Analisa Water Hammer pada Motor Driven Feedwater Boiler Pump (MBFP) di PLTU Tanjung Awar-awar, Tuban

Prakoso, Ayub Hari (2019) Analisa Water Hammer pada Motor Driven Feedwater Boiler Pump (MBFP) di PLTU Tanjung Awar-awar, Tuban. Other thesis, Institut Teknologi Sepuluh Nopember.

[thumbnail of 02111140000077-Undergraduate_Theses.pdf] Text
02111140000077-Undergraduate_Theses.pdf
Restricted to Repository staff only

Download (3MB) | Request a copy

Abstract

Untuk memindahkan sebuah fluida dari suatu tempat menuju tempat lain, diperlukan sebuah saluran dari sistem perpipaan. Sistem perpipaan merupakan salah satu hal yang memegang peranan penting dalam dunia teknik karena dibutuhkan dalam berbagai keperluan seperti mentransportasikan fluida dari sebuah reservoir ke reservoir yang lain, memindahkan fluida dari suatu subsistem menuju subsistem yang lain, dan lain-lain. Dalam sistem perpipaan terdapat pipa, pompa, kompresor, turbin, fittings dan sebagainya serta dibutuhkan perencanaan instalasi yang baik dan pemilihan komponen yang tepat. Terdapat berbagai fenomena yang terjadi dikarenakan sifat-sifat dari fluida itu sendiri. Salah satu fenomena dalam sistem perpipaan yang terjadi adalah kavitasi dan water hammer. Dalam sebagian besar keadaan kavitasi adalah hal yang tidak diinginkan dan dihindari karena dapat merusak bagian-bagian dalam sebuah sistem perpipaan dan juga dibuat sistem proteksi untuk melindungi pipa dari pengaruh water hammer agar tidak mengalami kerusakan. Pada Simulasi kali ini pemodelan sistem perpipaan dilakukan dengan menggunakan software AFT Impulse 5.0. Sistem yang disimulasikan merupakan sistem perpipaan yang ada pada PLTU Tanjung Awar-awar. Simulasi kali ini bertujuan untuk mengkaji tentang kavitasi pada sistem perpipaan, pengaruh tekanan didalam pipa terhadap nilai ketebalan pipa, fenomena water hammer beserta pengaruhnya terhadap sistem perpipaan, dan pengaruh dari sistem proteksi pressure relief valve dan rupture-disk relief valve terhadap fenomena water hammer. Variasi yang digunakan adalah Nominal Pipe Size sebesar 12”, 14”, 16” dan suhu kerja fluida sebesar 150oC, 170oC, 180oC. Kajian kavitasi dilakukan dengan menggunakan analisa steady dimana pompa bekerja secara konstan sedangkan kajian water hammer dan sistem proteksi dilakukan dengan menggunakan analisa transient dimana putaran pompa menurun dari 100% menjadi 0% dalam waktu satu detik. Berdasarkan hasil simulasi terjadi kavitasi pada analisa steady dengan variasi 12”, 14”, 16” dengan suhu kerja fluida 170oC dan 180oC. Pada variasi 12”, 14”, 16” dengan suhu kerja fluida harus dilakukan perubahan ketebalan pipa agarmampu menahan tekanan yang bekerja di dalam pipa. Kajian water hammer pada analisa transient menunjukan bahwa tekanan meningkat dengan nilai tekanan tertinggi terdapat pada variasi 12” dan suhu kerja fluida 150oC sebesar 2976,5 psia. Pada analisa transient juga terlihat bahwa pressure relief valve mampu mengurangi nilai tekanan tertinggi pada saat terjadi water hammer namun tidak mampu meredam fluktuasi tekanan sedangkan rupture-disk relief valve mampu mengurangi nilai tekanan tertinggi saat terjadi water hammer dan mampu meredam fluktuasi tekanan.
===================================================================================================================================
Moving a fluid from one place to another place needs a pipeline from a piping system. Piping System is one of many things that holds important role in engineering world because it is needed in many occasion like transporting fluids. In piping systems there is pipe, pump, compressor, turbine, fittings, etc. and also a good instalation plan with the right selection of components. there is a lot of phenomenon that happened because of the traits of the fluid. one of those phenomenons are cavitation and water hammer. in most cases, cavitation is not desired or avoided because it can damage the piping system and protection system is also made to protect the piping system from water hammer. In this simulation, piping system modeling is being done using the AFT Impulse 5.0 software. the simulated system was an existing piping system in PLTU Tanjung Awar-awar. this simulation was made with the purpose of studying the effect of fluid temperature and pressure to cavitation, water hammer, and pipe thickness. this simulation is also studying the effect of relief valve in protecting pipes from water hammer. the variation being used is the diameter of the pipe which is 12 inch, 14 inch, 16 inch and the temperature of the fluid which is 150 celcius, 170 celcius, 180 celcius. this study used the steady state analysis where the pump work constantly and the protection system study is being done using the transient analysis where the pump suddenly stop rotating in 2 seconds. From the simulation, cavitation happened in steady analysis in 12, 14, and 16 inch pipe with 170 and 180 celcius fluid. There is a need in changing the thickness of the pipe in 12, 14, 16 inch pipe to be able to withstand the pressure inside the pipe. in the transient analysis shows that 12 inch pipe shows the highest pressure with 2976,5 psia. transient analysis also shows that pressure relief valve can reduce the peak pressure that happened when water hammer occured but can not reduce the fluctuation of the fluid inside the pipe while rupture-disk relief valve can reduce the fluid fluctuation while causing a significant lowest pressure.

Item Type: Thesis (Other)
Uncontrolled Keywords: Kavitasi, Relief valve, Water Hammer
Subjects: T Technology > TA Engineering (General). Civil engineering (General) > TA357 Computational fluid dynamics. Fluid Mechanics
Divisions: Faculty of Industrial Technology > Mechanical Engineering > 21201-(S1) Undergraduate Thesis