Kaji Eksperimen Portable Cool Box Menggunakan TEC1-12706 Tunggal dengan Sistem Pendinginan Air

Hidayaha, Miftakhul Reza (2019) Kaji Eksperimen Portable Cool Box Menggunakan TEC1-12706 Tunggal dengan Sistem Pendinginan Air. Diploma thesis, Institut Teknologi Sepuluh Nopember.

[thumbnail of 10211600000036-Non_Degree.pdf] Text
10211600000036-Non_Degree.pdf
Restricted to Repository staff only

Download (6MB) | Request a copy

Abstract

Seperti yang telah kita ketahui penggunaan pendingin ruangan dan lemari pendingin sudah sangat menjamur di masyarakat, baik di perkantoran, pertokoan, hingga penggunaan pada rumah tangga. Namun, penggunaan pendingin ruangan dan lemari pendingin dianggap kurang ramah lingkungan karena menggunakan unsur refrigerant sebagai media pendinginnya, yang mana dapat merusak lapisan ozon bumi. Oleh karena itu dibuat sistem pendinginan ramah lingkungan dengan menggunakan rangkaian thermoelectric TEC1-12706, waterblock, dan fan heatsink yang dirangkai menjadi satu sebagai media dan sumber dingin pada cool box. Cool Box yang telah terisolasi dengan polystyrene foam dan aluminium. Berdasarkan hasil pengukuran pada thermocouple thermometer selama 2 jam pengujian yang diambil secara berkala setiap 3 menit pengujian, hasil data temperatur terendah dari sumber pendinginan adalah 2.9ᵒC. Sedangkan untuk hasil perhitungan kesetimbangan termal yang dihitung pada kondisi steady state didapat nilai kuat arus sebesar 0.5826 ampere.
===================================================================================================================================
The use of air conditioner and refrigerator has been spreading in the community, whether in offices, stores, or household uses. However, the use of air conditioner and refrigerator is considered as less friendly to the environment because of the use of certain refrigerant element as a cooling medium, which can damage the earth’s ozone. Therefore, an environmentally friendly cooling system is made using a series of thermoelectric TEC1-12706, waterblock, and fan heatsink which are compiled together as a medium and cold source in the cool box, a cool box which has been insulated with polystyrene foam and aluminum. Based on the measurement results on the thermocouple thermometer for 2 hours of testing taken periodically every 3 minutes of testing, the lowest temperature data from the cooling source is 2.9ᵒC. While for the calculation of thermal equilibrium at steady state, the value of electric current is 0.5826 ampere.

Item Type: Thesis (Diploma)
Uncontrolled Keywords: ramah lingkungan, cool box, thermoelectric, waterblock, sistem pendinginan, dan steady state.
Subjects: T Technology > TJ Mechanical engineering and machinery > TJ263 Heat exchangers
Divisions: Faculty of Vocational > Mechanical Industrial Engineering (D4)
Depositing User: Hidayah Miftakhul Reza
Date Deposited: 13 Aug 2026 03:22
Last Modified: 13 Aug 2026 03:22
URI: http://repository.its.ac.id/id/eprint/70182