Diagnosa Gangguan Hubung Singkat Belitan Stator Motor Induksi Menggunakan Sensor Eksternal Fluks dari Tiga Sumbu

Silalahi, Bolas Boy (2021) Diagnosa Gangguan Hubung Singkat Belitan Stator Motor Induksi Menggunakan Sensor Eksternal Fluks dari Tiga Sumbu. Undergraduate thesis, Institut Teknologi Sepuluh Nopember.

[thumbnail of 07111440000061-NON_DEGREE.pdf] Text
07111440000061-NON_DEGREE.pdf - Accepted Version
Restricted to Repository staff only until 1 October 2023.

Download (819kB) | Request a copy

Abstract

Penelitian tentang diagnosa gangguan hubung singkat pada belitan stator motor induksi ini bertujuan untuk membandingkan hasil analisis pengukuran fluks bocor dan arus stator dari tiga sumbu berbeda pada motor induksi. Metode penelitian dilakukan percobaan dan monitoring gangguan motor saat beroperasi. Percobaan dilakukan pada sebuah motor induksi 3 fasa yang belitannya sudah dimodifikasi sesuai data yang dibutuhkan. Percobaan dilakukan pada 2 kondisi berbeda yaitu kondisi motor
dengan kondisi normal dan kondisi motor dihubung singkatkan dengan kombinasi yang bisa diubah sesuai data yang diinginkan. Data yang diperoleh dari pengukuran menggunakan sensor fluks akan diolah menjadi 2 bagian frekuensi tinggi dan rendah. Selanjutnya data akan diubah ke bentuk Fast Fourier Transform untuk memetakan gelombang motor saat kondisi normal dan saat terjadi hubung singkat. Penelitian ini diharapkan dapat membandingkan efektifitas metode pengamatan dari 3 sumbu
berbeda pada kondisi motor yang sama untuk selanjutnya bisa berguna sebagai metode perbaikan kerusakan pada motor induksi yang disebabkan oleh hubung singkat.
=============================================================================================================
This research of diagnosis of short circuit interference in induction motor stator aims to compare the result of the analysis of the leakage flux and stator current measurements from three different axes on an induction motor. The research method was carried out by experimenting and monitoring motor interference while
operating. The experiment was carried out in 2 different conditions, normal motor condition and the motor condition was short circuited with a combination that could be changed according to desired data. The data obtained from measurements using a flux sensor will be processed into 2 parts high and low frequency. Then data will be converted into a Fast Fourier Transform to analyze the the motor wave during normal conditions and when a short circuit occurs. This research is expected to compare the effectiveness of the observation method from 3 different axes at the same motor condition which later can be usefull as a method of repairing demage to an induction motor caused by a short circuit.

Item Type: Thesis (Undergraduate)
Uncontrolled Keywords: Fast Fourier Transform, Hubung Singkat, Motor Induksi, Sensor Fluks, Flux Sensor, Induction Motor, Short Circuit
Subjects: T Technology > TK Electrical engineering. Electronics Nuclear engineering > TK2785 Electric motors, Induction.
Divisions: Faculty of Intelligent Electrical and Informatics Technology (ELECTICS) > Electrical Engineering > 20201-(S1) Undergraduate Thesis
Depositing User: BOLAS BOY SILALAHI
Date Deposited: 20 Aug 2021 01:25
Last Modified: 22 Aug 2021 03:12
URI: http://repository.its.ac.id/id/eprint/87792

Actions (login required)

View Item View Item