Abstract
Karet adalah benda yang elastis dan banyak digunakan dalam banyak aplikasi karena deformasi elastis reversibelnya yang besar , karakteristik redaman dan penyerapan energi yang sangat baik. Karet dapat mengalami regangan besar tanpa deformasi plastis dan memulihkan bentuk awalnya setelah pelepasan beban. Bahan ini ideal untuk berbagai jenis aplikasi. Termasuk industri otomotif , perpipaan ,dan sebagai getaran isolator di banyak aplikasi lain. Salah satu sistem peredam yang biasa digunakan dalam mesin yaitu rubber mounting. Penelitian tentang rubber mounting diperlukan untuk mengetahui pengaruh rubber mounting terhadap getaran.
Dalam tugas akhir ini, penulis ingin menganalisis pengaruh variasi diameter rubber mount dan frekuensi kerja terhadap respon dinamis benda uji pada dual axis translational shaking table. Penelitian dilakukan menggunakan simulasi pada software MATLAB Simulink dan pengujian eksperimen dari Dual Axis Translational Shaking Table untuk dibandingkan. Simulasi dilakukan dengan menggunakan sofware MATLAB simulink untuk mengetahui respon dinamis dari sistem DTST. Simulasi dilakukan dengan menjalankan blok diagram yang telah dibuat dengan memasukkan nilai-nilai parameter yang dibutuhkan. Seluruh parameter dan gaya input yang bekerja pada sistem dimasukkan untuk melakukan simulasi. Proses yang dilakukan dengan memvariasikan frekuensi dan variasi diameter rubber mount. Selanjutnya pengujian eksperimen dilakukan dengan memasang massa benda uji berbentuk balok yang dipasang pada dual-axis translational shaking table (DTST). Di antara benda uji dan DTST diberi rubber mount dengan variasi diameter. Pengujian ini memvariasikan diameter rubber mount dan frekuensi kerja terhadap massa uji untuk menemukan output berupa respon dinamis percepatan.Terdapat variasi diameter rubber mounting sebesar 30mm,40mm,50mm. Dan variasi frekuensi kerja motor sebesar 7-15 Hz.
Hasil yang didapatkan dari penelitian ini adalah respon dinamis percepatan dari simulasi yang dilakukan dan didapatkan dari blok diagram software MATLAB Simulink dan juga respon dinamis percepatan dari eksperimen yang didapatkan dari accelerometer yang kemudian kemudian disambungkan pada oscilloscope untuk mendapatkan pembacaan pengukuran berupa grafik percepatan terhadap waktu. Data yang didapat dari oscilloscope kemudian dimasukkan kedalam komputer untuk kemudian dianalisis. Data yang didapatkan dari pengujian eksperimen akan dibandingkan dengan data yang didapatkan dari simulasi. Setelah dibandingkan dapat mengetahui nilai error dari perbedaan tersebut. Rata rata error yang didapat dibawah 10% dan rata rata error yang paling tinggi berada pada 9.57%. Perbedaan tersebut merupakan hal yang wajar dan dapat banyak factor yang mempengaruhi , salah satu contohnya adalah saat eksperimen adanya timbul noise, kurang presisi pemasangan bearing, dan juga tidak stabil saat mengatur voltage regulator yang dipakai. Dari data dan trend yang didapat dari eksperimen dan simulasi dapat disimpulkan bahwa dengan semakin tinggi frekuensi kerja dari motor dan juga semakin berat massa unbalance yang digunakan semakin tinggi percepatan yang dihasilkan. Pada saat memvariasikan peletakkan posisi probe accelerometer terlihat bahwa pada posisi P3 mempunyai nilai percepatan paling besar dikarenakan semakin jauh jarak dari pusat getarannya. Pada saat memvariasikan penggunaan diameter rubber mount , semakin besar diameter rubber mount yang digunakan semakin kecil percepatannya dikarenakan nilai koefisien redam yang semakin besar yang dapat mereduksi getaran.
=====================================================================================================
Rubber is an elastic material and is widely used in many applications due to its large reversible elastic deformation, excellent damping and energy absorption characteristics. Rubber can be subjected to large strains without plastic deformation and recover its original shape after unloading. This material is ideal for a wide variety of applications. Including the automotive industry, piping, and as a vibration isolator in many other applications. One of the damper systems commonly used in machines is rubber mounting. Research on rubber mounting is needed to determine the effect of rubber mounting on vibration.
In this final project, the author wants to analyze the effect of variations in rubber mount diameter and working frequency on the dynamic response of the specimen on a dual axis translational shaking table. The study was conducted using a simulation on the MATLAB Simulink software and experimental testing of the Dual Axis Translational Shaking Table for comparison. Simulations were carried out using MATLAB simulink software to determine the dynamic response of the DTST system. The simulation is done by running the block diagram that has been created by entering the required parameter values. All parameters and input forces acting on the system are entered to perform the simulation. The process is carried out by varying the frequency and diameter of the rubber mount. Furthermore, experimental testing was carried out by installing the mass of the test object in the form of a beam mounted on a dual-axis translational shaking table (DTST). Between the test object and the DTST was given a rubber mount with various diameters. This test varies the diameter of the rubber mount and the working frequency of the test mass to find the output in the form of an acceleration dynamic response. There are variations in the diameter of the rubber mounting of 30mm, 40mm, 50mm. And the variation of the motor working frequency is 7-15 Hz.
The results obtained from this study are the acceleration dynamic response from the simulation carried out and obtained from the block diagram of the MATLAB Simulink software and also the acceleration dynamic response from the experiment obtained from the accelerometer which is then connected to an oscilloscope to obtain a measurement reading in the form of a graph of acceleration against time. The data obtained from the oscilloscope is then entered into the computer for later analysis. The data obtained from the experimental test will be compared with the data obtained from the simulation. After being compared, you can find out the error value of the difference. The average error obtained is below 10% and the highest average error is at 9.57%. These differences are normal and can be influenced by many factors, one example of which is during the experiment noise arises, lacks precision in bearing installation, and is also unstable when adjusting the voltage regulator used. From the data and trends obtained from experiments and simulations, it can be concluded that the higher the working frequency of the motor and the heavier the unbalance mass used, the higher the acceleration generated. When varying the position of the accelerometer probe, it can be seen that the P3 position has the greatest acceleration value due to the farther distance from the center of the vibration. When varying the diameter of the rubber mount, the larger the diameter of the rubber mount used, the smaller the acceleration due to the greater damping coefficient value, which reduces vibration.
Item Type: | Thesis (Undergraduate) |
---|---|
Uncontrolled Keywords: | rubber mounting, massa unbalance, respon percepatan, dual-axis translational shaking table. rubber mounting, massa unbalance, acceleration response, dual-axis translational shaking table |
Subjects: | T Technology > TA Engineering (General). Civil engineering (General) > TA355 Vibration. T Technology > TJ Mechanical engineering and machinery > TJ230 Machine design |
Divisions: | Faculty of Industrial Technology and Systems Engineering (INDSYS) > Mechanical Engineering > 21201-(S1) Undergraduate Thesis |
Depositing User: | Muhammad Thaariq Rizki |
Date Deposited: | 29 Jul 2021 03:44 |
Last Modified: | 29 Jul 2021 03:44 |
URI: | http://repository.its.ac.id/id/eprint/84549 |