Sistem pemantauan arus dan tegangan digunakan untuk
mengetahui aliran daya yang bersumber dari PV, battery dan PLN ke
mobil listrik / electric vehicle. Webserver difungsikan agar pemantauan
bisa dilakukan secara online. Data logger digunakan untuk mengetahui
trend aliran daya dan energi pada charging station. Data realtime dari
charging station dikirimkan ke interface web setiap 10 detik sekali, data
logger yang dipakai adalah database MySQL.
Sensor untuk mengukur tegangan AC menggunakan ZMP101B
yang diletakkan di tegangan output inverter dengan range area
pengukuran maksimal 220 volt AC. Sensor untuk mengukur tegangan
DC menggunakan voltage divider yang diletakkan di antara MPPT,
battery dan inverter dengan range area pengukuran maksimal 24 volt
DC. Sensor untuk mengukur arus DC keluaran dari MPPT
Menggunakan sensor LA 55-p dengan area pengukuran maksimal 50A.
Sensor arus AC untuk mengukur keluaran arus inverter menggunakan
sensor LA 55-p dengan maksimal area pengukuran 10 A. kecepatan
dalam pengambilan tegangan DC dan arus DC adalah 1 KHz dan
kecepatan dalam pengambilan tegangan AC dan arus AC adalah 8,9
KHz.
Error pengukuran tegangan DC hingga 24 V dengan error
maksimal 8,6% dan arus DC hingga 10 A dengan error maksimal 2.2%,
sedangkan tegangan AC hingga 220V dengan error maksimal 9,8% dan
arus AC hingga 10A dengan error maksimal 3,09%.

===============================================================================================

Current and voltage monitoring system is used to find out the
flow of power from the PV, battery and PLN to electric vehicle/electric
car. A webserver enabled so that monitoring can be done online. The
data logger is used to find out the trend of power and energy flow in the
charging station. Realtime data from the charging station is sent to a
web interface every 10 seconds, the data logger used is MySQL
database.
Sensor for measuring AC voltages using ZMP101B which is
placed on the output voltage of the inverter with maximum
measurements of the area range 220 volts AC voltage to measure Sensor.
DC using a voltage divider placed between the MPPT, battery and
inverter with maximum measurements of the area range 24 volt DC.
Sensor for measuring DC current output from the sensor using the
MPPT LA 55-p 50A maximum measurement area. AC current sensors to
measure the output current of the inverter using the sensor LA 55-p with
a maximum area of measurement 10 a. DC voltage pick-up speed and
current DC is 1 KHz and the speed in making voltage AC and AC is 8, 9
KHz.
DC voltage measurement errors up to 24 V with maximum
error of 8.6% and DC currents up to 10 A with a maximum error of
2.2%, while the AC voltage to 220V with a maximum error of 9.8% and
a current of AC of up to 10A with maximum error of 3.09%.

Item Type: Thesis (Undergraduate)
Additional Information: RSE 621.319 Muk s
Uncontrolled Keywords: Sistem monitoring; charging station; web server; data logger
Subjects: T Technology > TK Electrical engineering. Electronics Nuclear engineering > TK3226 Transients (Electricity). Electric power systems. Harmonics (Electric waves).
Divisions: Faculty of Electrical Technology > Electrical Engineering > 20201-(S1) Undergraduate Thesis
Depositing User: - Taufiq Rahmanu
Date Deposited: 01 Oct 2019 02:23
Last Modified: 01 Oct 2019 02:23
URI: http://repository.its.ac.id/id/eprint/70919

Actions (login required)

View Item View Item