Abstract

Orifice plate merupakan suatu alat yang sangat penting dalam dunia industri, dimana penggunaan orifice ini yaitu untuk menciptakan perbedaan tekanan antara sisi upstream dan sisi downstream yang nantinya akan dihasilkan nilai dari pressure suatu fluida yang masuk. Orifice concentric umumnya mempunyai kelemahan yaitu rugi tekanan yang akan berakibat pada pressure loss. Pressure loss adalah selisih tekanan yang masuk yang masuk pada sisi upstream dengan tekanan setelah melewati sisi downstream pada orifice tersebut dan biasanya ditunjukan melalui perbedaan tekanan yang terjadi antara upstream dan downstream. Untuk mengetahui karakteristik dari orifice maka perlu dilakukan kalibrasi. Pada penelitian kali ini telah dibuat sebuah rancang bangun sistem pengukuran dan monitoring laju aliran pada orifice plate dengan sensor MPX2010DP yang diintegrasikan dengan arduino uno sebagai mikrokontrollernya dan visual basic 2013 sebagai interface dari monitoring. Alat ukur dari rancang bangun orifice plate mempunya CV sebesar 17,536x, dimana setiap alat ukur mempunyai nilai yang berbeda-beda. Berdasarkan hasil pengujian alat yang telah dilakukan didapatkan nilai ketidakpastian ±0,0553 dengan tingkat kepercayaan 95%. Sedangkan nilai keakurasiannya mencapai 85,43% dengan error 0,015
=============================================================================================
Orifice plate is a very important tool in the industry, where the use of this orifice is to create a pressure difference between the upstream and downstream sides of which it will be generated value from the pressure of a fluid entry. Generally, concentric orifice has the disadvantage that the pressure drop will result in pressure loss. Pressure loss is the difference in pressure of the incoming entries on the upstream side to the downstream side of the pressure after passing in the orifice and it usually indicated by the pressure difference between the upstream and downstream. To know the characteristics of the orifice is necessary to do the calibration. In the current study it has been made a plan to build a system of measurement and monitoring the flow rate orifice plate with MPX2010DP sensor integrated with a microcontroller arduino uno and Visual Basic 2013 as the interface of monitoring. Measuring instrument has an orifice plate CV of 17,536x, where each measuring instrument has different value. Based on the results of testing tools that have to be got value uncertainty ± 0.0553 with a 95% confidence level. While the value Accuracy reached 85.43% with an error of 0.015

Item Type: Thesis (Diploma)
Additional Information: RSF 621.391 6 Saa n
Uncontrolled Keywords: Orifice plate, pressure loss, monitoring
Subjects: T Technology > TA Engineering (General). Civil engineering (General) > TA1573 Detectors. Sensors
T Technology > TJ Mechanical engineering and machinery > TJ935 Pipe--Fluid dynamics. Tubes--Fluid dynamics
Divisions: Faculty of Industrial Technology > Physics Engineering > (D3) Diploma 3