Perdana, Fajar Putra (2019) Rancang Bangun Sensor Aliran Udara Menggunakan Serat Optik Singlemode-Multimode-Singlemode (Sms). Other thesis, Institut Teknologi Sepuluh Nopember.
Preview |
Text
02311745000031-Undergraduate_Theses.pdf Download (1MB) | Preview |
Abstract
Saat ini serat optik dikembangkan menuju ke arah sistem sensor yang bisa digunakan untuk pengukuran berbagai jenis variabel. Banyak penelitian yang telah mengembangkan sensor berbasis serat optik sebagai sensor serbaguna. Pada penelitian ini telah dilakukan rancang bangun sensor aliran udara menggunakan serat optik singlemode-multimode-singlemode (SMS) yang mampu mendeteksi variasi kecepatan aliran udara pada fan. Sensor yang diuji memiliki panjang variasi multimode 1 cm, 2 cm dan 3 cm. Sedangkan besarnya tengangan masukan pada fan meliputi 4 V, 6 V, 8 V, 10 V, 12 V, 14 V, 16 V, dan 18 V. Dengan kecepatan flow nya dari setiap tegangan tersebuat yang telah diukur menggunakan anemometer yaitu sebesar 0.99 m/s, 1.96 m/s, 2.96 m/s, 3.83 m/s, 4.68 m/s, 5.41 m/s, 5.92 m/s dan 6.59 m/s. Pengujian sensor dilakukan dengan cara mengukur perubahan daya keluaran setiap variasi panjang serat optik multimode dengan menggunakan variasi aliran udara yang telah ditentukan. Aliran udara diletakkan tepat pada bagian multimode. Pada penelitian ini didapatkan hasil bahwa sensor terbaik yang mampu mengukur kecepatan aliran udara adalah sensor dengan panjang multimode step index 1 cm pada rentang aliran udara 1.96 m/s – 6.59 m/s dengan sensitivitas 1.237 ((dBm)/(m/s), dan kinerja sensor aliran udara terbaik menggunakan multimode coreless adalah dengan panjang sensor 1 cm pada rentang aliran udara 0 m/s – 4.68 m/s dengan sensitivitas 0.2002 ((dBm)/(m/s).
============================================================
At this time, optical fiber was developed in the direction of a sensor system that could be used to measure various types of variables. Many studies have developed optical fiber-based sensors as multipurpose sensors. In this research, an air flow sensor design has been carried out using singlemode-multimode-singlemode (SMS) optical fiber which is able to detect variations in air flow velocity on the fan. The sensor tested has a multimode variation length of 1 cm, 2 cm and 3 cm. While the amount of input voltage on the fan includes 4 V, 6 V, 8 V, 10 V, 12 V, 14 V, 16 V, and 18 V. With the flow velocity of each voltage that has been measured using an anemometer that is equal to 0.99 m / s, 1.96 m / s, 2.96 m / s, 3.83 m / s, 4.68 m / s, 5.41 m / s, 5.92 m / s and 6.59 m / s. Sensor testing is done by measuring the change in output power of each multimode optical fiber length variation by using predetermined air flow variations. The air flow is placed right in the multimode section. In this study, the results showed that the best sensor capable of measuring air flow velocity was a sensor with a multimode step index of 1 cm in the air flow range of 1.96 m / s - 6.59 m / s with a sensitivity of 1237 ((dBm) / (m / s), and the best air flow sensor performance using multimode coreless is with a sensor length of 1 cm in the air flow range of 0 m / s - 4.68 m / s with a sensitivity of 0.2002 ((dBm) / (m / s).
Item Type: | Thesis (Other) |
---|---|
Uncontrolled Keywords: | Sensor Aliran Udara, serat optik SMS, Multimode coreless, Multimode step index |
Subjects: | T Technology > T Technology (General) > T55 Industrial Safety T Technology > T Technology (General) > T57.62 Simulation |
Divisions: | Faculty of Industrial Technology > Physics Engineering > 30201-(S1) Undergraduate Thesis |
Depositing User: | Perdana Fajar Putra |
Date Deposited: | 17 Oct 2024 04:04 |
Last Modified: | 17 Oct 2024 04:04 |
URI: | http://repository.its.ac.id/id/eprint/70160 |
Actions (login required)
View Item |