Studi Eksperimen Perbandingan Unjuk Kerja Pompa Shimizu Ps-116 Bit Standar Dan Modifikasi Dengan Metode Pengujian Instalasi

Sakhty, Fhabry Refha (2016) Studi Eksperimen Perbandingan Unjuk Kerja Pompa Shimizu Ps-116 Bit Standar Dan Modifikasi Dengan Metode Pengujian Instalasi. Diploma thesis, Institut Teknologi Sepuluh Nopember Surabaya.

[thumbnail of 2113030009-Non_Degree.pdf]
Preview
Text
2113030009-Non_Degree.pdf - Published Version

Download (2MB) | Preview

Abstract

Di kalangan masyarakat Rejotangen kabupaten
Tulungagung belakangan ini, sering dijumpai modifikasi pada
pompa standar dengan jalan mengubah impeler yang semula
berjenis Radial menjadi Backward, disertai pula dengan
perubahan pada volute chambernya. Modifikasi ini bertujuan
untuk meningkatkan unjuk kerja pompa standar. Namun demikian
nilai unjuk kerja sebenarnya dari pompa modifikasi ini belum
diketahui.
Pada tugas akhir ini dilakukan perhitungan berdasarkan
pengujian instalasi dengan data dari hasil pengukuran.
Perhitungan dilakukan pada pompa SHIMIZU PS-116 BIT
standar dan modifikasi tanpa perubahan daya motor
penggeraknya, dari hasil perhitungan yang didapat digunakan
untuk membandingkan nilai unjuk kerjanya secara aktual.
Pada perhitungan yang telah dilakukan didapat bahwa
pada kondisi fully open nilai unjuk kerja pompa modifikasi lebih
unggul dari pada pompa standar. Terbukti dengan nilai Head
efektif pompa modifikasi memcapai 6.01262 m sedangkan pompa
standar 5.00346 m, diikuti dengan nilai unjuk kerja yang lainya
kapasitas pompa modifikasi memncapai 0.000889 m3/s sedangkan
pompa standar 0.000389 m3/s, nilai WHP dan Nshaft pompa
modifikasi mencapai 52.20463 watt dan 267.52 watt secara
berurutan sedangkan untuk pompa standar 19.00614 watt dan
258.72 watt. Nilai terakhir adalah efisiensi, untuk pompa
modifikasi mencapai 19.51429 % jauh dahi pompa standar yang
hanya mencapai 7.346221 %
============================================================================================
In recent times, apply modification to the default pump
becomes common among the people of Rejotangen, Tulungagung
regency. They change pump impeller that was oroginally Radial
type to be Backward type accompanied with the changes on its
volute chamber. This modification aims to improve pump
performance value. But however, the value of the actual
performance of this pump modification is not yet known.
In this final project was performed calculations based on
testing the installation with data from measurement results. The
calculation will be done on the pump SHIMIZU PS-116BIT
standard and modification without change of its motor power.
From the calculation result is used to compare the value of the
actual work performance.
On the calculation that had been done was obtained on the
fully open condition of the modification pump performance rating
is higher than the standard pump. With proven value the effective
Head of modification pump reaches 6.01262 m whereas the
standard pump 5.00346 m, followed by the value of the other
performance modifications to the pump's capacity reached
0.000889 m3/s whereas the standard pump 0.000389 m3/s, a value
Nshaft and WHP pump modification reaches 52.20463 watt and
267.52 Watts respectively whereas for standard pump 19.00614
Watts and 258.72 Watts. The last value is the efficiency, to pump
modification reaches 19.51429% away from the standard pump
only reached 7.346221%

Item Type: Thesis (Diploma)
Additional Information: RSM 621.67 Sak s
Uncontrolled Keywords: Head, Kapasitas, WHP, Nshaft, Efisiensi
Subjects: T Technology > TJ Mechanical engineering and machinery > TJ919 Centrifugal pumps--Design and construction.
Divisions: Faculty of Industrial Technology > Mechanical Engineering > 21401-(D3) Diploma 3
Depositing User: EKO BUDI RAHARJO
Date Deposited: 22 Jul 2020 00:54
Last Modified: 22 Jul 2020 00:55
URI: http://repository.its.ac.id/id/eprint/76445

Actions (login required)

View Item View Item