Analisa Performansi Kondisi Operasi Triethylene Glycol Plant Di PT. Pertamina Hulu Energi WMO(West Madura Offshore) Gresik

Rachmadi, Randi Brian (2014) Analisa Performansi Kondisi Operasi Triethylene Glycol Plant Di PT. Pertamina Hulu Energi WMO(West Madura Offshore) Gresik. Undergraduate thesis, Institut Teknologi Selupuluh Nopember.

[thumbnail of 2412105024_Undergraduate_Thesis.pdf]
Preview
Text
2412105024_Undergraduate_Thesis.pdf - Accepted Version

Download (1MB) | Preview

Abstract

Plant Triethylene glycol berfungsi sebagai menyerap kadar
air dalam gas yang meregenerasi ulang cairan glycol. Pada
plant triethyaelene glycol terjadi pemanasan untuk
memisahkan chemical lain dengan glycol itu sendiri. Laju
aliran yang masuk dalam heat exchanger tejadi penukaran
enrgi panas dalam pipa shell dan tube. Dilakukan pemodelan
simulasi data desain dengan data aktual bertujuan untuk
menganalisa tingkat efisiensi dari tiap perlatan yang ada untuk
penukaran panas dari tiap fluida. Efisiensi dari heat exchanger
dapat dilakukan dengan membandingkan besarnya nilai laju
perpindahan panas dari bagian shell dan tube. Kinerja heat
exchanger mengalami penurunan berdasarkan nilai U, nilai U
dari Pada heat exchanger E-233 pada data desain bernilai
sebesar 194472 kcal/hr dengan penurunan dari data aktual
yang cukup jauh dengan nilai sebesar 166102,3 kcal/hr. Heat
exchanger E-243 dengan nilai koefisien perpindahan panas
dari data desain sebesar 810095 kcal/hr sedangkan data
koefisien perpindahan panas data aktual sebesar 776750,88
kcal/hr. Heat exchanger E-242 mempunyai nilai koefisien
perpindahan panas sebesar 1443555 kcal/hr dan nilai dari
koefisien perpindahan panas data aktual sebesar 1413782,64
kcal/hr. Dengan nilai laju aliran yang konstan dari tiga heat
exchanger pada proses TEG plant.
============================================================================================================
Triethylene glycol plant serves as a moisture absorbing gas to
regenerate the glycol fluid again. In the case of heating glycol
triethyaelene plant to another chemical separating the glycol itself.
Incoming flow rate in the heat exchanger enrgi heat exchange
occurs in the pipe shell and tube. Performed simulation modeling
design data with actual data aims to analyze the level of efficiency
of each of the existing equipment for heat exchange of each fluid.
The efficiency of the heat exchanger can be done by comparing the
value of the rate of heat transfer from the shell and tube.
Performance of heat exchangers decreased by the value of U, U
values of the heat exchanger E-233 on the design data totaled 194
472 kcal / hr with a decrease of the actual data that is quite far to
the value of 166,102.3 kcal / hr. Heat exchangers E-243 with a heat
transfer coefficient of the design data of 810 095 kcal / hr while the
heat transfer coefficient data for the actual data 776,750.88 kcal /
hr. Heat exchangers E-242 has a value of heat transfer coefficient of
1,443,555 kcal / hr and the value of heat transfer coefficient for the
actual data 1,413,782.64 kcal / hr. With a constant flow rate value
of the three heat exchangers in process plant TEG..

Item Type: Thesis (Undergraduate)
Additional Information: RSF 621.402 5 Rac a 3100014057581
Uncontrolled Keywords: Koefisien Perpindahan Panas , heat exchanger, performansi
Subjects: T Technology > TJ Mechanical engineering and machinery > TJ263 Heat exchangers
Divisions: Faculty of Industrial Technology > Physics Engineering > 30201-(S1) Undergraduate Thesis
Depositing User: Yeni Anita Gonti
Date Deposited: 13 Oct 2020 05:35
Last Modified: 13 Oct 2020 05:35
URI: http://repository.its.ac.id/id/eprint/82121

Actions (login required)

View Item View Item