Analisis Reliability Dan Safety Integrity Level Pada Sistem CO Shift Convertion Di PT. Petrokimia Gresik

Marzuki, Esther Luciane (2016) Analisis Reliability Dan Safety Integrity Level Pada Sistem CO Shift Convertion Di PT. Petrokimia Gresik. Undergraduate thesis, Institut Teknologi Sepuluh Nopember.

[thumbnail of 2412100073-Undergraduate_Thesis.pdf]
Preview
Text
2412100073-Undergraduate_Thesis.pdf - Accepted Version

Download (2MB) | Preview

Abstract

CO Shift Convertion adalah sebuah sistem yang digunakan dalam
proses pembuatan amonia yang berfungsi untuk mengubah gas karbon
monoksida (CO) keluaran dari steam reformer menjadi gas karbon
dioksida (CO2) dan gas hidrogen (H2). Sistem ini sudah beroperasi sejak
tahun 1994, sehingga performansi setiap komponennya sudah tidak
sama sejak awal beroperasi. Apabila terdapat kerusakan pada
komponen-komponen sistem maka mengakibatkan kerja sistem CO Shift
Convertion ini kurang optimal sehingga berdampak pada beban kerja
yang meningkat untuk sistem selanjutnya. Oleh karena itu, dalam tugas
akhir ini dilakukan analisa reliability dan safety integrity level pada
sistem CO Shift Convetion ini. Analisa reliability dilakukkan dengan
metode kuantitatif dan kualitatif. Analisa kuantitatif dilakukan dengan
metode RBD untuk mengetahui reliability dan availability sistem.
Analisa kualitatif dilakukan dengan menggunakan metode FTA dan
FMEA untuk mengetahui jenis kegagalan, basic event yang dapat
menyebabkan sistem ini gagal, efek yang ditimbulkan, dan langkah
penanganan masalah yang diambil. Sistem CO Shift Convertion
mencapai nilai reliability 0,6 pada 540 jam, dan memiliki ketersediaan
93%. Nilai reliability pada 8760 jam adalah 0,3. Hasil menggunakan
FTA, nilai reliability CO Shift Convertion pada 8760 jam atau 1 tahun
adalah 0,1. CO Shift Convertion memiliki tingkatan SIL 0 dengan PFD
0.709 pada 720 jam 79.229 pada 4320 jam, dan 34.754 pada 8760
==================================================================================================================
CO Shift Conversion is a system used in the manufacture of
ammonia gas which serves to convert carbon monoxide (CO) output of a
steam reformer to carbon dioxide (CO2) and hydrogen gas (H2). This
system has been in operation since 1994, so that the performance of
each component is not the same since the beginning of operation. If
there is damage to the system components, then the resulting working
CO Shift Conversion system is less than optimal so the impact on an
increased workload for the next system. Therefore, in this research,
reliability and safety integrity level analysis at CO Shift Convertion
system has been conducted with qualitative and with quantitative and
qualitative method . The quantitative analysis was conducted by RBD to
determine the reliability and availability of the system. Qualitative
analysis performed using the FTA and FMEA to know failure mode, the
basic event that could cause the system to fail, the effect for the system,
and action required to handle the failure . CO Shift Conversion System
reached a value of 0.6 on a 540-hour reliability, and has a 93%
availability. Rated reliability at 8760 hours was 0.3. Results using the
FTA, the value of reliability CO Shift Conversion at 8760 hours or 1
year is 0.1. CO Shift Conversion has a SIL level 0 with PFD 0.709 at
729 hours, 79.229 at 4320 hours, and 34.754 in 8760 hours

Item Type: Thesis (Undergraduate)
Additional Information: RSF 620.86 Mar a
Uncontrolled Keywords: Reliability, Safety integrity level, CO shift convertion
Subjects: T Technology > TS Manufactures > TS174 Maintainability (Engineering) . Reliability (Engineering)
Divisions: Faculty of Industrial Technology > Physics Engineering > 30201-(S1) Undergraduate Thesis
Depositing User: ansi aflacha
Date Deposited: 29 Jul 2020 03:40
Last Modified: 29 Jul 2020 03:40
URI: http://repository.its.ac.id/id/eprint/76637

Actions (login required)

View Item View Item