Evaluasi Dinding Penahan Tanah pada Proyek MTH 27 Office Suites

Yustika, Gheanifa Irma (2021) Evaluasi Dinding Penahan Tanah pada Proyek MTH 27 Office Suites. Undergraduate thesis, Institut Teknologi Sepuluh Nopember.

[thumbnail of 10111910015036-Undergraduate_Thesis.pdf]
Preview
Text
10111910015036-Undergraduate_Thesis.pdf - Accepted Version

Download (19MB) | Preview

Abstract

Basement yang direncanakan pada proyek gedung perkantoran MTH 27 Office Suites terdiri dari 4 lantai. Jenis tanah pada proyek ini pada umumnya adalah clay. Proyek MTH 27 Office Suites terletak di lokasi yang sempit serta dikelilingi oleh bangunan komersial yang lain. Pemilihan dinding penahan tanah yang tepat pada proyek ini adalah jenis dinding penahan tanah tipe diaphragm wall. Monitoring pergerakan lateral dinding dengan inklinometer pada proyek MTH 27 Office Suites dilakukan pada 4 titik. Titik inklinometer I-1 mencapai pergerakan lateral terbesar yaitu 112,4 mm dengan kedalaman 14 m. Besarnya deformasi pada titik I-1 dibandingkan dengan kedalamannya mencapai 0,8%, sedangkan syarat maksimum deformasi adalah 0,5%. Evaluasi lebih lanjut perlu dilakukan untuk menilai stabilitas dinding penahan tanah terhadap beban yang terjadi. Penelitian ini bertujuan untuk mengetahui stabilitas tanah dasar galian dinding, perbandingan desain dinding di lapangan dengan desain ulang, perbandingan deformasi lateral dinding di lapangan dengan deformasi lateral hasil pemodelan, jumlah debit air yang harus dipompa serta kebutuhan sumurnya, dan kekuatan sistem strutting dalam menahan beban.
Penelitian ini menggunakan program bantu PLAXIS untuk mendapatkan gaya momen, gaya geser, deformasi lateral dinding, dan gaya aksial yang terjadi pada strut. Hasil pembacaan deformasi lateral dinding dari inklinometer akan dibandingkan dengan deformasi lateral hasil dari pemodelan menggunakan PLAXIS. Persyaratan yang digunakan pada penelitian ini mengacu pada SNI 8460:2017 tentang Persyaratan Perancangan Geoteknik.
Hasil yang didapatkan dari analisis yang telah dilakukan adalah angka keamanan stabilitas tanah dasar galian untuk bahaya push-in failure berkisar antara 1,56 – 1,6 dan untuk bahaya basal heave berkisar antara 2,34 – 3,36. Keduanya memenuhi persyaratan, yaitu lebih dari 1,5. Perbandingan deformasi lateral dinding berdasarkan hasil inklinometer dengan hasil pemodelan cenderung cukup sama, namun untuk titik monitoring I-1 terdapat perbedaan sangat jauh. Hasil pembacaan deformasi untuk I-1 sebesar 112,4 mm sedangkan pada hasil pemodelan adalah 42,39 mm. Kemudian kekuatan batang strut berkisar antara 1100 kN – 1800 kN. Gaya aksial tekan yang ditahan batang strut lebih kecil dibandingkan kekuatan batang strut, sehingga kekuatan strut memenuhi persyaratan. Jumlah debit air yang harus dipompa adalah 2,84 m3/menit dengan kebutuhan jumlah sumurnya adalah 15 buah. Stabilitas dari dinding penahan tanah ini masih memenuhi persyaratan yang berlaku. Deformasi lateral berdasarkan pembacaan inklinometer yang melebihi persyaratan kemungkinan terjadi karena pemasangan strut yang tidak sesuai dengan perencanaan.
===================================================================================================
The basement planned for the MTH 27 Office Suites building project consist of 4 floors. The type of soil in this project is generally clay. The MTH 27 Office Suites project is surrounded by other commercial buildings. Diaphragm wall is the right type of retaining wall that suitable for this project. The lateral wall movements at the MTH 27 Office Suites project were monitored with an inclinometer and carried out with 4 points. The inclinometer point I-1 reached the largest lateral movement, which was 112,4 mm with 14 m depth. The deformation of point I-1 compared to the depth of the excavation reaches 0,8%, while the maximum deformation requirement is 0,5%. Further evaluation needs to be done to find out the stability of the retaining wall against the load that occurs. This study aims to determine the stability of the subgrade excavation, the comparison of the wall design in the field with the wall design based on the redesign, the comparison of the lateral deformation of the walls in the field with the lateral deformation of the modeling results, the amount of water discharge that must be pumped and the needs of the well, and the last is the strength of the strutting system.
This study was using PLAXIS to obtain the moment force, shear force, lateral wall deformation, and axial force that occurs in the strut. The lateral wall deformation from the inclinometer would be compared with the lateral deformation based on modeling results. The requirements used in this study refer to SNI 8460:2017 about Geotechnical Design Requirements.
The results obtained from the analysis that has been carried out are the safety factor of the stability of the subgrade excavation for the danger of push-in failure ranging from 1,56 – 1,6 and for the danger of basal heave ranging from 2,34 – 3,36. Both of them fit the requirements which are more than 1,5. The comparison of the lateral deformation of the wall based on the result of the inclinometer with the result of the modeling was quite similar, but for the deformation of the wall from point I-1, the result was very different from the result of the modeling. The deformation of the wall from point I-1 was 112,4 mm, while the modeling result was 42,39 mm. The strength of the strut ranging from 1100 kN – 1800 kN. The axial force that is held by the strut rod is less than the strength of the strut, so the strut strength fit the requirements. The amount of water discharge that must be pumped is 2,84 m3/minute with the required number of wells is 15 units. The stability of the retaining wall fits the requirements. Lateral deformation based on an inclinometer reading that exceeds the requirements may occur due to improper placement of the strut.

Item Type: Thesis (Undergraduate)
Uncontrolled Keywords: : diaphragm wall, inklinometer, PLAXIS, dewatering, strutting : diaphragm wall, inclinometer, PLAXIS, dewatering, strutting
Subjects: T Technology > TA Engineering (General). Civil engineering (General) > TA760+ Retaining walls
Divisions: Faculty of Vocational > Civil Infrastructure Engineering (D3)
Depositing User: Gheanifa Irma Yustika
Date Deposited: 11 Mar 2021 01:30
Last Modified: 04 Oct 2023 02:42
URI: http://repository.its.ac.id/id/eprint/84118

Actions (login required)

View Item View Item