Modifikasi Perencanaan Struktur Gedung Hotel Santika Bekasi Dengan Menggunakan King Cross Column Dan Octogonal Castellated Beam

Purboningtyas, Andira Sari (2016) Modifikasi Perencanaan Struktur Gedung Hotel Santika Bekasi Dengan Menggunakan King Cross Column Dan Octogonal Castellated Beam. Undergraduate thesis, Institut Teknologi Sepuluh Nopember.

[thumbnail of 3114105020-paperpdf.pdf]
Preview
Text
3114105020-paperpdf.pdf - Accepted Version

Download (429kB) | Preview
[thumbnail of 3114105020-presentationpdf.pdf]
Preview
Text
3114105020-presentationpdf.pdf - Presentation

Download (1MB) | Preview
[thumbnail of 3114105020-undergraduate theses.pdf]
Preview
Text
3114105020-undergraduate theses.pdf - Accepted Version

Download (4MB) | Preview

Abstract

Gedung Hotel Santika Bekasi adalah salah satu gedung yang
terbuat dari struktur beton yang terdiri dari 10 lantai dengan
tinggi 34,5 meter. Gedung Hotel Santika ini akan dimodifikasi
strukturnya dari struktur beton menjadi struktur baja dan akan
ditinggikan dari 10 lantai menjadi 14 lantai dengan tinggi 52,2
meter. Konstruksi baja yang akan digunakan adalah King Cross
Column dan Castellated Beam karena mempunyai kelebihan
daripada profil baja biasa.
Dalam Tugas Akhir ini, dilakukan perencanaan meliputi
perencanaan pelat, balok anak, tangga, lift, balok induk, kolom
dan pondasi yang mengacu pada peraturan yang berlaku
diantaranya SNI 1727:2013 tentang Beban Minimum Untuk
Perancangan Bangunan Gedung Dan Struktur Lain, SNI
1729:2015 tentang Spesifikasi Untuk Bangunan Gedung Baja
Struktural, SNI 1726:2012 tentang Tata Cara Perencanaan
Ketahanan Gempa Untuk Struktur Bangunan Gedung Dan Non
Gedung, SNI 2847:2013 Persyaratan Beton Struktural Untuk
Bangunan Gedung yang selanjutnya dituangkan dalam bentuk
gambar teknik sehingga lebih mempermudah dalam pemahaman.
Dari analisa dan perhitungan diperoleh hasil yaitu tebal
pelat atap dan pelat lantai 9 cm. Dimensi balok induk untuk
lantai atap menggunakan profil CB 495x250x8x12 dan CB
432.5x200x9x14, untuk lantai 2-5 menggunakan profil CB
712.5x300x11x15 dan CB 710x200x10x16, untuk lantai 6-9
menggunakan profil CB 710x200x10x16 dan CB
627.5x300x10x15, dan untuk lantai 10-13 menggunakan profil
CB 627.5x300x10x15 dan CB 562.5x300x9x14. Sedangkan
dimensi kolom untuk lantai 1-5 menggunakan profil KC
800x300x14x26, untuk lantai 6-9 menggunakan profil KC
700x300x13x24 dan untuk lantai 10-14 menggunakan profil KC
588x300x12x20. Dinding geser plat baja tebal 5 mm.
Perencanaan pondasi menggunakan tiang pancang prestress
yaitu Spun Piles berdiameter 600 mm. ========== Snatika Hotel in Bekasi is one of the building that made from
concrete structures which consist of 10 floors with 34.5 meters
height. This Santika Hotel will be modified from a concrete
structures to steel structure and will be raised from 10 floors to
14 floors with 52.2 meters height. Steel construction that will be
used are King Cross Column and Castellated Beam because its
have advantages than ordinary steel profiles.
In this final project, the design will include plate design, joist,
stair, lift, beam, column and fondation that refers to government
regulation such as SNI 1727:2013 about Minimum Loads for
Construction for Building and Other Structure, SNI 1729:2015
about The Specification for Steel Structural Building, SNI
1726:2012 about The Methods for Earthquake Resistance Plan
for Structure Building and non-Building, SNI 2847:2013 about
The Requirements of Structural Concrete for Building which then
poured into engineering drawings to ease the understanding.
From analysis and the calculation, the results obtained are
the roof and floor plate thickness is 9 cm. Dimension of main
beam for roof floor using CB 495x250x8x12 and CB
432.5x200x9x14, for 2nd-5th floor using CB 712.5x300x11x15 and
CB 710x200x10x16, for 6th-9th floor using CB 710x200x10x16
and CB 627.5x300x10x15, and for 10th-13rd floor using CB
627.5x300x10x15 and CB 562.5x300x9x14. While dimension of
column for 1st- 5th floor using KC 800x300x14x26, for 6th-9th floor
using KC 700x300x13x24, and for 10th-14th floor using KC
588x300x12x20. Steel plate shear wall’s thickness is 5 mm. The
foundation is planning by using prestressed concrete piles that is
600 mm diameter Spun Pile.

Item Type: Thesis (Undergraduate)
Additional Information: RSS 693.71 Pur m 3100016066619
Uncontrolled Keywords: Modifikasi, Struktur Baja, King Cross Column, Castellated Beam, Modification, Steel Structure, King Cross Column, Castellated Beam
Subjects: T Technology > TA Engineering (General). Civil engineering (General) > TA658 Structural design
Divisions: Faculty of Civil Engineering and Planning > Civil Engineering > 22201-(S1) Undergraduate Thesis
Depositing User: - Davi Wah
Date Deposited: 11 Nov 2019 06:32
Last Modified: 11 Nov 2019 06:32
URI: http://repository.its.ac.id/id/eprint/71465

Actions (login required)

View Item View Item