Analisis Reliability Dengan Menggunakan Metode Fault Tree Analysis Berbasis Genetic Algorithm Pada Crude Charge Heater di Unit FOC II PT Pertamina (Persero) RU IV Cilacap

Wijaya, Abdul Lathif (2019) Analisis Reliability Dengan Menggunakan Metode Fault Tree Analysis Berbasis Genetic Algorithm Pada Crude Charge Heater di Unit FOC II PT Pertamina (Persero) RU IV Cilacap. Other thesis, Institut Teknologi Sepuluh Nopember.

[thumbnail of 02311540000123-Undergraduate_Thesis.pdf] Text
02311540000123-Undergraduate_Thesis.pdf
Restricted to Repository staff only

Download (2MB) | Request a copy

Abstract

PT Pertamina (Persero) RU IV Cilacap merupakan salah satu unit pengolahan minyak bumi menjadi bahan bakar minyak (BBM) dan non bahan bakar minyak (non-BBM) yang berada di jawa tengah. Salah satu unit pengolahan minyak bumi yang berada pada PT Pertamina RU IV Cilacap merupakan Crude Charge Heater. Agar didapatkan hasil yang optimal, keandalan dari suatu komponen pada proses produksi sangat berpengaruh terhadap kualitas dan kuantitas produk yang dihasilkan. Analisa reliability merupakan salah satu metode yang banyak digunakan. Selain itu metode optimasi digunakan untuk mendapatkan harga terendah dari maintenance tanpa mengurangi kualitas dari keandalan komponen tersebut. Pada penelitian kali ini dilakukan penelitian untuk menentukan harga maintenance 10 tahun kedepan. Setelah dilakukan perhitungan didapatkan hasil reliability 0,9 dengan waktu beroperasi paling kecil pada PI-024 sebesar 550 jam dan dengan waktu beroperasi paling lama pada PV-007 dengan nilai reliability 0,7 pada saat beroperasi selama 6800 jam. Untuk proses optimisasi didapatkan hasil optimal pada rentang waktu 5 tahun sekali dengan menggunakan batasan reliability sebesar 0,7-0,9 dan didapatkan selisih harga sebesar 5.411 USD dimana waktu perbaikan secara berkala terpendek pada PI-024 sebesar 894 jam dan waktu terpanjang pada FSL-021 sebesar 6340 jam.
===============================================================================================================================
PT Pertamina (Persero) RU IV Cilacap is one of the processing units of petroleum into fuel oil and non-fuel in Central Java. Crude charge heater is one of the processing in PT Pertamina RU IV Cilacap. In order to obtain optimal result, the reliability of a component in the production process is very influential on the quality using fault tree analysis and quantity of the product. Reliability analysis is one method that is widely used. In addition, optimization methods are used to get the lowest price from maintenance without reducing the quality of the reliability components. This research was conducted to determine maintenance prices for the next 10 years. After the calculation, reliability is 0,9 with the smallest operating time on PI-024 of 550 hours and the longest operating time in PV-007 with a reliability value of 0,7 when operating for 6800 hours. For the optimization process the optimal results are obtained once every 5 years using the reliabilty limit of 0,7-0,9 and the price difference is 5.411 USD where the shortest periodic repair time on PI-024 is 894 hours and the longest time on FSL-021 for 6340 hours.

Item Type: Thesis (Other)
Uncontrolled Keywords: Fault tree analysis, Genetic Algorithm, Optimization, Reliability
Subjects: T Technology > TA Engineering (General). Civil engineering (General) > TA169 Reliability (Engineering)
T Technology > TS Manufactures > TS174 Maintainability (Engineering) . Reliability (Engineering)
Divisions: Faculty of Industrial Technology > Physics Engineering > 30201-(S1) Undergraduate Thesis
Depositing User: Abdul lathif wijaya
Date Deposited: 21 Jul 2026 08:13
Last Modified: 21 Jul 2026 08:13
URI: http://repository.its.ac.id/id/eprint/69959