Amrullah, Ahmad Musyfiq (2021) Hazard And Operability Study (HAZOP) Pada Unit Naptha Hydrotreater Berbasis Fuzzy Layer of Protection Analysis (FLOPA) Di Plant Refinery. Undergraduate thesis, Institut Teknologi Sepuluh Nopember.
Text
02311740000055-Undergraduate_Thesis.pdf - Accepted Version Restricted to Repository staff only until 1 October 2023. Download (3MB) | Request a copy |
Abstract
Unit Naptha hyrdrotreater merupakan salah satu proses dalam pengolahan heavy naptha dengan menggunakan prinsip hydrotreating untuk menghasilkan naptha. Equipment yang ada pada naptha hydrotreater adalah charge heater dan reboiler heater. Untuk mengetahui potensi bahaya yang terjadi dilakukan analisis HAZOP dan perhitungan LOPA untuk menentukan kecukupan lapisan perlindungan pada plant. Pada hasil penelitian analisis HAZOP yang telah dilakukan, menunjukan bahwa kedua equipment memiliki persentase 4,70% high risk. Perhitungan dengan metode LOPA didapatkan hasil berupa nilai PFD sebesar 1,05 dengan kategori NR sebanyak tujuh skenario, nilai PFD sebesar 0,105 dengan kategori SIL 0 sebanyak empat skenario, serta nilai PFD 0,0105 dengan kategori SIL 1 sebanyak empat skenario. Hasil SIL 1 pada LOPA menunjukan bahwa lapisan perlindungan yang ada belum cukup unutk mereduksi potensi bahaya yang terjadi, maka dilakukan penambahan SIS untuk mereduksi nilai LOPA. Penambahan SIS mampu mereduksi nilai SIL pada LOPA menjadi SIL 0 dengan nilai PFD sebesar 0.329, 0.33, dan 0.331. Untuk mempermudah pengerjaan LOPA, maka dilakukan penggunaan FLOPA dengan tipe mamdani, takagi sugeno, serta multi input multi output dan didapatkan hasil yang sama sebanyak 11 skenario dan 4 skenario dengan hasil berbeda untuk nilai SIL dengan perhitungan LOPA manual.
================================================================================================
Naphtha hydrotreater is one of the processes that treats heavy naphtha using the principle of hydrotreating to produce naphtha. The equipment of the naphtha hydroprocessing unit is a charge heater and a reboiler heater. HAZOP analysis and LOPA calculations are performed to determine the potential hazards that may arise to determine the adequacy of the plant's protective layer. As a result of the HAZOP analysis study conducted so far, both devices showed a high risk of 4.70%. Calculations using the LOPA method yielded a PFD value of 1.05 in the NR category for 7 scenarios, a SIL 0 category with a PFD value of 0.105 for 4 scenarios, and a SIL 1 category with a PFD value of 0.0105 for 4 scenarios. The results of SIL 1 for LOPA indicate that the existing layer of protection is not sufficient to reduce the potential risk arising, and the addition of SIS is done to reduce the value of LOPA. As a result of adding SIS, we were able to reduce the PFD value of LOPA to 0.329 for two scenarios and 0.33 and 0.331 for one scenario. To simplify the LOPA task, we used FLOPA with Mamdani type, Takagi Sugeno and multiple input multiple outputs, and obtained the same results in up to 11 scenarios and up to 4 scenarios with different results for SIL values by manual LOPA calculation.
Item Type: | Thesis (Undergraduate) |
---|---|
Uncontrolled Keywords: | HAZOP, LOPA, FLOPA, Naptha hydrotreater unit |
Subjects: | T Technology > T Technology (General) > T174.5 Technology--Risk assessment. |
Divisions: | Faculty of Industrial Technology and Systems Engineering (INDSYS) > Physics Engineering > 30201-(S1) Undergraduate Thesis |
Depositing User: | Ahmad Musyfiq Amrullah |
Date Deposited: | 19 Aug 2021 13:01 |
Last Modified: | 19 Aug 2021 13:01 |
URI: | http://repository.its.ac.id/id/eprint/87395 |
Actions (login required)
View Item |