Analisa Penyebab Kerusakan Pada Boiler Dengan Metode Failure Mode Effect Analysis. Studi Kasus: Pembangkit Listrik Tenaga Uap

Anggy, Iswanto (2020) Analisa Penyebab Kerusakan Pada Boiler Dengan Metode Failure Mode Effect Analysis. Studi Kasus: Pembangkit Listrik Tenaga Uap. Masters thesis, Institut Teknologi Sepuluh Nopember.

[thumbnail of Anggy Iswanto.pdf]
Preview
Text
Anggy Iswanto.pdf

Download (670kB) | Preview

Abstract

Perawatan didalam suatu industri perlu untuk diperhatikan dalam upaya menjaga agar kondisi fasilitas produksi dapat tetap beroperasi dengan baik. Pembangkit Listrik Tenaga Uap (PLTU) XYZ merupakan salah satu pembangkit swasta (Independent Power Producer/IPP), PLTU XYZ menjual listrik kepada Perusahaan Listrik Negara (PLN) sebagai konsumen utama. Permasalahan yang dihadapi oleh PLTU XYZ yang saat ini sering terjadi adalah unplanned downtime pada Boiler sehingga mengakibatkan nilai availability mengalami penurunan. Dari data unplanned downtime selama tahun 2019 menunjukkan bahwa sering dilakukan proses pemberhentian pada boiler dengan total waktu selama 39 hari. Untuk itu diperlukan upaya analisa penyebab kerusakan untuk mengurangi unplanned downtime pada boiler dengan metode Failure Mode Effect Analysis (FMEA). Sebelum dilakukan proses analisa, langkah awal yang perlu dilakukan adalah indentifikasi gejala untuk mengetahui akar penyebab masalah menggunakan metode Fault Tree Analysis (FTA). Setelah diketahui akar penyebab masalah, selanjutnya dilakukan proses analisa dengan diagram pareto untuk mengetahui masalah yang paling sering terjadi. Metode FMEA digunakan untuk menentukan prioritas kerusakan pada boiler dengan mengukur nilai dari Risk Priority Number (RPN) dengan cara melakukan ranking kriteria yaitu: Severity (S), Occurrence (O), Detection (D). Dari hasil analisa dan pembahasan didapakan tiga kerusakan kritis dengan nilai RPN tube leak sebesar 405, slagging dan fouling sebesar 270, dan Submerged Scrapper Chain Conveyor (SSCC) sebesar 40. Usulan prioritas perbaikan adalah tube leak dengan melakukan tindakan tube coating dan water canon. =================================================================================================================================
Maintenance in an industry needs to be considered in an effort to maintain the condition of production facilities in order to operate properly. The XYZ Steam Power Plant (PLTU) is one of the Independent Power Producers (IPP), XYZ PLTU sells electricity to the State Electricity Company (PLN) as the main consumer. The problem faced by the XYZ PLTU which often happens now is unplanned downtime in Boilers resulting in decreased availability. Unplanned downtime data for 2019 shows that the boiler is often stopped by a total of 39 days. For this reason, analysis cause of failure are needed to reduce unplanned downtime in boilers using the Failure Mode Effect Analysis (FMEA) method. Before the analysis cause of failure, the first step that needs to be done is to identify the symptoms to find out the root cause of the problem using the Fault Tree Analysis (FTA) method. After knowing the root cause of the problem, then the analysis process is carried out with a Pareto diagram to find out the most common problems. The FMEA method is used to determine the priority of failure on boiler by measuring the value of the Risk Priority Number (RPN) by ranking criteria, namely: Severity (S), Occurrence (O), Detection (D). From the results of the analysis and discussion there were three critical failure with a tube leak RPN of 405, slagging and fouling of 270, and submerged scrapper chain conveyor (SSCC) of 40. The Proposed priority of repairs is tube leak by carrying out the action of tube coating and water canon.

Item Type: Thesis (Masters)
Additional Information: RTMT 620.004 6 Isw a-1 2020
Uncontrolled Keywords: Boiler, Unplanned Downtime, Failure Mode Effect Analysis
Subjects: T Technology > TA Engineering (General). Civil engineering (General) > TA169.5 Failure analysis
Divisions: Interdisciplinary School of Management and Technology (SIMT) > 61101-Master of Technology Management (MMT)
Depositing User: Anggy Iswanto
Date Deposited: 06 Jun 2024 07:28
Last Modified: 06 Jun 2024 07:28
URI: http://repository.its.ac.id/id/eprint/74215