPa. The values of the strain (ε33) for CFTs cross-section
without U-Link are 8 meter length equal to 0,007394, 10 meter
length equal to 0,031376, and 12 meter length equal to
0,035374. The values of the strain (ε33) for CFTs cross-section
with U-Link are 8 meter length equal to 0,004101, 10 meter
length equal to 0,021862, and 12 meter length equal to
0,031435.
Based on the values of the tension and the strain
happened, CFTs cross-section without U-Link is better than
CFTs cross-section with U-Link. From the result of the strain
values can be concluded that the longer beam length, the more
ductile the beam.
Item Type: | Thesis (Undergraduate) |
---|---|
Additional Information: | RSS 624.171 Azm s |
Uncontrolled Keywords: | CFTs, U-Link, pengekangan, daktail, balok baja, CFTs, U-Link, restraint, ductile, steel beam |
Subjects: | T Technology > TA Engineering (General). Civil engineering (General) > TA645 Structural analysis (Engineering) T Technology > TA Engineering (General). Civil engineering (General) > TA658 Structural design T Technology > TA Engineering (General). Civil engineering (General) > TA660.C6 Columns |
Divisions: | Faculty of Civil Engineering and Planning > Civil Engineering > 22201-(S1) Undergraduate Thesis |
Depositing User: | - Davi Wah |
Date Deposited: | 15 Apr 2019 08:09 |
Last Modified: | 15 Apr 2019 08:09 |
URI: | http://repository.its.ac.id/id/eprint/62763 |
Actions (login required)
View Item |