Zuhair, Hilmy Yafi' (2020) Pengaruh Jarak X-Ray Image Intensifier Dengan Meja Pasien Terhadap Sebaran Dosis Radiasi Pada Ruang Cath Lab Rumah Sakit. Undergraduate thesis, Institut Teknologi Sepuluh Nopember.
Preview |
Text
01111640000010-Undergraduate_Thesis.pdf Download (1MB) | Preview |
Abstract
Penelitian ini bertujuan untuk mengetahui pengaruh jarak dilakukan untuk mengetahui pengaruh jarak x-Ray image intensifier dengan meja pasien terhadap sebaran dosis radiasi pada ruang cath lab Rumah Sakit Universitas Airlangga. Penelitian ini dilakukan dengan mengatur variasi ketinggian Pengukuran dilakukan dengan menggunakan variasi X-ray image intensifier terhadap X-ray tube, sedangkan ketinggian meja pasien ditetapkan pada satu nilai saja, sehingga selisih ketinggian antara X-ray image intensifier dengan meja pasien didapat. Kemudian, titik ukur ditetapkan dan dilakukan penyinaran selama tiga detik dan dibiarkan hingga dua puluh detik ke depan. Hasil pengukuran yang didapat adalah laju dosis dalam µSv/h, kemudian dikonversi ke µSv/s. Laju dosis yang didapat pada setiap titik kemudian ditentukan besaran akumulasinya dengan metode aturan trapezoid. Pada penelitian ini didapatkan bahwa jarak antara X-ray image intensifier dengan meja pasien yang lebih jauh, dosis radiasi akumulasi yang dihasilkan lebih kecil.
========================================================================================================================
This study was conducted to determine the effect of the distance between X-ray image intensifier and patient table on radiation dose distribution in Cath Lab at Airlangga University Hospital. This study is done by adjusting the position of an X-ray image intensifier and the patient table that had been set in a specific position. From that, the value of difference can both be known. The plot measurements are then determined and irradiated each of the plots for three seconds, and measurement is done up to twenty seconds. The measurement that taken is dose rate (µSv/h), and then, they are converted to µSv/s. Next, the dose accumulation on each plot is processed by trapezoid rule. The result of this study is the smaller value of dose accumulate on each plot for the further distance between X-ray image intensifier and patient table.
Item Type: | Thesis (Undergraduate) |
---|---|
Uncontrolled Keywords: | dosis, radiasi, X-ray image intensifier, dose, radiation, X-ray image intensifier |
Subjects: | Q Science > QC Physics > QC795.5 Radioactivity and radioactive Instruments and apparatus (General) |
Divisions: | Faculty of Science and Data Analytics (SCIENTICS) > Physics > 45201-(S1) Undergraduate Thesis |
Depositing User: | Hilmy Yafi' Zuhair |
Date Deposited: | 06 Aug 2020 03:26 |
Last Modified: | 15 May 2023 14:41 |
URI: | http://repository.its.ac.id/id/eprint/76543 |
Actions (login required)
View Item |