Modifikasi Perencanaan Struktur Social Security Tower Di Jakarta Dengan Menggunakan Sistem Struktur Steel Plate Shear Wall (Spsw)

Basysyar, Muhammad (2020) Modifikasi Perencanaan Struktur Social Security Tower Di Jakarta Dengan Menggunakan Sistem Struktur Steel Plate Shear Wall (Spsw). Other thesis, Institut Teknologi Sepuluh Nopember.

[thumbnail of 03111540000040_Undergraduate_Thesis.pdf]
Preview
Text
03111540000040_Undergraduate_Thesis.pdf

Download (20MB) | Preview

Abstract

Pertumbuhan penduduk di Indonesia yang semakin lama semakin meningkat, menyebabkan kebutuhan infrastruktur bertambah secara signifikan terutama untuk gedung perkantoran dan tempat tinggal. Hal ini terutama sangat dirasakan dikota-kota besar. Dalam perencanaan suatu bangunan gedung bertingkat haruslah didesain tahan terhadap gempa dikarenakan ancaman gempa bumi yang cukup tinggi diwilayah Indonesia sehingga kemungkinan korban jiwa bisa diminimalisir. Selain bangunan yang terbuat dari struktur beton, struktur baja bisa menjadi alternatif dalam perencanaan Gedung. Baja memiliki sifat daktail, dimana mampu berdeformasi tanpa langsung runtuh yang dapat dimanfaatkan pada saat struktur memikul beban akibat gempa.
Steel Plate Shear Wall (SPSW) merupakan salah satu sistem penahan beban lateral yang terdiri dari plat baja vertikal padat yang menghubungkan balok dan kolom disekitarnya dan terpasang sepanjang ketinggian struktur sehingga membentuk sebuah dinding penopang. Penggunaan SPSW dapat menghasilkan kekakuan struktur yang besar dan perilaku daktail pada struktur, selain itu SPSW memiliki tingkat penyerapan energi yang besar. Oleh karena itu, menurut sifat sifat yang dimiliki SPSW ini sangat cocok dimanfaatkan untuk mengurangi beban gempa yang terjadi. Dalam tugas akhir ini, perhitungan struktur Gedung dengan sistem SPSW ini mengacu pada Standar Perencanaan Ketahanan Gempa Untuk Struktur Bangunan Gedung SNI 03-1726-2018, Tata Cara Perencanaan Struktur Baja Untuk Struktur Bangunan Gedung SNI 03-1729-2015, dan beban minimum untuk perencanaan bangunan gedung dan struktur lain SNI 1727-2013. Dan dalam menganalisis strukturnya ditinjau dengan pengaruh beban gempa dinamik dengan menggunakan program bantu ETABS. Dari hasil analisa dan diperhitungan yang telah dilakukan, didapatkan : Tebal pelat lantai dan atap dengan menggunakan bondex adalah 9 cm dan 10 cm, dimensi balok induk melintang dan memanjang WF 800x300x14x22, ketebalan SPSW dipakai 5 mm, dimensi HBE WF 800x300x14x22, dimensi VBE CFT 800x800x28x28, dimensi kolom lantai 1-5 CFT 800x800x28x28, dimensi kolom lantai 6-atap CFT 700x700x28x28, dan dimensi kolom beton 1100x1100. Perencanaan bangunan bawah menggunakan dinding penahan dengan tipe cantilever wall dan pondasi menggunakan tiang pancang beton diameter 60 cm dengan kedalaman 24 meter dan dimensi sloof 45/65 cm.
=================================================================================================================================
The growth population in Indonesia is increasing rapidly making the need for infrastucture increased significanty. especially for the office building and residence. This case especially true in big cities. For the planning of a multi-storey building should be designed to withstand earthquakes due to the high earthquake threats in Indonesia so that the risk of casualties when an earthquake occurs can be minimized. Besides building who made of concrete structure, steel structures can be an alternative in building planning. Steel has ductile properties, which are able to deform without collapsing directly. which can be utilized when the structure is overburdened caused by earthquake. Steel Plate Shear Wall (SPSW) is one of the lateral load-bearing systems consisting of solid vertical steel plates connecting adjacent beams and columns and mounted along the height of the structure to form a supporting wall. The use of SPSW can result in large structural stiffness and ductile behavior on the structure, besides SPSW has a large energy absorption rate. These properties are very suitable to be used to reduce the earthquake load that occurred. In this final project, design modification of building structure using SPSW system is referring to Earthquake Resistance Planning Standards For Building Structure SNI 03-1726-2018, Procedure Planning Steel Structure For Building Structure SNI 03-1729- 2015, and the minimum load for the planning of buildings and structures Other SNI 1727-2013, And in analyzing the structure using the asset program ETABS. From the analyzing and calculating, that has been done, obtained : The thickness of the floor and roof plate using bondex is 9 cm and 10 cm, the dimensions of the main beam is WF 800x300x14x22, The thickness of SPSW is 5 mm, HBE dimensions WF 800x300x14x22, VBE dimensions CFT 800x800x28x28, the dimensions of the 1-5th floor is 800x800x28x28 columns, the dimensions of the 6 th-roofed floor is 700x700x28x28 columns, and the dimensions of the concrete column is 1100x1100. Basement and foundation planning consists of retaining wall using cantilever wall type and foundation using 60 cm diameter concrete piling piles with a depth of 24 meters and dimensions of sloof is 45/65 cm.

Item Type: Thesis (Other)
Additional Information: RSS 624.111 Bas m-1 2020
Uncontrolled Keywords: Steel Plate Shear Wall, Gempa, Daktilitas, Struktur Baja
Subjects: T Technology > TH Building construction > TH1095 Earthquakes and building
Divisions: Faculty of Civil, Planning, and Geo Engineering (CIVPLAN) > Civil Engineering > 22201-(S1) Undergraduate Thesis
Depositing User: Muhammad Basysyar
Date Deposited: 26 Apr 2024 08:15
Last Modified: 26 Apr 2024 08:15
URI: http://repository.its.ac.id/id/eprint/73531