Pratiwi, Rizky Kurniasari Kusuma (2016) Rancang Bangun Sistem Pengendalian Pressure Pada Tabung Penyimpanan Dari Hasil Pencampuran Gas Hidrogen Dengan Gas Sebagai Sumber Energi Genset. Diploma thesis, Institut Teknologi Sepuluh Nopember.
Preview |
Text
2413031058-Non_Degree.pdf - Accepted Version Download (2MB) | Preview |
Abstract
Sistem pengendalian pressure pada tabung penyimpanan dari hasil pemcampuran gas hidrogen dengan gas merupakan sistem yang digunakan untuk mengendalikan tekanan pada tabung penyimpanan agar proses stabil dengan menggunakan dua buah jenis sensor tekanan MPX5700AP, empat buah aktuator berupa solenoid valve serta controller-nya menggunakan microcontroller ATmega8535. Pada tugas akhir ini menggunakan prinsip kerja redundant, yaitu apabila gas yang masuk melalui tabung penyimpanan maka sensor MPX5700AP akan mengirimkan sinyal ke microcontroller ATmega8535 hingga mencapai set point sebesar 15 Psi. Jika data yang masuk ke microcontroller ATmega8535 kurang dari batas set point minimum sebesar 10 Psi, maka dari microcontroller ATmega8535 akan memerintahkan solenoid valve 1 untuk menyala (on) sampai mencapai menuju set point 15 Psi yang kemudian solenoid valve 1 mati (off) dan akan mengaktifkan solenoid valve 2 untuk bekerja membuang gas pada genset. Saat proses pembuangan gas, pada tabung penyimpanan 2 akan mengaktifkan solenoid valve 3 untuk menerima gas yang masuk sampai mencapai set point 15 Psi dan kemudian solenoid valve 3 mati (off) dan akan mengaktifkan solenoid valve 4 untuk bekerja membuang gas pada genset. Respon kontrol sistem ini membutuhkan waktu untuk mencapai set point sebesar 42.6 detik.
=======================================================================================================Pressure control system on the storage tube of the results of mixing hydrogen gas with gas is a system used to control the pressure in the storage tube so that a stable process by using two types of pressure sensors MPX5700AP, four actuators such as solenoid valve and using a microcontroller ATmega8535. In this final project work using the principle of redundant, that is when gas entering through the storage tube MPX5700AP sensor will send a signal to the microcontroller ATmega8535 to reach set point at 15 Psi. If the incoming data to the microcontroller ATmega8535 less than the limit set point minimum of 10 Psi, then of microcontroller ATmega8535 will command solenoid valve 1 to turn (on) until it reaches to the set point 15 Psi then solenoid valve 1 off (off) and will enable solenoid valve 2 for working exhausted of gas in the generator. When the exhaust gas, the storage tubes 2 will activate the solenoid valve 3 for receiving the incoming gas to reach set point 15 Psi then solenoid valve 3 off (off) and will activate the solenoid valve 4 to work throwing gas in the generator. control the response of system takes time to reach the set point of 42.6 seconds. Keywords : Control, Pressure,
Item Type: | Thesis (Diploma) |
---|---|
Additional Information: | RSF 629.895 Pra r 3100016067907 |
Uncontrolled Keywords: | Pengendalian; tekanan; MPX5700AP; solenoid valvew ATmega8535; set point |
Subjects: | T Technology > TK Electrical engineering. Electronics Nuclear engineering > TK3070 Automatic control |
Divisions: | Faculty of Industrial Technology > Physics Engineering > (D3) Diploma 3 |
Depositing User: | Yeni Anita Gonti |
Date Deposited: | 22 Jul 2020 08:01 |
Last Modified: | 22 Jul 2020 08:01 |
URI: | http://repository.its.ac.id/id/eprint/76456 |
Actions (login required)
View Item |