Low Pressure boiler feed pump (LP BFP) adalah salah satu pompa yang ada pada unit pembangkitan PLTGU, pada pengoperasian pompa ini sering terjadi permasalahan patahnya poros dimana dalam setahun bisa terjadi 8-10 masalah mengenai patah poros yang kebanyakan terjadi di sekitar ujung poros. Melihat seringnya kerusakan maka dibutuhkan evaluasi pada desain lama dan pembuatan desain baru sehingga kerusakan serupa dapat dihindari. Pada desain poros ada beberapa posisi yang biasanya terdapat konsentrasi tegangan yang tinggi yaitu pada daerah dimana ada perubahan diameter, rumah pasak, ataupun ketika adanya ulir sehingga modifikasi dilakukan pada daerah-daerah tersebut. Dari simulasi yang dilakukan didapatkan hasil bahwa distribusi tegangan pada poros desain awal rentan mengalami kegagalan pada ujung-ujung nya. Besar tegangan pada ujung poros yang berdekatan dengan impeller dan ujung poros yang berdekatan dengan motor masing-masing sebesar 425.80 MPa dan 409.98 MPa. Modifikasi geometri poros dapat mereduksi tegangan yang terjadi pada poros, besar penurunan tegangan yang dihasilkan pada ujung poros yang berdekatan dengan impeller sebesar 6.44% (425.80 MPa menjadi 398.37 MPa) sedangkan pada ujung poros yang berdekatan dengan motor sebesar 12.35% (409.98 MPa menjadi 359.31 MPa) ======================================================== Low pressure boiler feed pump (BFP LP) is one of pump that work at PLTGU generation units. When this pump operated, failure on shaft frequently happen, in a year 8-10 case about the shaft farcture on the end of shaft. Because of that evaluation of shaft deswign needed and making new design to avoid failure in the future. On shaft design, there are several position that have high stress concentration, the position are on diameter changing, keyways, thread so modification focuse on this area. From the simulation, known that the stress distribution of initial design of low pressure boiler feed pump shaft is vulnerable to failure on the end of shaft. Stress that produced on the end of shaft near the impeller and in the end of shaft that near the motor is 425.80 MPa and 409.98 MPa. Modification of shaft geometry can reduce the stress that occur on the shaft. Stress reduction on the end of shaft near the impeller is 6.44% (from 425.80 MPa become 398.37 MPa) and the end of shaft that near the motor is 12.35% (from 409.98 MPa become 359.31 MPa)

Item Type: Thesis (Undergraduate)
Additional Information: RSMt 669.142 Rah o
Uncontrolled Keywords: Optimasi, Poros, Low Pressure Boiler Feed Pump, PLTGU, Metode Elemen Hingga, ANSYS
Subjects: T Technology > TN Mining engineering. Metallurgy > TN752.I5 Steel--Heat treatment
Divisions: Faculty of Industrial Technology > Material & Metallurgical Engineering > 28201-(S1) Undergraduate Thesis
Depositing User: EKO BUDI RAHARJO
Date Deposited: 07 Nov 2019 06:23
Last Modified: 07 Nov 2019 06:23
URI: http://repository.its.ac.id/id/eprint/71637

Actions (login required)

View Item View Item