Bernandes, Andre (2016) Desain Modifikasi Struktur Apartemen “The Aspen @ Admiralty” Menggunakan Metode Flat Slab Andre Bernandes. Undergraduate thesis, Institut Teknologi Sepuluh Nopember Surabaya.
Preview |
Text
3112100089-Undergraduate_Thesis.pdf - Published Version Download (6MB) | Preview |
Abstract
Gedung Apartemen “The Aspen @Admiralty”
direncanakan dibangun pada Zona Gempa menengah ( SNI 03-
1726-2002 ) terletak di Jalan RS Fatmawati,Cilandak,Jakarta
Selatan. Desain sesungguhnya dari apartemen ini adalah beton
bertulang. Dalam tugas akhir ini, dilakukan beberapa modifikasi
perencanaan. Perencanaan menggunakan strutur flat slab
dengan dikombinasikan dengan shear wall yang berfungsi
sebagai struktur penahan gaya lateral. Struktur atas yang lainnya
pada gedung ini meliputi kolom,balok tepi,dan drop panel,
sedangkan struktur bawah menggunakan pondasi tiang pancang
serta T-beam sebagai penghubung.
Struktur flat slab digunakan secara luas pada bangunan
gedung karena beberapa kelebihan dalam aspek struktural
maupun arsitektural.Lantai yang didapatkan lebih luas dan
tinggi, tidak perlu finishing dengan plafond,hemat biaya proyek
karena mengurangi pemakaian beton dan bekisting untuk elemen
balok. Disamping kelebihan tersebut, terdapat kelemahan yang
mengakibatkan perilaku yang tidak ideal pada saat struktur
menerima kombinasi beban gravitasi dan lateral. Kelemahan
tersebut terdapat pada hubungan pelat-kolom, dimana tegangan
lentur dan geser terakumulasi sebagai resultan dari beban
gravitasi dan momen tak imbang yang disebabkan oleh beban
lateral seperti halnya gempa. Namun, kelemahan tersebut dapat
ditanggulangi dengan adanya drop panel. Drop panel merupakan
penebalan pelat di daerah kolom sebagai kekuatan geser penahan
gaya geser pons yang cukup besar pada daerah hubungan pelatkolom.
Di daerah gempa potensial seperti halnya sebagian besar
wilayah Indonesia, perilaku yang tidak ideal pada saat struktur
v
menerima kombinasi beban gravitasi dan lateral dapat ditahan
oleh dinding geser (Shear Wall).
Dalam tugas akhir ini, secara keseluruhan direncanakan
dengan Sistem Rangka Gedung (SRG) karena dikombinasikan
dengan SPBL yaitu dinding structural. Sehubungan dengan
itu,SNI 03-1726-2012 membatasi penggunaan struktur flat slab
lebih spesifik, yaitu struktur diklasifikasikan sebagai SRPMM
(Sistem Rangka Pemikul Momen Menengah) dan jika
digunakan sebagai sistem tunggal, maka kategori desain
gempa yang sesuai adalah B dan C tidak dibatasi dan D, E dan F
tidak diijinkan. Di samping itu, jika digunakan dengan dinding
geser khusus, maka kategori desain gempa yang sesuai adalah B
dan C tidak dibatasi, D dibatasi dengan tinggi maksimum 48m,
dan E dan F dibatasi tinggi maksimum 30m
============================================================================= “The Aspen @Admiralty “Apartment Building will be
built in medium Earthquake Zones (SNI 03-1726-2002) is located
in Jalan RS Fatmawati, Cilandak, South Jakarta. The actual
design of the apartments are of reinforced concrete. In this final
project, will do some modification design. The modification
design using flat slab structure in combination with shear wall
that serves as a lateral force resisting structure. The structure
above the other in the building include columns,edge beams and
drop panels, while the bottom structure using pile foundation and
T-beam as a liaison.
Flat slab structure is widely used in buildings because
some advantages in the aspects of structural and arsitektural.
Floors were obtained broader and higher, finishing the ceiling
is not necessary, cost-effective projects for reducing the use of
concrete and formwork for beam elements. Besides these
advantages, there are drawbacks that resulted in behavior
which is not ideal when the structure receives a combination of
gravity and lateral loads. The weaknesses found in relation
plate-columns, where the bending stress and shear accumulate as
resultant of gravity and moment loads do not draw caused by
lateral loads such as earthquake. However, this weakness can be
overcome by the drop panel. Drop panel is a thickening of the
plate in the column as the shear strength of the shear force
resisting puncher sizeable on the area plate-column relationship.
In the area of potential earthquake as well as most parts of
Indonesia, the behavior is not ideal when the structure receives a
combination of gravity and lateral loads can be retained by a
sliding wall (Shear Wall).In this thesis, the overall planned
Building Frame System (SRG) for SPBL is combined with
vii
structural walls. In connection with that, SNI 03-1726-2012 limit
the use of more specific flat slab structure, namely the structure is
classified as SRPMM (Intermediate Moment Frame System
bearers), and when used as a single system, then the appropriate
seismic design category B and C is not limited and D, E and F
are not permitted. In addition, when used with a special sliding
walls, then the appropriate seismic design category B and C is
not restricted, D restricted to a maximum height of 48m, and E
and F are restricted maximum height of 30m
Item Type: | Thesis (Undergraduate) |
---|---|
Additional Information: | RSS 690.831 4 Ber d |
Uncontrolled Keywords: | Flat Slab, Shear Wall, Drop Panel |
Subjects: | N Fine Arts > NA Architecture > NA7115 Domestic architecture. Houses. Dwellings |
Divisions: | Faculty of Civil Engineering and Planning > Civil Engineering > 22201-(S1) Undergraduate Thesis |
Depositing User: | EKO BUDI RAHARJO |
Date Deposited: | 10 Feb 2020 03:08 |
Last Modified: | 10 Feb 2020 03:08 |
URI: | http://repository.its.ac.id/id/eprint/74769 |
Actions (login required)
View Item |