Hotel Anggrek Surabaya berada di Jalan Gubeng
Surabaya. Berdasarkan hasil Standar Penetration Test (SPT),
diketahui bahwa gedung dibangun di atas tanah dengan
kondisi sedang. Dalam perhitungan termasuk Sistem Rangka
Pemikul Momen Menengah (SRPMM) dan dalam
perhitungan beban gempa rencana menggunakan metode
respons spectrum.
Peraturan yang digunakan adalah standar desain yang
berlaku di Indonesia yaitu SNI 03-1726-2012, SNI 03-1729-
2002, SNI 03-2847-2002, SNI 03-2847-2013,PPIUG 1983
dan PBBI 1971. Kota Surabaya termasuk dalam zona gempa
sedang. Sehingga didapatkan hasil perhitungan analisis
strukturnya dengan periode gempa 1000 tahun menggunakan
metode Sistem Rangka Pemikul Momen Menengah
(SRPMM).
Struktur utama pada gedung (balok,sloof dan kolom)
dan komponen sekunder (pelat dan tangga) menggunakan
struktur beton bertulang. Struktur bawah (poer dan sloof) dari
bahan beton bertulang. Untuk pondasi menggunakan tiang
pancang. Hasil dari perhitungan ini adalah bangunan tersebut
mampu menahan gaya gempa yang terjadi. Dari perhitungan yang dikerjakan , diperoleh hasil struktru atap baja
menggunakna WF 300.200.9.14 dengan kolom pendek pipa
12.75 inch dan batang spaceframe diameter 3.5 inch hingga 4
inch. Struktur atas yang terdiri dari tebal pelat lantai dan atap
12 cm; dimensi kolom 60x60 cm; dimensi Balok induk 55/90;
dimensi balok anak 40/60; tangga denga lebar injakan 30 cm
dan tinggi injakan 15 cm; sedangkan struktur bawah dipakai
tiang pancang d45 cm dengan kedalaman 12 m.
=================================================================================================
Anggrek’s Hotel Surabaya is located at Gubeng street
Surabaya. Based on the results of Standard Penetration Test
(SPT), it’s known that the building was built on land with
middle conditions . In this calculation included in
Intermediate Momen Resisting Frame System (SRPMM) and
in the calculation of earthquake loads is using respons
spectrum.
The used regulations is applicable design standards in
Indonesia, SNI 03-1726-2012, SNI 03-1729-2002, SNI 03-
2847-2002, SNI 03-2847-2013,PPIUG 1983 dan PBBI 1971 .
Surabaya included in the midlle zone of earthquake. Therefore
the structure analysis is used method with 1000 years
eartquake’s periods.
The main structure of the building (beams, columns and
Sloof) and secondary components (plates and stairs) using
reinforced concrete structures The bottom structure (poer and
sloof) of reinforced concrete materials. For the foundation is
using piles. The result of this calculation is that the building is able to withstand the force of the earthquake. From
calculation wich have been done, the calculation in that steel
top structure consist of beam steel WF 300.200.9.14; coloumn
pipe 12,75 inch; spaceframe 3,5 inch until 4 inch. The top
structure consist of thick floor plate 12 cm; coloumn
dimension 60 cm x 60cm; beam dimension 55 cm x 90 cm;
staircase with 30 cm of ontrade width and 15 cm of uprade
height; while on bottom structure got d 45 cm og piling
dimension with 12 cm of depth.
Item Type: | Thesis (Diploma) |
---|---|
Additional Information: | RSS 690.85 Rah p |
Uncontrolled Keywords: | Gedung bertingkat, SRPMM, Respon spektrum, SNI, SPT, PPIUG, PBBI |
Subjects: | T Technology > TH Building construction |
Divisions: | Faculty of Civil Engineering and Planning > Civil Engineering > 22401-(D3) Diploma 3 |
Depositing User: | - Taufiq Rahmanu |
Date Deposited: | 13 Nov 2019 07:42 |
Last Modified: | 13 Nov 2019 07:42 |
URI: | http://repository.its.ac.id/id/eprint/71758 |
Actions (login required)
View Item |