Studi Perilaku Balok Cfts Menggunakan U-Link Dengan Balok Cfts Tanpa U-Link

Azmi, Gema Fajri (2015) Studi Perilaku Balok Cfts Menggunakan U-Link Dengan Balok Cfts Tanpa U-Link. Undergraduate thesis, Institut Teknologi Sepuluh Nopember.

[img]
Preview
Text
3112106024-presentation.pdf - Presentation

Download (1MB) | Preview
[img]
Preview
Text
3112106024-paper.pdf - Published Version

Download (1MB) | Preview
[img]
Preview
Text
3112106024-Undergraduate_Theses.pdf - Published Version

Download (3MB) | Preview

Abstract

Menggunakan sistem baru Shear Connector berbentuk U-link pada balok Concrete Filled Steel Tube atau biasa disebut CFTs, untuk menggabungkan tabung baja dengan inti beton dari sisi tekanan balok mengakibatkan pengekangan besar pada inti beton. Hal ini dapat dibenarkan dengan mempertimbangkan bahwa tabung baja memberikan pengekangan pada beton, dan stabilitas yang diberikan oleh beton pada tekuk baja. Secara umum Tugas Akhir ini akan melakukan validasi hasil eksperimen dari Madiha, Moayyad, dan Abdelqader, 2013 tentang perbandingan 2 jenis penampang CFTs balok dengan bentuk persegi panjang, yang satu menggunakan shear connector berbentuk U-link dan satunya lagi tanpa shear connector terhadap kapasitas CFTs dalam menerima beban lentur. Akan tetapi dalam tugas akhir ada sedikit modifikasi penampang. Pada hasil analisa menggunakan program bantu berbasis Computer Aided Engineering (CAE) didapat nilai tegangan (S33) untuk penampang CFTs tanpa U-Link bentang 8 meter sebesar 263,546 MPa, bentang 10 meter sebesar 272,892 MPa, dan bentang 12 meter sebesar 276,862 MPa. Besarnya tegangan (S33) untuk penampang CFTs dengan U-Link bentang 8 meter sebesar 221,146 MPa, bentang 10 meter iv sebesar 237,528 MPa, dan bentang 12 meter sebesar 250,759 MPa. Besarnya regangan (ε33) untuk penampang CFTs tanpa U-Link bentang 8 meter sebesar 0,007394, bentang 10 meter sebesar 0,031376, dan bentang 12 meter sebesar 0,035374. Sedangkan besarnya nilai regangan (ε33) untuk penampang CFTs dengan U-Link bentang 8 meter sebesar 0,004101, bentang 10 meter sebesar 0,021862, dan bentang 12 meter sebesar 0,031435. Berdasarkan nilai tegangan dan regangan yang terjadi, penampang CFTs tanpa U-Link lebih bagus dari pada penampang CFTs dengan U-Link. Jika dilihat dari nilai regangan maka semakin panjang bentang balok maka semakin daktail balok tersebut. ========== Using the new system Shear Connector shaped U-link on beam Concrete Filled Steel Tube or so-called CFTs, to incorporate the steel tube with concrete core by the pressure side of the beam resulting of great restraints on the concrete core. This can be justified by considering that the steel tube provides restraint concrete curbs, and stability provided by the concrete on steel buckling. In general, this final project will validate the experimental results of Madiha, Moayyad, and Abdelqader, 2013 about comparison of two types of beam CFTs crosssectional with a rectangular shape, which one uses U-link shaped shear connector and the other without shear connector on the capacity of CFTs in receiving a bending load. But in this final project there is a slight cross-section modification. From the analysis result of using the assist program based Computer Aided Engineering (CAE) are obtained values of the tension (S33) for CFTs cross-section without U-Link 8 meter length equal to 263,546 Mpa, 10 meter length equal to 272,892 Mpa, and 12 meter length equal to 276,862 MPa. The values of the tension (S33) for CFTs cross-section with U-Link are 8 meter length equal to 221,146 MPa, 10 meter length equal to 237,528 MPa, and 12 meter length equal to 250,759 ii MPa. The values of the strain (ε33) for CFTs cross-section without U-Link are 8 meter length equal to 0,007394, 10 meter length equal to 0,031376, and 12 meter length equal to 0,035374. The values of the strain (ε33) for CFTs cross-section with U-Link are 8 meter length equal to 0,004101, 10 meter length equal to 0,021862, and 12 meter length equal to 0,031435. Based on the values of the tension and the strain happened, CFTs cross-section without U-Link is better than CFTs cross-section with U-Link. From the result of the strain values can be concluded that the longer beam length, the more ductile the beam.

Item Type: Thesis (Undergraduate)
Additional Information: RSS 624.171 Azm s
Uncontrolled Keywords: CFTs, U-Link, pengekangan, daktail, balok baja, CFTs, U-Link, restraint, ductile, steel beam
Subjects: T Technology > TA Engineering (General). Civil engineering (General) > TA645 Structural analysis (Engineering)
T Technology > TA Engineering (General). Civil engineering (General) > TA658 Structural design
T Technology > TA Engineering (General). Civil engineering (General) > TA660.C6 Columns
Divisions: Faculty of Civil Engineering and Planning > Civil Engineering > 22201-(S1) Undergraduate Thesis
Depositing User: - Davi Wah
Date Deposited: 15 Apr 2019 08:09
Last Modified: 15 Apr 2019 08:09
URI: http://repository.its.ac.id/id/eprint/62763