Gomosma, Godwin (2019) Perbandingan Performansi Sensor SPR (Surface Plasmon Resonance) Berdasarkan Konfigurasi Otto dan Konfigurasi Kretschmann. Other thesis, Institut Teknologi Sepuluh Nopember.
|
Text
02311540000112-Undergraduate_Thesis.pdf Restricted to Repository staff only Download (2MB) | Request a copy |
Abstract
Pada penelitian ini, dilakukan simulasi untuk mengetahui performansi SPR (Surface Plasmon Resonance) berbasis Konfigurasi Otto dan Konfigurasi Kretschmann. SPR merupakan eksitasi gelombang plasmon pada suatu permukaan logam dan media dielekterik. Eksitasi tersebut dapat dilakukan menggunakan prisma, logam dan material dielektrik yang disusun dengan struktur geometri Kretschmann atau Otto. Pada konfigurasi Otto, lapisan dielektrik berada di antara prisma dan lapisan logam. Pada konfigurasi Kretschmann, lapisan logam berada diantara prisma dengan lapisan dielektrik. Dua konfigurasi tersebut umumnya digunakan pada SPR tipe prisma. Dewasa ini, SPR menjadi salah satu topik yang sering diteliti dalam pembuatan sensor karena akurasinya yang baik, sensitivitas yang tinggi dan sifatnya yang real time monitoring. Hasil dari simulasi memperlihatkan bahwa terdapat perbedaan antara Konfigurasi Otto dan Konfigurasi Kretschmann. Dari perbandingan perfomansi dari jenis logam yang digunakan, Konfigurasi Otto memiliki FWHM yang lebih baik sehingga memiliki akurasi yang bagus. Selanjutnya dilakukan simulasi SPR sebagai sensor untuk memeriksa kadar larutan gula dan etanol untuk dibangidngkan sensitivitasnya Konfigurasi Kretschmann memiliki performansi yang baik sebagai sensor konsentrasi larutan etanol karena memiliki sensitivitas sebesar 181,958 º/RIU, sedangkan Konfigurasi Otto memiliki performansi yang baik sebagai sensor konsentrasi larutan gula karena sensitivitas 167,7156 º/RIU.
================================================================================================================================
This study presents a simulation to evaluate the performance of Surface Plasmon Resonance (SPR) sensors based on the Otto and Kretschmann configurations. SPR is a phenomenon involving the excitation of plasmon waves at the interface between a metal surface and a dielectric medium. This excitation is achieved using a prism, a metal layer, and a dielectric material arranged in either the Otto or Kretschmann configuration. In the Otto configuration, the dielectric layer is positioned between the prism and the metal layer, whereas in the Kretschmann configuration, the metal layer is located between the prism and the dielectric layer. These two configurations are widely employed in prism-based SPR systems. Due to their high accuracy, excellent sensitivity, and capability for real-time monitoring, SPR sensors have become a prominent research topic in sensing applications. The simulation results demonstrate distinct performance differences between the Otto and Kretschmann configurations. Based on the comparison of the metals used, the Otto configuration exhibits a narrower Full Width at Half Maximum (FWHM), indicating higher measurement accuracy. Furthermore, the SPR simulations were applied to detect the concentrations of sugar and ethanol solutions. The Kretschmann configuration showed superior performance as an ethanol concentration sensor, achieving a sensitivity of 181.958°/RIU, whereas the Otto configuration demonstrated better performance for sugar concentration sensing, with a sensitivity of 167.7156°/RIU.
| Item Type: | Thesis (Other) |
|---|---|
| Uncontrolled Keywords: | Surface Plasmon Resonance, Kretschmannn, Otto |
| Subjects: | Q Science > QC Physics > QC100.5 Measuring instruments (General) |