Studi Eksperimen Pengaruh Trimming Impeller Terhadap Performa Pompa Sentrifugal Pada Pompa MQC 175 Menggunakan British Standard ISO 9906:1999

Arifullah, Moch. Rifqy (2020) Studi Eksperimen Pengaruh Trimming Impeller Terhadap Performa Pompa Sentrifugal Pada Pompa MQC 175 Menggunakan British Standard ISO 9906:1999. Other thesis, Institut Teknologi Sepuluh Nopember.

[thumbnail of 02111640000006-Undergraduate_Thesis.pdf]
Preview
Text
02111640000006-Undergraduate_Thesis.pdf

Download (3MB) | Preview

Abstract

Pompa adalah mesin yang digunakan untuk memindahkan fluida dari suatu tempat yang rendah ke tempat yang lebih tinggi, atau dari suatu tempat bertekanan rendah ke tempat yang bertekanan lebih tinggi melalui sistem perpipaan. Pompa mengubah energi mekanik dari poros yang menggerakkan sudu-sudu pada impeller pompa menjadi energi kinetik dan tekanan pada fluida. Putaran impeller menyebabkan kondisi vakum pada pusat impeller yang dapat menghisap fluida, kemudian fluida dialirkan melalui sudu – susu yang ada pada impeller. Pada sudu – sudu ini terjadi efek diffusor yang menyebabkan tekanan aliran fluida meningkat. Banyak pompa dengan head besar dipasang pada sistem perpipaan yang membutuhkan head lebih kecil, akibatnya pompa beroperasi pada efisiensi yang rendah. Trimming impeller dilakukan untuk mengurangi head yang dihasilkan oleh pompa dan berpotensi meningkatkan efisiensi pompa untuk sistem perpipaan yang sama.
Eksperimen dilakukan untuk mengevaluasi karakteristik performa pompa terhadap perubahan geometri impeller dan pengaruh terhadap sistem perpipaan. Pompa sentrifugal dalam pengujian ini memiliki impeller tipe backward dengan jumlah sudu enam buah. Impeller di trimming pada diameter terluarnya sebesar 2,71% dalam 10 tahap pemotongan berdasarkan Annex B pada British Standard ISO 9906:1999. Pompa pada pengujian ini tersambung dengan motor MQC 175 yang dirangkai dengan alat pengujian CUSSONS friction loss in pipe apparatus. Penelitian ini melibatkan pengukanan pada tekanan suction (Ps) dan discharge (Pd) pompa, tegangan (V) dan arus listrik (A) yang dibutuhkan oleh pompa, losses yang terjadi pada sistem perpipaan (Hpl) dan kapasitas aliran (Q). Parameter tersebut diukur dengan variasi diameter impeller dan kapasitas aliran dari 0 liter/menit hingga kapasitas maksimal. Pengukuran parameter tersebut menggunakan alat ukur pressure gauge, clamp meter, manometer U dengan fluida ukur air raksa dan rotameter. Hasil yang dicapai pada penelitian ini adalah grafik head pompa (Hp), grafik efisiensi (ηp), dan grafik head pipeline (Hpl) terhadap kapasitas aliran (Q) dengan variasi diameter impeller.
Dari penelitian yang telah dilakukan, dapat disimpulkan nilai head turun seiring dengan pengurangan diameter impeller. Namun untuk nilai efisiensi tidak selalu mengalami penurunan seiring pengurangan diameter impeller, efisiensi tertinggi dimiliki oleh impeller dengan diameter 115 mm. Operating point bergeser ke sebelah kiri seiring penurunan diameter impeller. Impeller yang terpotong melebihi Bristish Standard ISO 9906:1999 memiliki karakteristik head dan efisiensi yang sama dengan impeller lain.
==================================================================================================================
Pump is a machine used to move fluid from a low place to a higher place, or from a lower pressure to a higher pressure place through a piping system. The pump transforms the mechanical energy of the shaft that drives the blades in the pump impeller into kinetic energy and pressure on the fluid. The impeller round causes a vacuum condition at the center of the impeller that can suck fluid, then the fluid is flowing through the blades in the impeller. In the blades had a diffusor effect that causes fluid flow pressure to increase. Many pumps with large heads are installed on a piping system requiring a smaller head, consequently the pump operates at low efficiency. The trimming impeller is done to reduce the head generated by the pump and potentially increase the pump efficiency for the same piping system.
Experiments were conducted to evaluate the performance characteristics of pumps against the impeller geometry changes and influence on the piping system. The centrifugal pumps in this test feature a backward-type impeller with a six-piece blades. The Impeller in trimming at its outer diameter was 2.71% in 10 cutting stages based on Annex B of the British Standard ISO 9906:1999. The pumps on this test are connected with the MQC 175 motor that is assembled with CUSSONS friction loss in pipe apparatus testing equipment. This research involves the strengthening of suction pressure (PS) and discharge (PD) pumps, voltage (V) and electric current (A) required by the pump, the losses that occur in the piping system (HPL) and the flow Capacity (Q). These parameters are measured by variations in the impeller diameter and flow capacity from 0 liters/minute to maximum capacity. Measurement of the parameter using pressure gauge gauge, clamp meter, manometer U with mercury and rotameter measuring fluid. The results achieved in this study are graphs of head pumps (Hp), graph efficiency (ηp), and head pipeline (HPL) graphs of flow Capacity (Q) with varying diameter impeller.
From the research that has been done, can be concluded the head value decreases as the impeller diameter reduction. But for the value of efficiency does not always experience a decrease as the impeller diameter reduction, the highest efficiency is possessed by the impeller with a diameter of 115 mm. The Operating point shifts to the left as the diameter decreases the impeller. The truncated impeller exceeding the Bristish Standard ISO 9906:1999 has the same head and efficiency characteristics as the other impeller.

Item Type: Thesis (Other)
Uncontrolled Keywords: trimming impeller, operating point, best efficiency point
Subjects: T Technology > TJ Mechanical engineering and machinery > TJ919 Centrifugal pumps--Design and construction.
Divisions: Faculty of Industrial Technology and Systems Engineering (INDSYS) > Mechanical Engineering > 21201-(S1) Undergraduate Thesis
Depositing User: Moch. Rifqy Arifullah
Date Deposited: 26 Aug 2020 02:35
Last Modified: 03 Jun 2023 13:51
URI: http://repository.its.ac.id/id/eprint/79481