Studi Numerik Pada Pengujian Momen Bending Dua dan Empat Titik Terhadap Fleksibilitas Balloon-Expandable Stent

Anggara, Yusuf Tri (2019) Studi Numerik Pada Pengujian Momen Bending Dua dan Empat Titik Terhadap Fleksibilitas Balloon-Expandable Stent. Other thesis, Institut Teknologi Sepuluh Nopember.

[thumbnail of 02111540000126-Undergraduate_Theses.pdf] Text
02111540000126-Undergraduate_Theses.pdf
Restricted to Repository staff only

Download (2MB) | Request a copy

Abstract

Stenting merupakan usaha untuk membuka aliran darah yang menyempit serta menghalangi terjadinya proses penyempitan kembali (restenosis) oleh plak menggunakan stent. Stent sendiri adalah tabung berongga yang dibentuk dari kawat dengan profil tertentu. Mengingat vitalnya fungsi stent, perlu dilakukan evaluasi keamanan dan performa stent yang ada sebelum digunakan pada penanganan penyakit kardiovaskuler. Evaluasi keamanan dan performa yang perlu dilakukan antara lain fleksibilitas, trackability, dan conformability. Nilai fleksibilitas stent didapatkan dari satu per nilai kekakuannya. Pada saat stent dihantarkan menuju posisi stenosis, stent yang melekat pada balon harus mamiliki fleksibilitas agar dapat mengatasi belokan pembuluh darah tanpa terjadi rusak berupa patah atau lainnya. Dilakukan pengujian numerik pada stent dalam kondisi tidak mengembang menggunakan metode elemen hingga dengan tiga desain stent yang berbeda, yaitu stent palmaz, sinusoidal dan spiral. Kemudian ketiga stent tersebut diuji menggunakan tiga variasi panjang, yaitu panjang 25mm dan 16mm. Variasi jenis stent digunakan untuk mengetahui perbandingan fleksibilitas dari ketiga jenis balloon-expandable stent berdasar pengaruh profil sambungan (link) dan sel stent. Sedangkan variasi panjang stent digunakan untuk mengetahui apakah fleksibilitas pada stent dengan panjang yang berbeda sesuai dengan teori. Metode pengujian flexibility yang dilakukan adalah bending test dengan momen seragam pada dua titik dan empat titik. Pengujian dilakukan tanpa memperhatikan efek plak, balon dan pembuluh darah. Hasil yang diperoleh dari simulasi ini antara lain adalah nilai fleksibilitas masing-masing stent dan perbandingannya. Hasil analisis menunjukkan fleksibilitas pada balloonexpandable stent pada setiap variasi panjang dan dengan metode momen dua titik maupun empat titik jenis spiral lebih fleksibel dibandingkan sinusoidal dan palmaz dengan nilai fleksibilitas stent spiral, stent sinusoidal, dan stent palmaz yaitu 0.06 N.mm2, 0.002 N.mm2, dan 0.0006 N.mm2 pada kondisi elastis. Nilai fleksibilitas balloon-expandable stent pada setiap variasi panjang bernilai sama dengan nilai eror tertentu
=====================================================================================================================================
Stenting is a process to reopen blood vessel that blocked by plague and avoid the process of re blocking in it (restenosis) by other plagues using a tool named stent. Stent itself is hollowed tube that made form wire in certain profile. Considering the vitality of stent, performances and its safety need to be evaluated before it is used for cardiovascular treatment. Performances that important to be evaluated are flexibility, trackability, and conformability. As known, flexibility itself equals to inverse of stiffness. When a stent is delivered to stenosis position, stent has to bend as flexible as it can so it will form a curve suited to vessel stiffness without any damage. Numerical study with finite element method used as a prediction to evaluate the flexibility of stent in unexpanded condition. Spiral, sinusoidal, and palmaz stent are the basic type of stent that are evaluated to know the effect of different profile in cell and strut between stents. Three of those evaluated in two terms of length, 25mm and 16mm, to know the effect of different length in flexibility. Loading method applied for stents are two point and four-point moment bending. Test applied with the effect of plagues, balloon, and blood vessel contact are neglected. As the result, flexibility test on balloon expandable stent in every length variation with two point and four point moment bending shows that spiral type is more flexible than sinusoidal type, and sinusoidal type is more flexible than palmaz type within elastic flexibility value as 0.06 N.mm2, 0.002, and 0.0006. Flexibility value for every variations of length in a kind of balloon expandable stent are same with certain error.

Item Type: Thesis (Other)
Uncontrolled Keywords: balloon-expandable stent, palmaz, sinusoidal, spiral, flexibility
Subjects: R Medicine > RA Public aspects of medicine > RA0421 Public health. Hygiene. Preventive Medicine
T Technology > T Technology (General) > T57.62 Simulation
T Technology > TA Engineering (General). Civil engineering (General) > TA174 Computer-aided design.
T Technology > TA Engineering (General). Civil engineering (General) > TA347 Finite Element Method
Divisions: Faculty of Industrial Technology > Mechanical Engineering > 21201-(S1) Undergraduate Thesis