Pembangunan Hotel Swissbel yang terletak di Jalan
Bintoro Surabaya dengan luas area ± 2400 m2 terletak dekat
dengan pusat kota Surabaya. Dengan adanya pembangunan
Hotel Swissbel ini dapat mengakibatkan meningkatnya limpasan
air. Kondisi tersebut dapat mempengaruhi koefisien pengaliran
air permukaan menjadi semakin besar dari 0,17 yang merupakan
lahan kosong menjadi 0,9 dengan adanya bangunan. Sistem
drainase pada Hotel Swissbel ini memiliki konsep menampung air
hujan yang turun selama mungkin dan mengatur pembuangannya
agar debit air dari area Hotel Swissbel tidak membebani saluran
pembuang Bintoro. Dari hasil analisa dan perhitungan
didapatkan dimensi saluran dalam kawasan hotel yaitu 0,5 m x
0,5 m. Besarnya debit dari kawasan Hotel Swissbel adalah
0,0644 m3
/detik yang kemudian akan ditampung terlebih dahulu
di kolam tampungan serta digunakan pintu air sebagai pelimpah
yang berfungsi untuk melimpahkan kelebihan air dalam kolam
tampung. Untuk menjaga agar debit yang keluar dari area hotel
tidak lebih dari 0,00746 m3

/detik dan juga untuk memenuhi
kriteria zero delta Q, maka dilakukan analisa flood routing.
=============================================================================================================
The construction of Swissbel Hotel that is located at
Jalan Bintoro Surabaya with ± 2400 m2 large area, close to the
city center of Surabaya. The construction of the Swissbel Hotel
may result in increased water runoff volume. This condition can
affect the coefficient of surface water drainage to raise from 0,17
which was a wasteland to 0,9 with the building. The drainage
system at Swissbel Hotel has a concept of harvesting the
rainwater for as long as possible and regulating the disposal, so
that the water debit from Swissbel Hotel will not overload the
drainage of Bintoro. Result of the analysis and calculation shows
that the dimension of drainage in the Hotel area is 0,5 m x 0,5 m
large. The ammount of water debit from Swissbell Hotel area is
0,0644 m3
/secon which then will be stored first in a retarding
basin and the water gate will be used to expel the excess water in
that basin. To keep the water debit coming out of the hotel area to
stay less than 0,00746 m3

/secon and also to meet the criteria of

zero delta Q, a flood routing analysis is carried out.

Item Type: Thesis (Undergraduate)
Additional Information: RSS 627.54 Del p 3100014056218
Uncontrolled Keywords: Hotel Swissbel Bintoro, Sistem Drainase, Saluran Bintoro, Kolam Tampungan, Flood Routing.
Subjects: T Technology > TE Highway engineering. Roads and pavements > TE215 Drainage
Divisions: Faculty of Civil Engineering and Planning > Civil Engineering > 22201-(S1) Undergraduate Thesis
Depositing User: Yeni Anita Gonti
Date Deposited: 09 Oct 2020 04:46
Last Modified: 09 Oct 2020 05:17
URI: http://repository.its.ac.id/id/eprint/82103

Actions (login required)

View Item View Item