Kalibrasi flow meter dalam aliran fluida pada sistem manifold

Asy`Ari, Muhammad Khamim (2014) Kalibrasi flow meter dalam aliran fluida pada sistem manifold. Undergraduate thesis, Institut Teknologi Sepuluh Nopember.

[thumbnail of 2411031018-Undergraduate_Theses.pdf]
Preview
Text
2411031018-Undergraduate_Theses.pdf - Published Version

Download (5MB) | Preview

Abstract

Telah dirancang alat eksperimen kalibrasi flow meter pada sistem manifold yang berfungsi untuk mengetahui nilai ketidakpastian, serta untuk mengetahui pengaruh sistem manifold terhadap kalibrasi flow meter. Cara kerja sistem alat eksperimen ini yaitu pada kondisi awal ditentukan besar bukaan manual valve. Kemudian ditekan push button sehingga solenoid valve terbuka dan mengalirkan air ke talang air. Selanjutnya air mengalir melalui flow meter. Air keluaran flow meter akan ditampung dalam gelas ukur, dihitung nilai volumenya, dan digunakan sebagai pembacaan standar. Sedangkan perubahan nilai dari flow meter digunakan sebagai pembacaan alat. Dari hasil kalibrasi flow meter didapatkan nilai ketidakpastian diperluas terkecil untuk valve dengan bukaan ¼ pada flow meter B sebesar 0,0111 L, untuk valve dengan bukaan ½ pada flow meter B sebesar 0,0978 L, untuk valve dengan bukaan ¾ pada flow meter D sebesar 0,0741 L, dan untuk valve dengan bukaan 1 pada flow meter D sebesar 0,1172 L. ========== Device experiment calibration of flowmeter in flowrate manifold system has been designed which used to determine the values of the uncertainty and to determine the effect manifold system of calibration flowmeter. Work principle of this experimental device is in the first conditions has been determined the large of valve opening. Then the push button is pressed so the solenoid valve is open and drain the water in to water storage. Then the water drain through the flowmeter. Water flowmeter output will be accomodated in a glass measuremen. Whereas the change value of flowmeter uses as device reading. The result of this flowmeter calibration the values obtained that the minimum expanded uncertainty of valve in ¼ opening in flowmeter B is 0,0111 L, the expanded uncertainty of valve in ½ opening in flowmeter B is 0,0978 L, the expanded uncertainty of valve in ¾ opening in flowmeter B is 0,0741 L, the expanded uncertainty of valve in 1 opening in flowmeter B is 0,1172 L.

Item Type: Thesis (Undergraduate)
Additional Information: RSF 620.106 4 Asy k
Uncontrolled Keywords: flow meter, calibration, expanded uncertainty, manifold system, flow meter, kalibrasi, ketidakpastian diperluas, sistem manifold
Subjects: Q Science > QC Physics > QC271.8.C3 Calibration
Divisions: Faculty of Industrial Technology > Physics Engineering > 30201-(S1) Undergraduate Thesis
Depositing User: - Davi Wah
Date Deposited: 14 May 2019 06:18
Last Modified: 14 May 2019 06:18
URI: http://repository.its.ac.id/id/eprint/63024

Actions (login required)

View Item View Item