Pengaruh pencucian membran dan penentuan tegangan optimum pada proses elektrodialisis (ED) dalam desalinasi air payau menjadi air tawar

Elsandari, Aprilya (2015) Pengaruh pencucian membran dan penentuan tegangan optimum pada proses elektrodialisis (ED) dalam desalinasi air payau menjadi air tawar. Undergraduate thesis, Institut Teknologi Sepuluh Nopember.

[thumbnail of 3311100008-Undergaduate_Thesis.pdf]
Preview
Text
3311100008-Undergaduate_Thesis.pdf

Download (2MB) | Preview

Abstract

Teknologi membran yang sedang dikembangkan untuk desalinasi air payau adalah elektrodialisis (ED). Selama proses elektrodialisis terdapat gangguan berupa scale pada membran ED yang mempengaruhi hasil penelitian terdahulu. Selain itu, penelitian terdahulu tentang tegangan optimum dalam ED masih belum diketahui untuk desalinasi air payau menjadi air tawar. Berdasarkan hal tersebut maka dilakukan penelitian mengenai proses elektrodialisis dalam desalinasi air payau menjadi air tawar yang fokus pada pengaruh pencucian membran dan tegangan. Tujuan dari penelitian ini adalah menganalisis pengaruh pencucian membran dan tegangan optimum pada proses elektrodialisis dalam desalinasi air payau menjadi air tawar. Penelitian ini dilakukan menggunakan umpan air payau (TDS 2000±100 mg/L) dalam skala laboratorium. Variasi yang digunakan adalah pencucian membran yaitu pencucian dengan Chemical Cleaning Agents (CCA) dan tanpa CCA serta tegangan yaitu 6, 9, dan 12 V. Parameter yang diuji meliputi TDS, salinitas, konsentrasi Cl-, dan pH. Hasil dari penelitian ini didapatkan pencucian dengan CCA tidak memberikan pengaruh pada kinerja desalinasi bahkan memiliki penurunan removal lebih besar daripada pencucian tanpa CCA pada semua parameter uji dan variasi tegangan. Tegangan optimum untuk elektrodialisis pada penelitian ini didapatkan yaitu 9 V. Tegangan 9 V pada variasi pencucian dengan dan tanpa CCA memiliki efisien desalinasi terbesar yaitu nilai kWh/m3/% removal yang kecil. Variasi pencucian dengan CCA memiliki nilai kWh/m3/% removal sebesar 7,23 sedangkan variasi pencucian tanpa CCA sebesar 4,45. Efisiensi desalinasi yang besar adalah ketika memiliki nilai kWh/m3/% removal yang kecil dimana berarti energi minimal yang dikeluarkan digunakan untuk menyisihkan parameter secara efisien.

=======================================================================================================

Membrane technology that is developed for desalination of brackish water is electrodialysis (ED). During electrodialysis process, there are some inhibitors as scale of ED membrane that affects the results of previous studies. Besides, previous studies about optimum voltage of ED still unknown to desalinate brackish water into become fresh water. Based of that problems, this research analyzes about electrodialysis process in desalination of brackish water into become fresh water which focused on effects of membrane cleansing and voltage. Purposes of this study are to analyze the effect of membrane cleansing and optimum voltage of ED process in desalination of brackish water into become fresh water. This study uses brackish water (TDS 2000±100 mg/L) on a laboratory scale. Variations of membrane cleansing which are cleaned with Chemical Cleaning Agents (CCA) and without CCA and variatons of voltage are 6, 9, and 12 V. Parameters in this study are TDS, salinity, Cl- concentration, and pH. The result of this study was found that membrane cleansing with CCA not only had no effect on performance of desalination but also had greater decrease of removal than cleansing without CCA in all parameters and voltage variations. The optimum voltage for ED in this study was 9 V. Variation with 9 V in membrane cleansing with CCA and without CCA has the greatest efficiency of desalination that the kWh/m3/% removed value was the least. Variation membrane cleansing with CCA has kWh/m3/% removed value 7,23 and variation without CCA has kWh/m3/% removed value 4,45. The greatest efficiency of desalination is the least kWh/m3/% removed value that means minimum energy was consumed uses to remove the parameters efficiently.

Item Type: Thesis (Undergraduate)
Additional Information: RSL 628.167 Els p
Uncontrolled Keywords: desalinasi; elektrodialisis; energi; pencucian membran; tegangan
Subjects: T Technology > TD Environmental technology. Sanitary engineering > TD430 Water--Purification.
Divisions: Faculty of Civil Engineering and Planning > Environment Engineering > 25201-(S1) Undergraduate Thesis
Depositing User: - Taufiq Rahmanu
Date Deposited: 02 Oct 2019 07:31
Last Modified: 02 Oct 2019 07:31
URI: http://repository.its.ac.id/id/eprint/70957

Actions (login required)

View Item View Item