Modifikasi Perencanaan Gedung Fakultas Farmasi Universitas Airlangga Kampus C Menggunakan Balok Hexagonal Castellated dengan Sistem Pengaku Steel Plate Shear Wall (SPSW)

Dewana, Dovan Alfano (2019) Modifikasi Perencanaan Gedung Fakultas Farmasi Universitas Airlangga Kampus C Menggunakan Balok Hexagonal Castellated dengan Sistem Pengaku Steel Plate Shear Wall (SPSW). Other thesis, Institut Teknologi Sepuluh Nopember.

[thumbnail of 03111540000032_Undergraduate_Theses.pdf]
Preview
Text
03111540000032_Undergraduate_Theses.pdf

Download (15MB) | Preview

Abstract

Surabaya sebagai kota terbesar kedua di Indonesia, mengalami perkembangan yang pesat, baik dari segi fisik maupun non fisik. Dengan luas wilayah 326,36 km2 (BPS, 2018). Maka akan terjadi kerugian sangat besar yang tidak hanya pada segi material namun juga segi korban jiwa bila tidak dilakukannya pencegahan dan antisipasi gempa bumi. Gedung Fakultas Farmasi Universitas AIirlangga Kampus C yang kemudian disebut dengan Gedung Fakultas Farmasi, sebelumnya dibangun dengan material beton bertulang dengan sistem Struktur Rangka Pemikul Momen Khusus (SRPMK) yang terdiri dari 14 lantai. Gedung ini difungsikan sebagai sarana pendidikan dengan status pemakaian yang padat. Antisipasi terhadap gempa sangat diperlukan dalam kontruksi gedung ini.
Pada perencanan tugas akhir ini Gedung Fakultas Farmasi dimodifikasi dari struktur beton bertulang menjadi baja dengan menggunakan balok Hexagonal Castellated dengan sistem pengaku Steel Plate Shear Wall (SPSW). Penggunaan balok Hexagonal Castellated diharapkan mampu memenuhi kebutuhan akan bentang ruangan yang lebar dengan profiil yang lebih kecil. Stell Plate Shear Wall (SPSW) merpakan salah satu sistem penahan beban lateral yag terdiri dari pelat baja vertical padat yang menghubugkan balok dan kolom disekitarnya dan terpasana sepanjang ketinggian struktur sehingga membentuk sebuah dinding penopang. Selama beberapa decade, SPSW menjadi salah satu system pengaku yang menjanjikan untuk menahan beban lateral pada struktur utama maupun struktur penggantung khususnya pada struktur gedung tingkat tinggi. Diharapkan dengan pemakaian SPSW dapat menahan gaya gempa yang terjadi di daerah Surabaya.
Pada perhitungan bangunan Gedung Fakultas Farmasi mengacu pada Spesifikasi Untuk Bangunan Gedung Baja Struktural SNI 1729:2015, Tata Cara Perencanaan Struktur Baja Untuk Bangunan Gedung SNI 03-1729-2002, Tata Cara Perencanaan Ketahanan Gempa Untuk Struktur Bangunan Gedung dan Non Gedung SNI 1726:2012, ASCE 7-2002, Beban Minimum Untuk Perancangan Bangunan Gedung dan Struktur Lain SNI 1727:2013, Persyaratan Beton Struktural Untuk Bangunan Gedung, AISC Steel Design-31, AISC Steel Design-20, dan Peraturan Pembebanan Indonesia Untuk Bangunan Gedung PPIUG 1983.
Dari analisa dan hasil perencanaan diperoleh hasil yaitu : Tebal pelat atap, kelas, kantor, koridor dan parkir 9 cm dengan pelat bondek. Dimensi balok induk HC 882x300x12x20 pada bentang 8,1 dan 8,6 m. Dimensi kolom lantai 1-5 menggunakan profil RCFT HSS 700x700x28x28, kolom lantai 6-10 menggunakan profil RCFT HSS 550x550x28x28, kolom 11-atap menggunakan profil RCFT HSS 450x450x28x28. Ketebalan SPSW 3 mm. Perencanaan mutu sambungan digunakan mutu fub A490. Pondasi mengguunakan tiang pancang dengan diameter Ø60 cm pada kedalaman 30 m.
===============================================================================================================================
Surabaya as the second largest city in Indonesia, experienced rapid development, both physically and non-physically. With an area of 326.36 km2 (BPS, 2018). Then there will be a huge loss in terms of material and fatalities if there is no prevention and anticipation of earthquakes. The AIirlangga Campus C Faculty of Pharmacy Building, then called the Faculty of Pharmacy Building, was previously built with reinforced concrete material with a Special Moment Resisting Frame Structure (SRPMK) system consisting of 14 floors. This building functions as an educational facility with a dense usage. Anticipation of earthquakes is needed in the construction of this building.
In this final project planning the Faculty of Pharmacy Building was modified from reinforced concrete structures to steel using Hexagonal Castellated beams with Steel Plate Shear Wall (SPSW) stiffening systems. Hexagonal Castellated beams is expected to be able to meet the needs of a wide range of rooms with smaller profiles. Stell Plate Shear Wall (SPSW) is one of the lateral load restraint systems consisting of a dense vertical steel plate that links beams and columns around it and the atmosphere along the height of the structure to form a support wall. SPSW has become one of the stiffening systems to hold lateral loads on the main structure and hanging structures especially on high-rise building structures. It is expected that using SPSW can withstand the forces of earthquakes that occur in the Surabaya area.
In calculating the building, the Faculty of Pharmacy Building refers to the Specifications for Bangunan Gedung Baja Struktural SNI 1729:2015, Tata Cara Perencanaan Struktur Baja Untuk Bangunan Gedung SNI 03-1729-2002, Tata Cara Perencanaan Ketahanan Gempa Untuk Struktur Bangunan Gedung dan Non Gedung SNI 1726:2012, ASCE 7-2002, Beban Minimum Untuk Perancangan Bangunan Gedung dan Struktur Lain SNI 1727:2013, AISC Steel Design-31, AISC Steel Design-20, and Indonesian Loading Regulations for Buildings Building PPIUG 1983.
From the analysis and the planning obtained results, namely: Thickness of roof plates, classes, offices, corridors and parking 9 cm with bondek plates. The dimensions of the main beam HC 882x300x12x20 at spans 8.1 and 8.6 m. The dimensions of the 1-5 floor columns use the HSS 700x700x28x28 RCFT profile, the 6-10 using the HSS 550x550x28x28 RCFT, the 11-roof using the RCFT HSS 450x450x28x28. 3 mm SPSW thickness. Connection used A490 fub. The foundation uses a pile Ø60 cm at a depth of 30 m.

Item Type: Thesis (Other)
Additional Information: RSS 690.73 Dew m-1 2019
Uncontrolled Keywords: struktur baja, castellated, steel plate
Subjects: T Technology > TA Engineering (General). Civil engineering (General)
T Technology > TA Engineering (General). Civil engineering (General) > TA645 Structural analysis (Engineering)
T Technology > TH Building construction > TH1095 Earthquakes and building
Divisions: Faculty of Civil, Environmental, and Geo Engineering > Civil Engineering > 22201-(S1) Undergraduate Theses
Depositing User: Dovan Alfano Dewana
Date Deposited: 10 Jul 2024 06:53
Last Modified: 10 Jul 2024 06:53