Wijaya, Kevin Christian (2015) Rancang Bangun Aplikasi Android Untuk Mengukur Konsentrasi Leukosit Esterase Dan Keberadaan Nitrit Dalam Urin Pada Hasil Tes Dipstick Untuk Studi Kasus Infeksi Saluran Kemih. Undergraduate thesis, Institut Technology Sepuluh Nopember.
Preview |
Text
5111100107-Undergraduate Thesis.pdf - Published Version Download (2MB) | Preview |
Abstract
Dilema utama dalam dunia medis adalah dalam
pemberian obat-obatan untuk pasien asimtomatik yang terdeteksi
bakteri pada urinnya . Penggunaan obat antibiotik dalam
beberapa kasus dapat menyembuhkan penyakit infeksi saluran
kemih yang terdeteksi dini. Namun, karena bakteri akan
membentuk sistem imun terhadap obat, penting untuk tidak
melakukan pemberian obat antibiotik pada pasien asimtomatik
kecuali terdapat bukti kuat bahwa pasien terdeteksi penyakit
infeksi saluran kemih. Namun mengingat instrumen yang sudah
ada berharga relatif mahal dan hanya dapat digunakan oleh
tenaga ahli, penggunaan kamera smartphone dapat digunakan
dalam pembacaan warna reagen dipstick urinalysis sebagai salah
satu instrumen untuk pendeteksian bakteri pada urin sejak dini.
Untuk mencapai tujuan tersebut diperlukan sebuah
sistem pengolahan warna reagen pada dipstick yang dapat
dipasang pada smartphone, khususnya untuk reagen leukosit
esterase dan nitrit yang merupakan indikator untuk menentukan
kemunculan bakteri pada urin. Salah satu permasalahan dalam
sistem tersebut adalah menentukan metode dan ruang warna
yang sesuai, sehingga nilai warna yang didapat dapat
merepresentasikan warna yang dapat diolah menjadi hasil yang
viii
akurat dan dapat dipercaya. Sistem yang dapat memperoleh nilai
yang dapat merepresentasikan warna yang ada dalam citra strip
dipstick dikembangkan dalam ruang warna CIELab dengan
menerapkan metode berbasis Stepwise Linear Interpolation untuk
mengukur tingkat konsentrasi leukosit esterase dan nitrit.
Hasil uji coba menunjukkan bahwa metode Stepwise
Linear Interpolation dapat digunakan untuk mengidentifikasikan
level reagen leukosit dan nitrit. Namun, kalibrasi hitam putih
belum dapat diterapkan sebagai representasi kalibrasi
pencahayaan karena memiliki tingkat akurasi yang rendah
sehingga penggunaan data master masih belum dapat dilakukan.
Selain itu dalam beberapa kasus reagen leukosit membutuhkan
penelitian lebih lanjut untuk menghasilkan metode yang sesuai
dalam mengidentifikasikan warna yang tidak sesuai dengan level
warna.
=========================================================================================================
A common dilemma in clinical medicine is whether to treat
asymptomatic patients who present with bacteria in their urine.
There are few scenarios in which antibiotic treatment of
asymptomatic bacteriuria has been shown to improve patient
outcomes. Because of increasing antimicrobial resistance, it is
important not to treat patients with asymptomatic bacteriuria
unless there is evidence of potential benefit. For this purpose, a
urinalysis dipstick reagent color acquisition is important, mainly
for leukocytes esterase and nitrites reagent which can be an
indicator for early detection of Urinary Tract Infection (UTI).
Smartphone camera can be used to help people interpreting
reagent colors, rather than using expensive instrument that can
only be used by professionals.
To accomplish that goal a system that can interpret reagent
colors and can be installed on smartphone is needed. One of the
main issue in developing this system is what color space and
method are used, so the values extracted can represent color in
the dipstick for further process to obtain reliable result . Reagent
detection and acquisition system is developed CIELab color
space using a Stepwise Linear Interpolation based method to
measure the level of leukocytes esterase and nitrites reagent in
urine.
x
Experimental result proves that Stepwise Linear
Interpolation can determine reagent level of nitrite and
leukocytes. But, black white calibration can’t representing light
calibration so data master can’t be applied. And in some
situation, a further experiment needed for produce reliable
method that can determine reagent level which are not in color
chart.
Item Type: | Thesis (Undergraduate) |
---|---|
Additional Information: | RSlf 006.42 Wij r |
Uncontrolled Keywords: | Leukosit Esterase, Nitrit, Infeksi Saluran Kemih, Reagen, Disptick Urinalysis, Stepwise Linear Interpolation, Kamera, Smartphone, Otomatis |
Subjects: | Q Science > QA Mathematics > QA76.774.A53 Android T Technology > TA Engineering (General). Civil engineering (General) > TA1637 Image processing--Digital techniques |
Divisions: | Faculty of Information Technology > Informatics Engineering > 55201-(S1) Undergraduate Thesis |
Depositing User: | Mr. Tondo Indra Nyata |
Date Deposited: | 27 Jun 2019 03:41 |
Last Modified: | 27 Jun 2019 03:41 |
URI: | http://repository.its.ac.id/id/eprint/63309 |
Actions (login required)
View Item |