Ramadhani, Farid (2021) Studi Numerik Modifikasi Pompa Centrifugal Closed Impeller 80x65-250 Menjadi Semi Open Impeller. Undergraduate thesis, Institut Teknologi Sepuluh Nopember.
Text
10211710010109-Undergraduate_Thesis.pdf - Accepted Version Restricted to Repository staff only until 1 October 2023. Download (3MB) | Request a copy |
Abstract
Pompa sentrifugal mempunyai jenis impeller tertutup, pompa jenis ini memiliki kelebihan Head dan Efisisiensi yang cukup tinggi. Namun ada beberapa kekurangan yaitu mudah tersumbat dan lebih sulit melayani fluida cair yang kental. Dikarenakan dengan banyakanya permintaan pompa yang digunakan untuk melayani fluida cair yang mempunyai viskositas yang lebih tinggi dari air, maka pada tugas akhir ini dicoba untuk memodifikasi pompa closed impeller menjadi semi open impeller dengan variasi kemirigan blade.
Metode yang digunakan yaitu melakukan simulasi menggunakan computational fluid dynamics (CFD) dan Finite Element Method (FEM), yang bertujuan untuk mengetahui peforma dari pompa sebelum dan sesudah dimodifiaksi dan mengetahui kekuatan material yang digunakan. Pada proses penelitian digunakan software Solidworks untuk pemodelan dan melakukan simulasi terhadap pompa, untuk menghasilkan hasil yang akurat pada simulasi dilakukan validasi terhadap hasil simulasi pompa existing dengan data sheet dari perusahaan pembuat pompa, setelah dinyatakan valid maka dapat dilanjutkan memodifikasi bagian impeller pompa.
Pada simulasi menggunakan fluida air bersih hasil terbaik pada pompa dengan closed impeller dengan head 18.894 Meter, sedangkan pada simulasi menggunakan Nira hasil terbaik pada pompa dengan semi open impeller wrap angle blade 60° dengan head 19.040 Meter. Vonmises maksimal terdapat pada simulasi menggunakan fluida Nira sebesar 7.668E+06 N/m2 pada pompa semi open impeller wrap angle blade 45° maka pada impeller tidak mengalami deformasi dikarenakan tidak melebihi Yield Strength Point material FC 200.
======================================================================================================
Centrifugal pums have a closed impeller, this pump type has the advantages high efficiency and head. However, there are some disadvantages such as it easy to clog and more difdicult to handle high viscousity liquid. Due to a significant need for pump that can service liquid fluids with higer viscousity than water, this final project try to modify closed impeller into semi open impeller with variations wrap blade angle.
The method using computational fluid dynamics (CFD) and finite element method (FEM), which aims to determine the pump’s pefromance before and after modification and determine the strength of the material used. Solidworks software is used in the research process to mdel an simulate the pump. To ensure accurate results, the simulation is validated using simulation results from an existing pump and datah sheets from pump manufacturer. After being declared valid, it can be used to modify the pump impeller.
The greatest results in the clean water simulation are on a pump closed impeller with 18.894 Meter Head, where the best result in the nira simulation are on pump semi open impeller wrap angle blade of 60° with 19,040 Meter Head. Maximum vobmises were obtained in a simulation using nira fluid of 7.668E+06 N/m2 on a semi open impeller does not deform due to the impeller not exceending the yield strength point material FC 200.
Item Type: | Thesis (Undergraduate) |
---|---|
Uncontrolled Keywords: | modifikasi blade impeller, wrap angle, CFD, FEM, modification blade impeller, wrap angle, CFD, FEM |
Subjects: | T Technology > TJ Mechanical engineering and machinery > TJ919 Centrifugal pumps--Design and construction. |
Divisions: | Faculty of Vocational > Mechanical Industrial Engineering (D4) |
Depositing User: | Farid Ramadhani |
Date Deposited: | 09 Aug 2021 02:05 |
Last Modified: | 09 Aug 2021 02:05 |
URI: | http://repository.its.ac.id/id/eprint/85155 |
Actions (login required)
View Item |