Evaluasi Karakteristik Dosimetri Material Bolus untuk Radioterapi menggunakan Radiasi Berkas Foton

Carina, Chycilia Clara Chandra (2019) Evaluasi Karakteristik Dosimetri Material Bolus untuk Radioterapi menggunakan Radiasi Berkas Foton. Other thesis, Institut Teknologi Sepuluh Nopember.

[thumbnail of 01111540000053-Undergraduate_Thesis.pdf] Text
01111540000053-Undergraduate_Thesis.pdf
Restricted to Repository staff only

Download (3MB) | Request a copy

Abstract

Penelitian ini bertujuan untuk mengkarakterisasi dan mengevaluasi bolus material yang disintesis menggunakan Karet Alam, Lilin Parafin, Play-Doh, dan Plastisin untuk terapi radiasi menggunakan sinar foton. Untuk mengetahui kesamaan material bolus dengan organ tubuh dilakukan uji densitas fisik dan densitas elektron atau Relative Electron Density (RED) dengan menggunakan CT-scan. LINAC 2300iX dengan energi 6 dan 10 MV digunakan untuk mengevaluasi faktor transmisi, koefisien atenuasi, software Eclipse untuk mengukur persentase dosis permukaan. Semua bolus disintesis dengan ukuran 11 × 11 cm2 dan variasi ketebalan 0,5, 1, dan 1,5 cm. CT-Scan digunakan untuk mengukur kerapatan elektron relatif (RED), Hasil penelitian menunjukan nilai RED semua bahan bolus sesuai dengan ketentuan bolus sebagai kompensasi jaringan tubuh manusia dan material bolus yang disintesis mampu merubah area build up mendekati permukaan target. Terlihat juga bahwa penggunaan material bolus dapat meningkatkan persentase dosis permukaan pada semua energi foton. Selanjutnya faktor transmisi meningkat sebanding dengan penurunan koefisien atenuasi massa untuk semua variasi ketebalan.
=================================================================================================================================
This study aims to characterize and evaluate the bolus of materials synthesized using Natural Rubber, Paraffin Wax, Play-Doh, and Plasticine for radiation therapy using a photon beam. To determine the similarity of bolus material with body organs, physical density, and electron density or Relative Electron Density (RED) tests were carried out using CT scans. LINAC 2300iX with energies of 6 and 10 MV is used to evaluate the transmission factor, attenuation coefficient, whereas Eclipse software used to measure the percentage of surface dose (PSD). All boluses were synthesized with a size of 11 × 11 cm2 and variations in the thickness of 0.5, 1, and 1.5 cm. The results showed that the RED value of all bolus materials in accordance with the provisions of bolus as compensation for human body tissue and synthesized bolus material capable of changing the build-up area shifted to the surface. It is also seen that the use of bolus material can increase the percentage of surface dose in all photon energies. Furthermore, the transmission factor increases in proportion to the decrease in the mass attenuation coefficient for all thickness variations.

Item Type: Thesis (Other)
Uncontrolled Keywords: Bolus, plastisin, RED, PSD
Subjects: Q Science > QC Physics > QC100.5 Measuring instruments (General)
Q Science > QR Microbiology > QR 201.T84 Tumors. Cancer
Divisions: Faculty of Natural Science > Physics > 45201-(S1) Undergraduate Thesis
Depositing User: Chycilia Clara Chandra Carina
Date Deposited: 20 Jul 2026 01:15
Last Modified: 20 Jul 2026 01:15
URI: http://repository.its.ac.id/id/eprint/67251