Penentuan Nilai Optimal Super Kapasitor Untuk Memperbaiki Kestabilan Transien Berbasis Metode Losing Synchronism

Riambodo, Arief (2019) Penentuan Nilai Optimal Super Kapasitor Untuk Memperbaiki Kestabilan Transien Berbasis Metode Losing Synchronism. Other thesis, Institut Teknologi Sepuluh Nopember.

[thumbnail of 07111540000034-Undergraduate_Theses.pdf]
Preview
Text
07111540000034-Undergraduate_Theses.pdf

Download (1MB) | Preview

Abstract

Gangguan arus hubung singkat tiga fasa merupakan salah satu gangguan transien yang harus segera diisolir untuk mencegah terjadinya kehilangan sinkronisasi pada pembangkit dan agar sistem tetap stabil. Critical clearing time (CCT) merupakan waktu maksimal pemutusan yang diperbolehkan untuk mengisolasi gangguan agar sistem tetap stabil. Pemasangan Sistem penyimpanan energi Super Kapasitor pada sistem adalah salah satu cara untuk meningkatkan nilai CCT pada sistem. Super Kapasitor adalah salah satu penyimpan energi yang mampu mensuplai dan menyimpan tenaga listrik dalam jumlah besar dengan cepat. Super Kapasitor dapat meningkatkan nilai CCT dengan cara meredam osilasi yang ditimbulkan oleh gangguan 3 fasa. Dengan nilai CCT yang lebih besar, maka waktu operasi dari sistem proteksi lebih panjang . Hasilnya, sistem akan tetap stabil setelah gangguan diisolasi dan hal ini dapat meningkatkan kestabilan transien dari sistem. Dengan penentuan nilai Super Kapasitor yang optimal pada sistem maka akan didapatkan nilai CCT yang lebih besar dari waktu operasi sistem proteksi yang ada. Sehingga pada penelitian ini akan dilakukan optimasi nilai Super Kapasitor untuk memperbaiki kestabilan transien sistem tenaga listrik menggunakan metode Critical Trajectory berbasis Losing Synchronism.
===============================================================================================================================
Three phase fault is one of a transient phenomenon that must be isolate immediately to prevent losing synchron of generator in power plant, so that the system remain stable. Critical clearing time is maximum time allowed to isolate the system fault so that the system remain stable. Super capacitor energy storage installation to the system is one way to improve CCT value. Super capacitor is one of energy storage that be able to supply and store large amounts of electricity power quickly. Super Capacitor can improve CCT value by muffle oscillation of 3 phase fault. With higher CCT value, then time operation of protection system can be longer. The result is the system remain stable after fault removed and it can be improve transient stability in power system. Within an optimal sizing of super capacitor capacities for the system, then the value of CCT that obtained is higher than protection time operation. So that in this final project will be carried out an optimal sizing of super capacitor for improving transient stability with critical trajectory based on losing synchronism method.

Item Type: Thesis (Other)
Additional Information: RSE 621.315 Ria p-1 2019
Uncontrolled Keywords: Kestabilan transien, Critical clearing time, Super kapasitor, critical trajectory, Losing synchronism
Subjects: T Technology > TK Electrical engineering. Electronics Nuclear engineering > TK1010 Electric power system stability. Electric filters, Passive.
Divisions: Faculty of Electrical Technology > Electrical Engineering > 20201-(S1) Undergraduate Thesis
Depositing User: Arief Riambodo
Date Deposited: 08 Mar 2023 01:12
Last Modified: 08 Mar 2023 01:12
URI: http://repository.its.ac.id/id/eprint/63782