Potensi Energi Baru Terbarukan (EBT) saat ini belum dimanfaatkan secara maksimal. Energi yang bersumber dari matahari adalah salah satu sumber energi yang telah dimanfaatkan secara luas saat ini di beberapa Negara di dunia, yang dalam skala besar telah digunakan sebagai pembangkit listrik. Kolektor surya merupakan suatu alat penukar kalor yang berfungsi untuk mengubah energi radiasi matahari menjadi bentuk energi panas untuk memanaskan fluida kerja, misalnya air dan udara. Berbagai metode telah dilakukan untuk meningkatkan kinerja dari kolektor surya, diantaranya adalah menggunakan reflektor plat datar. Reflektor digunakan untuk memantulkan sinar matahari yang menyebar agar dapat fokus menuju ke permukaan kolektor surya dan akhirnya dapat menambah kinerja dari kolektor surya tersebut. Studi analitik dan eksperimen pada penelitian ini adalah untuk melihat kinerja dari sebuah kolektor surya tipe sinusoidal dengan dan tanpa penambahan reflektor pada kondisi debit air yang bervariasi. Variasi debit air yang digunakan adalah 18 liter/jam, 20 liter/jam dan 22 liter/jam. Penelitian secara analitik dilakukan untuk dapat mengetahui sudut reflektor terbaik pada kolektor surya. Variasi sudut reflektor pada penelitian ini yaitu tanpa reflektor, 30˚, 40˚, 50˚, 60˚, dan 70˚. Reflektor diletakkan pada kedua sisi samping dari kolektor surya. Variasi reflektor dilakukan untuk mengetahui sudut reflektor terbaik pada kolektor surya sehingga diharapkan dapat meningkatkan performansi dari kolektor surya. Dari hasil penelitian secara analitik untuk tanggal 15 Agustus diperoleh hasil untuk total intensitas radiasi matahari harian tertinggi adalah pada kondisi sudut reflektor 40˚ yaitu sebesar 1720,01 W/m2. Kemudian untuk hasil eksperimen diperoleh nilai rata-rata Qu harian paling besar ada pada kondisi debit air 22 liter/jam dengan variasi penambahan reflektor 40˚ yaitu sebesar 170,389 Watt, sedangkan untuk nilai efisiensi paling besar ada pada kondisi debit air 22 liter/jam dengan variasi penambahan reflektor 40˚ yaitu sebesar 61,2%.
================================================================================================================================
The potential of New Renewable Energy (EBT) is currently not maximally utilized. The Energy from the sun is one of the energy sources that has been widely used today in several countries in the world, which on a large scale has been used as a power plant. Solar collector is a heat exchanger that can to convert the energy of solar radiation into the heat energy to heat the working fluid, such as water and air. Many methods have been carried out to improve the performance of solar collectors, including using flat plate reflectors. The reflector is used to reflect diffuse sunlight so that it can focus towards the surface of the solar collector and can finally increase the performance of the solar collector. The reflector is used to reflect the light from the sun so that it can focus towards the surface of the solar collector and can increase the performance of the solar collector. The analysis and experiment in this study was to determine the performance of sinusoidal solar collector types with and without the addition of reflectors in different flow rate conditions. The variation of flow rates is 18 liters / hour, 20 liters / hour and 22 liters / hour. Analytical studies are conducted to find out the best reflector angle from the solar collectors. The reflector angle variation in this study is without reflector, 30˚, 40˚, 50˚, 60˚, and 70˚. The reflector is placed on both sides of the solar collector. The variation of the reflector is done to determine the best reflector angle from the solar collector so that it can improve the performance of the solar collector. From the results of an analytical study for the 15th of August the results for the highest total intensity of daily solar radiation were at the 40˚ reflector angle at 1720.01 W/m2. Then for the experimental results the highest average daily of qu value is found 170,389 Watt at the flow rate 22 liters / hour with variations in the addition of a 40˚ reflector angle. And for the highest efficiency value, 61.2% is in the condition of 22 liters / hour water discharge with variations in the addition of reflectors.

Item Type: Thesis (Masters)
Uncontrolled Keywords: kolektor surya sinusoidal, reflektor, total intensitas radiasi matahari, performansi
Subjects: T Technology > TJ Mechanical engineering and machinery > TJ810.5 Solar energy
Divisions: Faculty of Industrial Technology > Mechanical Engineering > 21101-(S2) Master Thesis