Munir, Misbachul (2019) Pengaruh Arah Potong terhadap Kekasaran Permukaan dan Pengaruh Bentuk Spesimen terhadap Kekuatan Tarik Material Stent. Other thesis, Institut Teknologi Sepuluh Nopember.
|
Text
02111440000112-Undergraduate_Theses.pdf Restricted to Repository staff only Download (5MB) | Request a copy |
Abstract
Studi numerik pada stent telah banyak dilakukan dan hasil studi ini sangat dipengaruhi oleh sifat material yang digunakan, yaitu sifat material logam stent dan pembuluh darah. Sifat material yang digunakan untuk pembuluh darah mengalami banyak perkembangan dan sangat membantu praktisi dalam membuat desain stent. Sebaliknya, sifat material logam stent tidak banyak mengalami perubahan. Bila ditinjau dari proses manufakturnya, material penyusun stent dibentuk dari tabung tipis dan proses ini menyebabkan material tersebut memiliki perilaku anisotropi. Oleh karena itu, perlu dilakukan investigasi untuk mengetahui pengaruh perilaku tersebut. Eksperimen dilakukan dengan dua metode, yakni dengan uji tarik intermittent dan uji tarik aksial-tangensial. Uji tarik intermittent dilakukan dengan mengambil spesimen mengikuti orientasi arah potong lateral (0o arah cold rolling) dan longitudinal (90o arah cold rolling) untuk melihat pengaruhnya terhadap kekasaran permukaan. Terdapat tiga kondisi permukaan untuk mendekati kondisi perlakuan stent sesungguhnya sehingga perlakuan pada masing-masing orientasi arah potong spesimen; bare, etched, dan electropolished. Nilai kekasaran permukaan diambil pada tiga kondisi regangan; 2,5 mm, 5 mm, dan 7,5 mm. Nilai kekasaran permukaan di dapatkan melalui observasi mikroskop digital, dengan mengambil parameter kekasaran permukaan rata-rata. Uji tarik aksial-tangensial diambil menggunakan spesimen aksial dan ring yang dibentuk dari tabung tipis yang tebalnya 1 mm untuk mengetahui pengaruh bentuk spesimen uji tarik terhadap kurva hubungan tegangan-regangan material dasar penyusun stent. Hasil yang didapatkan dari pengujian menunjukkan bahwa orientasi arah potong longitudinal memiliki nilai perubahan kekasaran permukaan yang paling rendah. Nilai perubahan kekasaran permukaan yang paling rendah ditunjukkan oleh spesimen electropolished, sebesar 7%. Hasil uji tarik aksial-tangensial menunjukkan bahwa spesimen ring memiliki kekuatan tarik yang lebih besar dibandingkan dengan spesimen aksial. Nilai ultimate tensile strength yang didapatkan untuk spesimen ring dan aksial adalah 688 MPa dan 406 MPa.
===================================================================================================================================
The result on numerical study of stent is highly determined by the material property of stent and blood vessel used. Material property of blood vessel used in this study has developed and carry through manufacturer on designing stent. Otherwise, material property of stent used on this study didn’t altered. According to manufacturing process, stent is manufactured from thin tube and this process could altered into anisotropy behaviour. Hence, it is need to perform investigation to discover the effect of its behaviour. Experiment performed in two ways, there are intermittent tensile test and axial-tangential tensile test. Intermittent tensile test performed by taking specimen respect to lateral cutting orientation (0o cold rolling direction) and longitudinal (90o cold rolling direction) to discover the effect on surface roughness. There are three surface treatment condition that performed on each specimen lateral and longitudinal; bare, etched, and electropolished. Surface roughness value obtained on three point; 2,5 mm , 5 mm and 7,5 strain. Those value obtained by digital microscope and the parameter used is average surface roughness. Axial-tangential tensile test is performed by ring and axial specimen taken from 1 mm thin tube of stainless steel 316 to discover its effect on stress-strain curve of stent material. The result of this experiment was longitudinal cutting orientation has the lowest value of surface roughness. The lowest change of surface roughness was electropolished specimen, 7% in change compared to initial loading. Axial-tangential tensile test shown ring specimen has higher value of tensile strength than axial specimen, 688 MPa compared to 406 MPa. And it is indicate different behaviour on plastic strain above 7%.
| Item Type: | Thesis (Other) |
|---|---|
| Uncontrolled Keywords: | Orientasi arah potong, kekasaran permukaan, uji tarik intermittent, uji tarik aksial-tangensial |
| Subjects: | T Technology > TA Engineering (General). Civil engineering (General) |
| Divisions: | Faculty of Industrial Technology > Mechanical Engineering > 21201-(S1) Undergraduate Thesis |
| Depositing User: | Munir Misbachul |
| Date Deposited: | 21 Jul 2026 06:31 |
| Last Modified: | 21 Jul 2026 06:31 |
| URI: | http://repository.its.ac.id/id/eprint/68354 |
Actions (login required)
![]() |
View Item |